Numerical study of base-isolated cylindrical liquid storage tanks using coupled acoustic-structural approach

被引:42
|
作者
Rawat, Aruna [1 ]
Matsagar, Vasant A. [1 ]
Nagpal, A. K. [1 ]
机构
[1] IIT Delhi, Dept Civil Engn, New Delhi 110016, India
关键词
Base-isolated; Base shear; Bi-directional; Coupled acoustic-structure; Finite element method; Liquid storage tank; Sloshing; FINITE-ELEMENT FORMULATIONS; FLUID-STRUCTURE INTERACTION; SEISMIC ANALYSIS; BE-FE; VIBRATION; BEHAVIOR; SYSTEM;
D O I
10.1016/j.soildyn.2019.01.005
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
A numerical study of the base-isolated ground-supported cylindrical liquid storage tank is carried out using finite element method (FEM). The coupled acoustic-structural (CAS) approach in the FEM is used for the analysis of the base-isolated tanks with rigid and flexible walls with varying parameters. Base isolation systems used in the present study are laminated rubber bearing (LRB) and friction pendulum system (FPS). The effects of aspect ratio (liquid height to radius) of the tank, and the isolation time period on the seismic response of the base-isolated tank is considered for investigation. For this study, the broad and slender tanks with three different isolation time periods are considered, which exhibit their relative flexibility. The sloshing displacement, base shear, hydrodynamic pressure, and bearing displacement responses are evaluated for three-dimensional (3-D) rigid and flexible tanks subjected to bi-directional components of earthquake ground motions. Moreover, the FE results are compared with the commonly used mechanical lumped-mass model of the base-isolated tank. The results show that as the time period of the isolator increases, i.e. increased flexibility, the base shear response is considerably reduced in both the rigid and flexible, broad and slender tanks. The reduction in the impulsive component causing base shear is more as compared to the convective (sloshing) component in the base-isolated tanks. The sloshing displacement increases with increase in the time period of the base isolation systems in both the rigid and flexible tanks. The impulsive hydrodynamic pressure along the tank wall is reduced with introduction of the isolation systems and the reduction is significantly more in case of the flexible isolators. The bearing displacement increases with increase in the time period of the isolation system adopted.
引用
收藏
页码:196 / 219
页数:24
相关论文
共 49 条
  • [31] Behavior of base-isolated liquid storage tanks under synthetic near-fault earthquake pulses
    Alhan, C.
    Guler, E.
    Gazi, H.
    LIFE-CYCLE OF ENGINEERING SYSTEMS: EMPHASIS ON SUSTAINABLE CIVIL INFRASTRUCTURE, 2017, : 2415 - 2419
  • [32] Damping enhancement of seismic isolated cylindrical liquid storage tanks using baffles
    Maleki, Abbas
    Ziyaeifar, Mansour
    ENGINEERING STRUCTURES, 2007, 29 (12) : 3227 - 3240
  • [33] Elastic and viscous bumpers for seismic mitigation of base-isolated liquid storage tanks in near-fault zones
    Bagheri, Saman
    Farajian, Mostafa
    JOURNAL OF VIBRATION AND CONTROL, 2023, 29 (17-18) : 4334 - 4343
  • [34] Seismic Control of Base-Isolated Liquid Storage Tanks Subjected to Bi-directional Strong Ground Motions
    Vern, Sourabh
    Shrimali, M. K.
    Bharti, S. D.
    Datta, T. K.
    Farsangi, Ehsan Noroozinejad
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2022, 47 (04) : 4511 - 4530
  • [35] Behavior of Base-Isolated Liquid Storage Tanks with Viscous Dampers under Historical Earthquakes Considering Superstructure Flexibility
    Guler, Elif
    Alhan, Cenk
    TURKISH JOURNAL OF CIVIL ENGINEERING, 2024, 35 (01): : 109 - 138
  • [36] Non-linear seismic response of base-isolated liquid storage tanks to bi-directional excitation
    Shrimali, MK
    Jangid, RS
    NUCLEAR ENGINEERING AND DESIGN, 2002, 217 (1-2) : 1 - 20
  • [37] Seismic Control of Base-Isolated Liquid Storage Tanks Subjected to Bi-directional Strong Ground Motions
    Sourabh Vern
    M. K. Shrimali
    S. D. Bharti
    T. K. Datta
    Ehsan Noroozinejad Farsangi
    Arabian Journal for Science and Engineering, 2022, 47 : 4511 - 4530
  • [38] Optimal design and seismic performance of base-isolated storage tanks using friction pendulum inerter systems
    Zhang, Li
    Guo, Ming
    li, Zhe
    Zhu, Lijie
    Meng, Yaolin
    STRUCTURES, 2022, 43 : 234 - 248
  • [39] Fragility Analysis of Base-Isolated Liquid Storage Tanks under Random Sinusoidal Base Excitation Using Generalized Polynomial Chaos Expansion-Based Simulation
    Saha, Sandip Kumar
    Sepahvand, Kheirollah
    Matsagar, Vasant A.
    Jain, Arvind K.
    Marburg, Steffen
    JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (10)
  • [40] Seismic response of base-isolated liquid storage tanks considering fluid-structure-soil interaction in time domain
    Cho, KH
    Kim, MK
    Lim, YM
    Cho, SY
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2004, 24 (11) : 839 - 852