Use of a Dedicated Pediatric CT Imaging Service Associated With Decreased Patient Radiation Dose

被引:15
|
作者
Borders, Heather L. [1 ,2 ,3 ]
Barnes, Courtney L. [2 ]
Parks, David C. [2 ]
Jacobsen, Jerilynn R. [2 ]
Zhou, Yong [2 ]
Hasselquist, Bruce E. [2 ]
Betz, Bradford W. [1 ,2 ,3 ]
机构
[1] Adv Radiol Serv PC, Grand Rapids, MI 49509 USA
[2] Spectrum Hlth Helen DeVos Childrens Hosp, Grand Rapids, MI USA
[3] Michigan State Univ, Coll Human Med, Grand Rapids, MI USA
关键词
Pediatric; CT; ALARA; radiation dose; COMPUTED-TOMOGRAPHY; REDUCTION;
D O I
10.1016/j.jacr.2011.12.027
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The growing use of CT as a diagnostic imaging tool has led to increased concern over radiation dose, particularly in pediatric patients. The ALARA concept has been popularized in dose reduction. ALARA supports the use of low-dose, pediatric-specific protocols. Strict adherence to low-dose protocols can be challenging, particularly in a high-volume radiology department that scans both pediatric and adult patients. The aim of this study was to determine whether the relocation of pediatric radiologic services from a combined high-volume pediatric and adult hospital to a children's hospital improves compliance with adjusted lower CT exposure parameters and thus the estimated effective dose of radiation delivered to pediatric patients. Methods: A retrospective review of abdominal and pelvic CT console dose and exposure parameter data on 495 patients from a combined pediatric and adult radiology department and subsequently 244 patients from a dedicated pediatric radiology department was performed. The console dose-length product was converted to estimated effective dose. Patients were divided into 1 of 8 weight categories for analysis. Results: A statistically significant decrease in the estimated effective dose for abdominal and pelvic CT studies was observed in all but one of the weight categories at the pediatric radiology department compared with the pediatric and adult radiology department. Conclusions: Imaging pediatric patients in a dedicated pediatric imaging department with dedicated pediatric CT technologists may result in greater compliance with pediatric protocols and significantly reduced patient dose. Conversely, greater scrutiny of compliance with pediatric dose-adjusted CT protocols may be necessary for departments that scan both children and adults.
引用
收藏
页码:340 / 343
页数:4
相关论文
共 50 条
  • [21] Evaluation of radiation dose to pediatric models from whole body PET/CT imaging
    Mohammadi, Najmeh
    Akhlaghi, Parisa
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (04):
  • [22] Dose reduction in pediatric abdominal CT: use of iterative reconstruction techniques across different CT platforms
    Khawaja, Ranish Deedar Ali
    Singh, Sarabjeet
    Otrakji, Alexi
    Padole, Atul
    Lim, Ruth
    Nimkin, Katherine
    Westra, Sjirk
    Kalra, Mannudeep K.
    Gee, Michael S.
    PEDIATRIC RADIOLOGY, 2015, 45 (07) : 1046 - 1055
  • [23] Dose reduction in pediatric abdominal CT: use of iterative reconstruction techniques across different CT platforms
    Ranish Deedar Ali Khawaja
    Sarabjeet Singh
    Alexi Otrakji
    Atul Padole
    Ruth Lim
    Katherine Nimkin
    Sjirk Westra
    Mannudeep K. Kalra
    Michael S. Gee
    Pediatric Radiology, 2015, 45 : 1046 - 1055
  • [24] Model-based Iterative Reconstruction: Effect on Patient Radiation Dose and Image Quality in Pediatric Body CT
    Smith, Ethan A.
    Dillman, Jonathan R.
    Goodsitt, Mitchell M.
    Christodoulou, Emmanuel G.
    Keshavarzi, Nahid
    Strouse, Peter J.
    RADIOLOGY, 2014, 270 (02) : 526 - 534
  • [25] Optimal use of CT imaging in pediatric congenital cholesteatoma
    Kim, So Young
    Kim, Hyo-Sang
    Park, Min Hyun
    Lee, Jun Ho
    Oh, Seung Ha
    Chang, Sun
    Kim, Chong Sun
    Jung, Ah Young
    Kim, Young Ho
    AURIS NASUS LARYNX, 2017, 44 (03) : 266 - 271
  • [26] OPTIMIZATION OF RADIATION DOSE IN CT IMAGING: ESTABLISHING THE INSTITUTIONAL DIAGNOSTIC REFERENCE LEVELS AND PATIENT DOSE AUDITING
    Razali, Mohd Amir Syahmi Mat
    Ahmad, Muhamad Zabidi
    Shuaib, Ibrahim Lutfi
    Osman, Noor Diyana
    RADIATION PROTECTION DOSIMETRY, 2020, 188 (02) : 213 - 221
  • [27] Reduction of Radiation Dose in Pediatric Brain CT Is Not Associated with Missed Injuries or Delayed Diagnosis
    Arrangoiz, Rodrigo
    Opreanu, Razvan C.
    Mosher, Benjamin D.
    Morrison, Chet A.
    Stevens, Penny
    Kepros, John P.
    AMERICAN SURGEON, 2010, 76 (11) : 1255 - 1259
  • [28] Radiation Dose Reduction at Pediatric CT: Use of Low Tube Voltage and Iterative Reconstruction
    Nagayama, Yasunori
    Oda, Seitaro
    Nakaura, Takeshi
    Tsuji, Akinori
    Urata, Joji
    Furusawa, Mitsuhiro
    Utsunomiya, Daisuke
    Funama, Yoshinori
    Kidoh, Masafumi
    Yamashita, Yasuyuki
    RADIOGRAPHICS, 2018, 38 (05) : 1421 - +
  • [29] Evaluation of Impact of Factors Affecting CT Radiation Dose for Optimizing Patient Dose Levels
    Yang, Ching-Ching
    DIAGNOSTICS, 2020, 10 (10)
  • [30] Radiation Dose Metrics in CT: Assessing Dose Using the National Quality Forum CT Patient Safety Measure
    Keegan, Jillian
    Miglioretti, Diana L.
    Gould, Robert
    Donnelly, Lane F.
    Wilson, Nicole D.