Cyclodextrin-based nonaqueous electrokinetic chromatography with UV and mass spectrometric detection: Application to the impurity profiling of amiodarone

被引:8
|
作者
Mol, Roelof [1 ]
de Jong, Gerhardus J. [1 ]
Somsen, Govert W. [1 ]
机构
[1] Univ Utrecht, NL-3508 TB Utrecht, Netherlands
关键词
cyclodextrins; drug analysis; impurity profiling; mass spectrometry; nonaqueous electrokinetic chromatography;
D O I
10.1002/elps.200800074
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The potential of nonaqueous electrokinetic chromatography (NAEKC) using cyclodextrins (CD) for the analysis of basic drugs and related compounds was evaluated. Both UV absorbance and mass spectrometric (MS) detection were employed. Addition of neutral CD to the NA background electrolyte did not significantly enhance the separation of a test mixture of basic drugs, and no change in selectivity was observed. In contrast, anionic single-isomer-sulfated CD strongly added to the selectivity of the NAEKC system inducing an improved resolution among the test compounds and increasing the migration time window. The applicability of the NAEKC system using anionic CD is demonstrated by the profiling of a sample of the drug amiodarone that bad been stored for 1 year at room temperature. Amiodarone is poorly soluble in water. NAEKC-UV analysis indicated the presence of at least seven impurities in the amiodarone sample. In order to identify these compounds, the NAEKC system was coupled directly to electrospray ionization (ESI) ion-trap MS. The total of detected impurities increased to 12 due to the added sensitivity and selectivity of MS detection. Based on the acquired MS/MS data, three sample constituents could be identified as 'known' impurities (British Pharmacopoeia), whereas for three unknown impurities molecular structures could be proposed. Estimated limits of detection for amiodarone using the NAEKC method were 1 mu g/mL with UV detection and 15 ng/mL with ESI-MS detection (full-scan). Based on relative responses, the impurity content of the stored drug substance was estimated to be 0.33 and 0.47% using NAEKC-UV and NAEKC-ESI-MS, respectively.
引用
收藏
页码:3575 / 3581
页数:7
相关论文
共 50 条
  • [1] Quenched phosphorescence detection in cyclodextrin-based electrokinetic chromatography
    Kuijt, J
    Roman, DA
    Ariese, F
    Brinkman, UAT
    Gooijer, C
    ANALYTICAL CHEMISTRY, 2002, 74 (19) : 5139 - 5145
  • [2] Impurity profiling of dexamphetamine sulfate by cyclodextrin-modified microemulsion electrokinetic chromatography
    Wongwan, Sudaporn
    Scriba, Gerhard K. E.
    ELECTROPHORESIS, 2010, 31 (17) : 3006 - 3011
  • [3] Electrokinetic Chromatography and Mass Spectrometric Detection Using Latex Nanoparticles as a Pseudostationary Phase
    Palmer, Christopher P.
    Hilder, Emily F.
    Quirino, Joselito P.
    Haddad, Paul R.
    ANALYTICAL CHEMISTRY, 2010, 82 (10) : 4046 - 4054
  • [4] Microemulsion electrokinetic chromatography with on-line atmospheric pressure photoionization mass spectrometric detection
    Himmelsbach, Markus
    Haunschmidt, Manuela
    Buchberger, Wolfgang
    Klampfl, Christian W.
    ANALYTICAL CHEMISTRY, 2007, 79 (04) : 1564 - 1568
  • [5] APPLICATION OF MICELLAR ELECTROKINETIC CHROMATOGRAPHY AND INDIRECT UV DETECTION FOR THE ANALYSIS OF FATTY-ACIDS
    ERIM, FB
    XU, X
    KRAAK, JC
    JOURNAL OF CHROMATOGRAPHY A, 1995, 694 (02) : 471 - 479
  • [6] Developments in the application of gas chromatography with atomic emission (plus mass spectrometric) detection
    Van Stee, L. L. R.
    Brinkman, U. A. Th.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1186 (1-2) : 109 - 122
  • [7] Buffer system for the separation of neutral and charged small molecules using micellar electrokinetic chromatography with mass spectrometric detection
    Goetzinger, WK
    Cai, H
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1079 (1-2) : 372 - 381
  • [8] Determination of furazolidone in animal feeds using liquid chromatography with UV and thermospray mass spectrometric detection
    McCracken, RJ
    Kennedy, DG
    JOURNAL OF CHROMATOGRAPHY A, 1997, 771 (1-2) : 349 - 354
  • [9] Application of cyclodextrin-based eluents in hydrophobic charge-induction chromatography: Elution of antibody at neutral pH
    Ren, Jun
    Yao, Peng
    Cao, Yaming
    Cao, Jian
    Zhang, Lijun
    Wang, Yuanqiang
    Jia, Lingyun
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1352 : 62 - 68
  • [10] Automated peak tracking for comprehensive impurity profiling in orthogonal liquid chromatographic separation using mass spectrometric detection
    Xue, G
    Bendick, AD
    Chen, R
    Sekulic, SS
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1050 (02) : 159 - 171