Use of a Dedicated Pediatric CT Imaging Service Associated With Decreased Patient Radiation Dose

被引:15
|
作者
Borders, Heather L. [1 ,2 ,3 ]
Barnes, Courtney L. [2 ]
Parks, David C. [2 ]
Jacobsen, Jerilynn R. [2 ]
Zhou, Yong [2 ]
Hasselquist, Bruce E. [2 ]
Betz, Bradford W. [1 ,2 ,3 ]
机构
[1] Adv Radiol Serv PC, Grand Rapids, MI 49509 USA
[2] Spectrum Hlth Helen DeVos Childrens Hosp, Grand Rapids, MI USA
[3] Michigan State Univ, Coll Human Med, Grand Rapids, MI USA
关键词
Pediatric; CT; ALARA; radiation dose; COMPUTED-TOMOGRAPHY; REDUCTION;
D O I
10.1016/j.jacr.2011.12.027
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The growing use of CT as a diagnostic imaging tool has led to increased concern over radiation dose, particularly in pediatric patients. The ALARA concept has been popularized in dose reduction. ALARA supports the use of low-dose, pediatric-specific protocols. Strict adherence to low-dose protocols can be challenging, particularly in a high-volume radiology department that scans both pediatric and adult patients. The aim of this study was to determine whether the relocation of pediatric radiologic services from a combined high-volume pediatric and adult hospital to a children's hospital improves compliance with adjusted lower CT exposure parameters and thus the estimated effective dose of radiation delivered to pediatric patients. Methods: A retrospective review of abdominal and pelvic CT console dose and exposure parameter data on 495 patients from a combined pediatric and adult radiology department and subsequently 244 patients from a dedicated pediatric radiology department was performed. The console dose-length product was converted to estimated effective dose. Patients were divided into 1 of 8 weight categories for analysis. Results: A statistically significant decrease in the estimated effective dose for abdominal and pelvic CT studies was observed in all but one of the weight categories at the pediatric radiology department compared with the pediatric and adult radiology department. Conclusions: Imaging pediatric patients in a dedicated pediatric imaging department with dedicated pediatric CT technologists may result in greater compliance with pediatric protocols and significantly reduced patient dose. Conversely, greater scrutiny of compliance with pediatric dose-adjusted CT protocols may be necessary for departments that scan both children and adults.
引用
收藏
页码:340 / 343
页数:4
相关论文
共 50 条
  • [41] Radiation risk index for pediatric CT: a patient-derived metric
    Ehsan Samei
    Xiaoyu Tian
    W. Paul Segars
    Donald P. Frush
    Pediatric Radiology, 2017, 47 : 1737 - 1744
  • [42] Radiation dose from multidetector row CT imaging for acute stroke
    Mnyusiwalla, Anisa
    Aviv, Richard I.
    Symons, Sean P.
    NEURORADIOLOGY, 2009, 51 (10) : 635 - 640
  • [43] Radiation dose reduction in perfusion CT imaging of the brain: A review of the literature
    Othman, Ahmed E.
    Afat, Saif
    Brockmann, Marc A.
    Nikoubashman, Omid
    Brockmann, Carolin
    Nikolaou, Konstantin
    Wiesmann, Martin
    JOURNAL OF NEURORADIOLOGY, 2016, 43 (01) : 1 - 5
  • [44] Radiation dose from multidetector row CT imaging for acute stroke
    Anisa Mnyusiwalla
    Richard I. Aviv
    Sean P. Symons
    Neuroradiology, 2009, 51 : 635 - 640
  • [45] Does clinical indication play a role in CT radiation dose in pediatric patients?
    Triantopoulou, Sotiria
    Tsapaki, Virginia
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 41 : 53 - 57
  • [46] Strategies for Reducing Radiation Dose in CT for Pediatric Patients: How We Do It
    Anh-Vu Ngo
    Winant, Abbey J.
    Lee, Edward Y.
    Phillips, Grace S.
    SEMINARS IN ROENTGENOLOGY, 2018, 53 (02) : 124 - 131
  • [47] Asian consortium on radiation dose of pediatric cardiac CT (ASCI-REDCARD)
    Peter K. T. Hui
    Hyun Woo Goo
    Jing Du
    Janice J. K. Ip
    Suzu Kanzaki
    Young Jin Kim
    Supika Kritsaneepaiboon
    Oktavia Lilyasari
    Suvipaporn Siripornpitak
    Pediatric Radiology, 2017, 47 : 899 - 910
  • [48] Asian consortium on radiation dose of pediatric cardiac CT (ASCI-REDCARD)
    Hui, Peter K. T.
    Goo, Hyun Woo
    Du, Jing
    Ip, Janice J. K.
    Kanzaki, Suzu
    Kim, Young Jin
    Kritsaneepaiboon, Supika
    Lilyasari, Oktavia
    Siripornpitak, Suvipaporn
    PEDIATRIC RADIOLOGY, 2017, 47 (08) : 899 - 910
  • [49] Decreasing the effective radiation dose in pediatric craniofacial CT by changing head position
    Ryne A. Didier
    Anna A. Kuang
    Daniel L. Schwartz
    Nathan R. Selden
    Donna M. Stevens
    Dianna M. E. Bardo
    Pediatric Radiology, 2010, 40 : 1910 - 1917
  • [50] An assessment of Sri Lankan radiographer's knowledge and awareness of radiation protection and imaging parameters related to patient dose and image quality in computed tomography (CT)
    Hawarihewa, P. M.
    Satharasinghe, D.
    Amalaraj, T.
    Jeyasugiththan, J.
    RADIOGRAPHY, 2022, 28 (02) : 378 - 386