Use of a Dedicated Pediatric CT Imaging Service Associated With Decreased Patient Radiation Dose

被引:15
|
作者
Borders, Heather L. [1 ,2 ,3 ]
Barnes, Courtney L. [2 ]
Parks, David C. [2 ]
Jacobsen, Jerilynn R. [2 ]
Zhou, Yong [2 ]
Hasselquist, Bruce E. [2 ]
Betz, Bradford W. [1 ,2 ,3 ]
机构
[1] Adv Radiol Serv PC, Grand Rapids, MI 49509 USA
[2] Spectrum Hlth Helen DeVos Childrens Hosp, Grand Rapids, MI USA
[3] Michigan State Univ, Coll Human Med, Grand Rapids, MI USA
关键词
Pediatric; CT; ALARA; radiation dose; COMPUTED-TOMOGRAPHY; REDUCTION;
D O I
10.1016/j.jacr.2011.12.027
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The growing use of CT as a diagnostic imaging tool has led to increased concern over radiation dose, particularly in pediatric patients. The ALARA concept has been popularized in dose reduction. ALARA supports the use of low-dose, pediatric-specific protocols. Strict adherence to low-dose protocols can be challenging, particularly in a high-volume radiology department that scans both pediatric and adult patients. The aim of this study was to determine whether the relocation of pediatric radiologic services from a combined high-volume pediatric and adult hospital to a children's hospital improves compliance with adjusted lower CT exposure parameters and thus the estimated effective dose of radiation delivered to pediatric patients. Methods: A retrospective review of abdominal and pelvic CT console dose and exposure parameter data on 495 patients from a combined pediatric and adult radiology department and subsequently 244 patients from a dedicated pediatric radiology department was performed. The console dose-length product was converted to estimated effective dose. Patients were divided into 1 of 8 weight categories for analysis. Results: A statistically significant decrease in the estimated effective dose for abdominal and pelvic CT studies was observed in all but one of the weight categories at the pediatric radiology department compared with the pediatric and adult radiology department. Conclusions: Imaging pediatric patients in a dedicated pediatric imaging department with dedicated pediatric CT technologists may result in greater compliance with pediatric protocols and significantly reduced patient dose. Conversely, greater scrutiny of compliance with pediatric dose-adjusted CT protocols may be necessary for departments that scan both children and adults.
引用
收藏
页码:340 / 343
页数:4
相关论文
共 50 条
  • [11] Variation in CT Pediatric Head Examination Radiation Dose: Results From a National Survey
    Kanal, Kalpana M.
    Graves, Janessa M.
    Vavilala, Monica S.
    Applegate, Kimberly E.
    Jarvik, Jeffrey G.
    Rivara, Frederick P.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (03) : W293 - W301
  • [12] Radiation dose associated with CT-guided drain placement for pediatric patients
    Cody J. Schwartz
    Ari J. Isaacson
    Lynn Ansley Fordham
    Marija Ivanovic
    J. Bradford Taylor
    Robert G. Dixon
    Pediatric Radiology, 2017, 47 : 718 - 723
  • [13] Patient-Specific Radiation Dose and Cancer Risk Estimation in Pediatric Chest CT: A Study in 30 Patients
    Lia, Xiang
    Samei, Ehsan
    Segars, W. Paul
    Sturgeon, Gregory M.
    Colsher, James G.
    Frush, Donald P.
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [14] What is the underestimation of radiation dose to the pediatric thyroid gland from contrast enhanced CT, if contrast medium uptake is not taken into account?
    Perisinakis, Kostas
    Pouli, Styliani
    Tzedakis, Antonis
    Spanakis, Kostas
    Hatzidakis, Adam
    Raissaki, Maria
    Damilakis, John
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 49 : 95 - 98
  • [15] Effect of staff training on radiation dose in pediatric CT
    Hojreh, Azadeh
    Weber, Michael
    Homolka, Peter
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (08) : 1574 - 1578
  • [16] Accuracy and Radiation Dose Reduction of Limited-Range CT in the Evaluation of Acute Appendicitis in Pediatric Patients
    Jin, Michael
    Sanchez, Thomas R.
    Lamba, Ramit
    Fananapazir, Ghaneh
    Corwin, Michael T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 209 (03) : 643 - 647
  • [17] Decreasing the effective radiation dose in pediatric craniofacial CT by changing head position
    Didier, Ryne A.
    Kuang, Anna A.
    Schwartz, Daniel L.
    Selden, Nathan R.
    Stevens, Donna M.
    Bardo, Dianna M. E.
    PEDIATRIC RADIOLOGY, 2010, 40 (12) : 1910 - 1917
  • [18] CT Radiation Dose Reduction in Robot-assisted Pediatric Spinal Surgery
    Sensakovic, William F.
    O'Dell, M. Cody
    Agha, Ali
    Woo, Raymund
    Varich, Laura
    SPINE, 2017, 42 (07) : E417 - E424
  • [19] Dedicated breast CT: radiation dose for circle-plus-line trajectory
    Vedantham, Srinivasan
    Shi, Linxi
    Karellas, Andrew
    Noo, Frederic
    MEDICAL PHYSICS, 2012, 39 (03) : 1530 - 1541
  • [20] Experimental measurement of radiation dose in a dedicated breast CT system
    申善威
    王燕芳
    舒航
    唐晓
    魏存峰
    宋玉收
    史戎坚
    魏龙
    Chinese Physics C, 2014, (03) : 93 - 99