Use of a Dedicated Pediatric CT Imaging Service Associated With Decreased Patient Radiation Dose

被引:15
|
作者
Borders, Heather L. [1 ,2 ,3 ]
Barnes, Courtney L. [2 ]
Parks, David C. [2 ]
Jacobsen, Jerilynn R. [2 ]
Zhou, Yong [2 ]
Hasselquist, Bruce E. [2 ]
Betz, Bradford W. [1 ,2 ,3 ]
机构
[1] Adv Radiol Serv PC, Grand Rapids, MI 49509 USA
[2] Spectrum Hlth Helen DeVos Childrens Hosp, Grand Rapids, MI USA
[3] Michigan State Univ, Coll Human Med, Grand Rapids, MI USA
关键词
Pediatric; CT; ALARA; radiation dose; COMPUTED-TOMOGRAPHY; REDUCTION;
D O I
10.1016/j.jacr.2011.12.027
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The growing use of CT as a diagnostic imaging tool has led to increased concern over radiation dose, particularly in pediatric patients. The ALARA concept has been popularized in dose reduction. ALARA supports the use of low-dose, pediatric-specific protocols. Strict adherence to low-dose protocols can be challenging, particularly in a high-volume radiology department that scans both pediatric and adult patients. The aim of this study was to determine whether the relocation of pediatric radiologic services from a combined high-volume pediatric and adult hospital to a children's hospital improves compliance with adjusted lower CT exposure parameters and thus the estimated effective dose of radiation delivered to pediatric patients. Methods: A retrospective review of abdominal and pelvic CT console dose and exposure parameter data on 495 patients from a combined pediatric and adult radiology department and subsequently 244 patients from a dedicated pediatric radiology department was performed. The console dose-length product was converted to estimated effective dose. Patients were divided into 1 of 8 weight categories for analysis. Results: A statistically significant decrease in the estimated effective dose for abdominal and pelvic CT studies was observed in all but one of the weight categories at the pediatric radiology department compared with the pediatric and adult radiology department. Conclusions: Imaging pediatric patients in a dedicated pediatric imaging department with dedicated pediatric CT technologists may result in greater compliance with pediatric protocols and significantly reduced patient dose. Conversely, greater scrutiny of compliance with pediatric dose-adjusted CT protocols may be necessary for departments that scan both children and adults.
引用
收藏
页码:340 / 343
页数:4
相关论文
共 50 条
  • [1] Pediatric CT: Strategies to Lower Radiation Dose
    Zacharias, Claudia
    Alessio, Adam M.
    Otto, Randolph K.
    Iyer, Ramesh S.
    Philips, Grace S.
    Swanson, Jonathan O.
    Thapa, Mahesh M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (05) : 950 - 956
  • [2] PATIENT DOSE MANAGEMENT IN CT, SPECT/CT AND PET/CT IMAGING
    Mattsson, Soren
    Soderberg, Marcus
    MEDICAL PHYSICS IN THE BALTIC STATES, 2010, (02): : 18 - 23
  • [3] Lower radiation exposure from body CT imaging for trauma at a dedicated pediatric hospital
    Sharp, Nicole E.
    Svetanoff, Wendy J.
    Alemayehu, Hanna
    Desai, Amita
    Raghavan, Maneesha U.
    Sharp, Susan W.
    Brown, James C.
    Rivard, Douglas C.
    St. Peter, Shawn
    Holcomb, George W., III
    JOURNAL OF PEDIATRIC SURGERY, 2014, 49 (12) : 1843 - 1845
  • [4] Practical Strategies to Reduce Pediatric CT Radiation Dose
    Nelson, Thomas R.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2014, 11 (03) : 292 - 299
  • [5] The influence of patient positioning on radiation dose in CT imaging: A narrative review
    Al-Hayek, Yazan
    Zheng, Xiaoming
    Hayre, Christopher
    Spuur, Kelly
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2022, 53 (04) : 737 - 747
  • [6] Patient-specific Radiation Dose and Cancer Risk for Pediatric Chest CT
    Li, Xiang
    Samei, Ehsan
    Segars, W. Paul
    Sturgeon, Gregory M.
    Colsher, James G.
    Frush, Donald P.
    RADIOLOGY, 2011, 259 (03) : 862 - 874
  • [7] The effect of iodine uptake on radiation dose absorbed by patient tissues in contrast enhanced CT imaging: Implications for CT dosimetry
    Perisinakis, Kostas
    Tzedakis, Antonis
    Spanakis, Kostas
    Papadakis, Antonios E.
    Hatzidakis, Adam
    Damilakis, John
    EUROPEAN RADIOLOGY, 2018, 28 (01) : 151 - 158
  • [8] Dedicated breast CT: Radiation dose and image quality evaluation
    Boone, JM
    Nelson, TR
    Lindfors, KK
    Seibert, JA
    RADIOLOGY, 2001, 221 (03) : 657 - 667
  • [9] Radiation dose associated with CT-guided drain placement for pediatric patients
    Schwartz, Cody J.
    Isaacson, Ari J.
    Fordham, Lynn Ansley
    Ivanovic, Marija
    Taylor, J. Bradford
    Dixon, Robert G.
    PEDIATRIC RADIOLOGY, 2017, 47 (06) : 718 - 723
  • [10] Experimental measurement of radiation dose in a dedicated breast CT system
    Shen Shan-Wei
    Wang Yan-Fang
    Shu Hang
    Tang Xiao
    Wei Cun-Feng
    Song Yu-Shou
    Shi Rong-Jian
    Wei Long
    CHINESE PHYSICS C, 2014, 38 (03)