Cell membrane water exchange effects in prostate DCE-MRI

被引:31
|
作者
Li, Xin [1 ]
Priest, Ryan A. [2 ,3 ]
Woodward, William J. [1 ]
Siddiqui, Faisal [2 ,3 ]
Beer, Tomasz M. [4 ,6 ]
Garzotto, Mark G. [5 ,7 ]
Rooney, William D. [1 ]
Springer, Charles S., Jr. [1 ,6 ]
机构
[1] Oregon Hlth & Sci Univ, Adv Imaging Res Ctr, WM Keck Fdn High Field MRI Lab, Portland, OR 97239 USA
[2] Oregon Hlth & Sci Univ, Sch Med, Portland, OR 97239 USA
[3] Oregon Hlth & Sci Univ, Dept Radiol, Portland, OR 97239 USA
[4] Oregon Hlth & Sci Univ, Dept Hematol Oncol, Portland, OR 97239 USA
[5] Oregon Hlth & Sci Univ, Dept Urol, Portland, OR 97239 USA
[6] Oregon Hlth & Sci Univ, Knight Canc Inst, Portland, OR 97239 USA
[7] Portland VA Med Ctr, Portland, OR 97239 USA
关键词
Dynamic-Contrast-Enhanced; Water exchange; Contrast reagent; Prostate cancer; CONTRAST-ENHANCED-MRI; CR BOLUS-TRACKING; SHUTTER-SPEED; BENIGN; CANCER; DIFFERENTIATION;
D O I
10.1016/j.jmr.2012.03.019
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Prostate Dynamic-Contrast-Enhanced (DCE) MRI often exhibits fast and extensive global contrast reagent (CR) extravasation - measured by K-trans, a pharmacokinetic parameter proportional to its rate. This implies that the CR concentration [CR] is high in the extracellular, extravascular space (EES) during a large portion of the DCE-MRI study. Since CR is detected indirectly, through water proton signal change, the effects of equilibrium transcytolemmal water exchange may be significant in the data and thus should be admitted in DCE-MRI pharmacokinetic modeling. The implications for parameter values were investigated through simulations, and analyses of actual prostate data, with different models. Model parameter correlation and precision were also explored. A near-optimal version of the exchange-sensitized model was found. Our results indicate that Delta K-trans (the K-trans difference returned by this version and a model assuming exchange to be effectively infinitely fast) may be a very useful biomarker for discriminating malignant from benign prostate tissue. Using an exchange-sensitized model, we find that the mean intracellular water lifetime (tau(i)) - an exchange measure - can be meaningfully mapped for the prostate. Our results show prostate glandular zone differences in tau(i) values. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:77 / 85
页数:9
相关论文
共 50 条
  • [1] Feasibility of shutter-speed DCE-MRI for improved prostate cancer detection
    Li, Xin
    Priest, Ryan A.
    Woodward, William J.
    Tagge, Ian J.
    Siddiqui, Faisal
    Huang, Wei
    Rooney, William D.
    Beer, Tomasz M.
    Garzotto, Mark G.
    Springer, Charles S., Jr.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (01) : 171 - 178
  • [2] Relative sensitivities of DCE-MRI pharmacokinetic parameters to arterial input function (AIF) scaling
    Li, Xin
    Cai, Yu
    Moloney, Brendan
    Chen, Yiyi
    Huang, Wei
    Woods, Mark
    Coakley, Fergus V.
    Rooney, William D.
    Garzotto, Mark G.
    Springer, Charles S., Jr.
    JOURNAL OF MAGNETIC RESONANCE, 2016, 269 : 104 - 112
  • [3] Evaluation of the effect of transcytolemmal water exchange analysis for therapeutic response assessment using DCE-MRI: a comparison study
    Wang, Chunhao
    Subashi, Ergys
    Liang, Xiao
    Yin, Fang-Fang
    Chang, Zheng
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (13): : 4763 - 4780
  • [4] Analysis of Prostate DCE-MRI Comparison of Fast Exchange Limit and Fast Exchange Regimen Pharmacokinetic Models in the Discrimination of Malignant From Normal Tissue
    Lowry, Martin
    Zelhof, Bashar
    Liney, Gary P.
    Gibbs, Peter
    Pickles, Martin D.
    Turnbull, Lindsay W.
    INVESTIGATIVE RADIOLOGY, 2009, 44 (09) : 577 - 584
  • [5] Performance of Ultrafast DCE-MRI for Diagnosis of Prostate Cancer
    Chatterjee, Aritrick
    He, Dianning
    Fan, Xiaobing
    Wang, Shiyang
    Szasz, Teodora
    Yousuf, Ambereen
    Pineda, Federico
    Antic, Tatjana
    Mathew, Melvy
    Karczmar, Gregory S.
    Oto, Aytekin
    ACADEMIC RADIOLOGY, 2018, 25 (03) : 349 - 358
  • [6] Evaluation of orbital lesions with DCE-MRI: a literature review
    Ang, Terence
    Juniat, Valerie
    Patel, Sandy
    Selva, Dinesh
    ORBIT-THE INTERNATIONAL JOURNAL ON ORBITAL DISORDERS-OCULOPLASTIC AND LACRIMAL SURGERY, 2024, 43 (03): : 408 - 416
  • [7] A novel anthropomorphic flow phantom for the quantitative evaluation of prostate DCE-MRI acquisition techniques
    Knight, Silvin P.
    Browne, Jacinta E.
    Meaney, James F.
    Smith, David S.
    Fagan, Andrew J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (20): : 7466 - 7483
  • [8] Automatic Detection and Quantitative DCE-MRI Scoring of Prostate Cancer Aggressiveness
    Parra, Nestor Andres
    Pollack, Alan
    Chinea, Felix M.
    Abramowitz, Matthew C.
    Marples, Brian
    Munera, Felipe
    Castillo, Rosa
    Kryvenko, Oleksandr N.
    Punnen, Sanoj
    Stoyanova, Radka
    FRONTIERS IN ONCOLOGY, 2017, 7
  • [9] A comparison of arterial spin labeling perfusion MRI and DCE-MRI in human prostate cancer
    Cai, Wenchao
    Li, Feiyu
    Wang, Jing
    Du, Huarui
    Wang, Xiaoying
    Zhang, Jue
    Fang, Jing
    Jiang, Xuexiang
    NMR IN BIOMEDICINE, 2014, 27 (07) : 817 - 825
  • [10] DCE MRI of prostate cancer
    Berman, Rose M.
    Brown, Anna M.
    Chang, Silvia D.
    Sankineni, Sandeep
    Kadakia, Meet
    Wood, Bradford J.
    Pinto, Peter A.
    Choyke, Peter L.
    Turkbey, Baris
    ABDOMINAL RADIOLOGY, 2016, 41 (05) : 844 - 853