Quantifying the ultrastructure of carotid arteries using high-resolution micro-diffusion tensor imaging-comparison of intact versus open cut tissue

被引:14
|
作者
Shahid, Syed Salman [1 ,2 ,5 ]
Gaul, Robert T. [1 ,2 ]
Kerskens, Christian [3 ]
Flamini, Vittoria [4 ]
Lally, Caitriona [1 ,2 ]
机构
[1] Trinity Coll Dublin, Trinity Ctr Bioengn, Dublin 2, Ireland
[2] Trinity Coll Dublin, Sch Engn, Dept Mech & Mfg Engn, Dublin 2, Ireland
[3] Trinity Coll Dublin, Trinity Coll Inst Neurosci, Dublin 2, Ireland
[4] NYU, Tandon Sch Engn, Dept Mech & Aerosp Engn, Brooklyn, NY USA
[5] Emory Univ, Sch Med, Dept Neurol, Atlanta, GA 30322 USA
基金
欧洲研究理事会;
关键词
DTI; microstructure; fibre tractography; OPTICAL COHERENCE TOMOGRAPHY; ARTICULAR-CARTILAGE; MAGNETIC-RESONANCE; FIBER ORIENTATION; ELECTRON-MICROSCOPY; COLLAGEN STRUCTURE; SELF-DIFFUSION; VASCULAR WALL; NECROTIC CORE; WHITE-MATTER;
D O I
10.1088/1361-6560/aa9159
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Diffusion magnetic resonance imaging (dMRI) can provide insights into the microstructure of intact arterial tissue. The current study employed high magnetic field MRI to obtain ultra- high resolution dMRI at an isotropic voxel resolution of 117 mu m(3) in less than 2 h of scan time. A parameter selective single shell (128 directions) diffusion- encoding scheme based on Stejskel- Tanner sequence with echo- planar imaging (EPI) readout was used. EPI segmentation was used to reduce the echo time (TE) and to minimise the susceptibilityinduced artefacts. The study utilised the dMRI analysis with diffusion tensor imaging (DTI) framework to investigate structural heterogeneity in intact arterial tissue and to quantify variations in tissue composition when the tissue is cut open and flattened. For intact arterial samples, the region of interest base comparison showed significant differences in fractional anisotropy and mean diffusivity across the media layer (p < 0.05). For open cut flat samples, DTI based directionally invariant indices did not show significant differences across the media layer. For intact samples, fibre tractography based indices such as calculated helical angle and fibre dispersion showed near circumferential alignment and a high degree of fibre dispersion, respectively. This study demonstrates the feasibility of fast dMRI acquisition with ultra-high spatial and angular resolution at 7 T. Using the optimised sequence parameters, this study shows that DTI based markers are sensitive to local structural changes in intact arterial tissue samples and these markers may have clinical relevance in the diagnosis of atherosclerosis and aneurysm.