Robust Phased Array Non-Contact Vital Signs Monitoring in an Office Cubicle Setting

被引:0
|
作者
Hall, T. [1 ]
Tsay, J. [1 ]
Dominguez, G. [1 ]
Boothby, A. [1 ]
Das, V. [1 ]
Lopez, J. [1 ]
Nguyen, T. [2 ]
Banister, R. E. [2 ]
Lie, D. Y. C. [2 ]
机构
[1] Texas Tech Univ, Dept Elect & Comp Engn, Lubbock, TX 79409 USA
[2] Texas Tech Univ, Hlth Sci Ctr, Lubbock, TX 79409 USA
关键词
active antenna; beam-steering; Doppler Radar; e-health; homecare; noncontact vital signs monitoring; phased array; telemedicine; vital signs monitoring; remote monitoring;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Doppler-based non-contact vital signs (NCVS) sensor systems can monitor the heart and respiration rates without touching the patient, but the accuracy of the NCVS sensing can be degraded considerably by background clutters and movements artifacts from the monitored subject or other motions in the measurement environment. We have, therefore, developed a high directivity phased-array antenna NCVS system that can significantly increase the sensing accuracy and the monitoring range in a typical office cubicle setting. Depending on the position of the beam spot illuminated on the chest, our custom-made beam-steerable phased array NCVS system at 2.4GHz has demonstrated the accuracy of the heart rate monitoring to be within +/- 2 bpm (beat-per-minute) for 92.5%-99.2% of the time at 0.75m. As the monitoring range is extended to 1-1.5m with beam directly illuminating on the center of the chest, the heart rate monitoring accuracy remains within +/- 5 bpm above 78% of time. With more improvement, this phased array NCVS system should benefit patients considerably for telemedicine and remote monitoring, as the patient's vital signs can be monitored comfortably and continuously in both home and office settings, eventually capable of detecting potential sleep apnea and other respiratory or cardiovascular symptoms in real-time.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Extending the Range of Phased Array Non-Contact Vital Signs Monitoring in an Office Cubicle Setting
    Hall, T.
    Stout, C.
    Brewer, N.
    Dominguez, G.
    Tsay, J.
    Boothby, A.
    Das, V.
    Lopez, J.
    Nguyen, T.
    Banister, R. E.
    Lie, D. Y. C.
    2014 TEXAS SYMPOSIUM ON WIRELESS AND MICROWAVE CIRCUITS AND SYSTEMS (WMCS), 2014,
  • [2] A Phased Array Non-Contact Vital Signs Sensor with Automatic Beam Steering
    Hall, T.
    Nukala, B. T.
    Stout, C.
    Brewer, N.
    Tsay, J.
    Lopez, J.
    Banister, R. E.
    Nguyen, T.
    Lie, D. Y. C.
    2015 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM (IMS), 2015,
  • [3] DistancePPG: Robust non-contact vital signs monitoring using a camera
    Kumar, Mayank
    Veeraraghavan, Ashok
    Sabharwal, Ashutosh
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (05): : 1565 - 1588
  • [4] Long-Term Vital Sign Measurement Using a Non-Contact Vital Sign Sensor inside an Office Cubicle Setting
    Hall, T.
    Malone, N. A.
    Tsay, J.
    Lopez, J.
    Nguyen, T.
    Banister, R. E.
    Lie, D. Y. C.
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 4845 - 4848
  • [5] Non-contact vital signs monitoring in broiler chickens
    Hossain, Md. Shafkat
    Pramanik, Sourav Kumar
    Rahman, Atikur
    Ali, Shahin
    Islam, Shekh Md Mahmudul
    JOURNAL OF ENGINEERING-JOE, 2023, 2023 (11):
  • [6] Accurate and Continuous Non-Contact Vital Signs Monitoring Using Phased Array Antennas in a Clutter-Free Anechoic Chamber
    Boothby, A.
    Das, V.
    Lopez, J.
    Tsay, J.
    Nguyen, T.
    Banister, R. E.
    Lie, D. Y. C.
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 2862 - 2865
  • [7] A non-contact vital signs monitor
    Matthews, G
    Sudduth, B
    Burrow, M
    CRITICAL REVIEWS IN BIOMEDICAL ENGINEERING, 2000, 28 (1-2) : 173 - 178
  • [8] Non-Contact Sensor for Long-Term Continuous Vital Signs Monitoring: A Review on Intelligent Phased-Array Doppler Sensor Design
    Hall, Travis
    Lie, Donald Y. C.
    Nguyen, Tam Q.
    Mayeda, Jill C.
    Lie, Paul E.
    Lopez, Jerry
    Banister, Ron E.
    SENSORS, 2017, 17 (11):
  • [9] Non-Contact Vital Signs Monitoring Through Visible Light Sensing
    Abuella, Hisham
    Ekin, Sabit
    IEEE SENSORS JOURNAL, 2020, 20 (07) : 3859 - 3870
  • [10] Non-Contact Estimation at 60 GHz for Human Vital Signs Monitoring Using a Robust Optimization Algorithm
    Zhang, Ting
    Valerio, Guido
    Sarrazin, Julien
    Istrate, Dan
    2016 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM, 2016, : 1165 - 1166