Additive Manufacturing: A Comparative Analysis of Dimensional Accuracy and Skin Texture Reproduction of Auricular Prostheses Replicas

被引:31
作者
Unkovskiy, Alexey [1 ]
Spintzyk, Sebastian [2 ]
Axmann, Detlef [1 ]
Engel, Eva-Maria [1 ]
Weber, Heiner [1 ]
Huettig, Fabian [1 ]
机构
[1] Tuebingen Univ Hosp, Dept Prosthodont, Tubingen, Baden Wurttembe, Germany
[2] Tuebingen Univ Hosp, Med Mat Sci & Technol, Tubingen, Baden Wurttembe, Germany
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2019年 / 28卷 / 02期
关键词
Auricular prosthesis; digital workflow; facial prosthesis; fused deposition modeling; maxillofacial rehabilitation; rapid prototyping; RAPID PROTOTYPING TECHNOLOGIES; CAPTURING 3-DIMENSIONAL DATA; COMPUTERIZED-TOMOGRAPHY; DIGITAL TECHNOLOGIES; MODELS; FABRICATION; DESIGN; EAR; REQUIREMENTS; RELIABILITY;
D O I
10.1111/jopr.12681
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose The use of computer-aided design/computer-aided manufacturing (CAD/CAM) and additive manufacturing in maxillofacial prosthetics has been widely acknowledged. Rapid prototyping can be considered for manufacturing of auricular prostheses. Therefore, so-called prostheses replicas can be fabricated by digital means. The objective of this study was to identify a superior additive manufacturing method to fabricate auricular prosthesis replicas (APRs) within a digital workflow. Materials and Methods Auricles of 23 healthy subjects (mean age of 37.8 years) were measured in vivo with respect to an anthropometrical protocol. Landmarks were volumized with fiducial balls for 3D scanning using a handheld structured light scanner. The 3D CAD dataset was postprocessed, and the same anthropometrical measurements were made in the CAD software with the digital lineal. Each CAD dataset was materialized using fused deposition modeling (FDM), selective laser sintering (SLS), and stereolithography (SL), constituting 53 APR samples. All distances between the landmarks were measured on the APRs. After the determination of the measurement error within the five data groups (in vivo, CAD, FDM, SLS, and SL), the mean values were compared using matched pairs method. To this, the in vivo and CAD dataset were set as references. Finally, the surface structure of the APRs was qualitatively evaluated with stereomicroscopy and profilometry to ascertain the level of skin detail reproduction. Results The anthropometrical approach showed drawbacks in measuring the protrusion of the ear's helix. The measurement error within all groups of measurements was calculated between 0.20 and 0.28 mm, implying a high reproducibility. The lowest mean differences of 53 produced APRs were found in FDM (0.43%) followed by SLS (0.54%) and SL (0.59%)--compared to in vivo, and again in FDM (0.20%) followed by SL (0.36%) and SLS (0.39%)--compared to CAD. None of these values exceed the threshold of clinical relevance (1.5%); however, the qualitative evaluation revealed slight shortcomings in skin reproduction for all methods: reproduction of skin details exceeding 0.192 mm in depth was feasible. Conclusion FDM showed the superior dimensional accuracy and best skin surface reproduction. Moreover, digital acquisition and CAD postprocessing seem to play a more important role in the outcome than the additive manufacturing method used.
引用
收藏
页码:E460 / E468
页数:9
相关论文
共 46 条
[31]   Application of Computer-Assisted Design and Manufacturing-Fabricated Artificial Bone in the Reconstruction of Craniofacial Bone Defects [J].
Liang, Weiqiang ;
Yao, Yuanyuan ;
Huang, Zixian ;
Chen, Yuhong ;
Ji, Chenyang ;
Zhang, Jinming .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2016, 74 (07) :1499.e1-1499.e8
[32]  
Marafon PG, 2010, INT J PROSTHODONT, V23, P271
[33]   Regulatory Considerations in the Design and Manufacturing of Implantable 3D-Printed Medical Devices [J].
Morrison, Robert J. ;
Kashlan, Khaled N. ;
Flanangan, Colleen L. ;
Wright, Jeanne K. ;
Green, Glenn E. ;
Hollister, Scott J. ;
Weatherwax, Kevin J. .
CTS-CLINICAL AND TRANSLATIONAL SCIENCE, 2015, 8 (05) :594-600
[34]  
Murugesan K, 2012, J Indian Prosthodont Soc, V12, P16, DOI 10.1007/s13191-011-0103-8
[35]   Use of digital technologies for nasal prosthesis manufacturing [J].
Palousek, David ;
Rosicky, Jiri ;
Koutny, Daniel .
PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2014, 38 (02) :171-175
[36]   Creation and Utilization of a Digital Database for Nasal Prosthesis Models [J].
Reitemeier, Bernd ;
Goetzel, Bela ;
Schoene, Christine ;
Stockmann, Frank ;
Mueller, Rainer ;
Lexmanne, Jana ;
Meissner, Heike .
ONKOLOGIE, 2013, 36 (1-2) :7-11
[37]   Dimensional error in selective laser sintering and 3D-printing of models for craniomaxillary anatomy reconstruction [J].
Silva, Daniela Nascimento ;
De Oliveira, Marilia Gerhardt ;
Meurer, Eduardo ;
Meurer, Maria Ines ;
Lopes Da Silva, Jorge Vicente ;
Santa-Barbara, Ailton .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2008, 36 (08) :443-449
[38]   Rapid development of auricular prosthesis using CAD and rapid prototyping technologies [J].
Subburaj, K. ;
Nair, C. ;
Rajesh, S. ;
Meshram, S. M. ;
Ravi, B. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2007, 36 (10) :938-943
[39]   ACCURACY OF RAPID PROTOTYPE MODELS FOR HEAD AND NECK RECONSTRUCTION [J].
Taft, Robert M. ;
Kondor, Shayne ;
Grant, Gerald T. .
JOURNAL OF PROSTHETIC DENTISTRY, 2011, 106 (06) :399-408
[40]   Psychosocial and Quality of Life Outcomes of Prosthetic Auricular Rehabilitation with CAD/CAM Technology [J].
Tam, Chi Keung ;
McGrath, Colman Patrick ;
Ho, Samuel Mun Yin ;
Pow, Edmond Ho Nang ;
Luk, HenryWai Kuen ;
Cheung, Lim Kwong .
INTERNATIONAL JOURNAL OF DENTISTRY, 2014, 2014