Effects of insertion depth of cochlear implant electrodes upon speech perception

被引:103
作者
Yukawa, K
Cohen, L
Blamey, P
Pyman, B
Tungvachirakul, V
O'Leary, S
机构
[1] Univ Melbourne, Royal Victorian Eye & Ear Hosp, Dept Otolaryngol, Melbourne, Vic, Australia
[2] CRC Cochlear Implant & Hearing Aid Innovat, Melbourne, Vic, Australia
[3] Tokyo Med Univ, Dept Otolaryngol, Tokyo, Japan
关键词
cochlear implant; speech perception; electrodes;
D O I
10.1159/000077267
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objective: To investigate whether the insertion depth of a cochlear implant array affects postoperative speech perception. Design: The subjects were 48 postlingually deaf adults who received either the Nucleus 22 or the Nucleus 24 cochlear implant with a straight array. A postoperative radiograph of the cochlear electrode was used to estimate insertion depth, as either the angle of the electrode tip (angle) or the intracochlear length of the electrode (length). Other estimates of insertion depth included the numbers of active electrodes and channels used by the speech processor. Electrode depth, together with the duration of deafness, hearing aid usage, pre-operative speech perception score and pre-operative pure-tone averages were independent variables in a forward stepwise multiple regression analysis, where the dependent variables were postoperative CNC words and CNC phonemes. Results: Duration of deafness and insertion depth (angle, insertion length or active electrodes) were the predictive variables for CNC words or CNC phonemes. Angle was the best 'depth-related' predictor of postoperative speech perception. An even clearer relationship was found between CUNY sentences in noise and angle, in a subset of 26 patients. Conclusion: Depth of electrode insertion affects postoperative speech perception. Copyright (C) 2004 S. Karger AG, Basel.
引用
收藏
页码:163 / 172
页数:10
相关论文
共 36 条
  • [1] Battmer R D, 1995, Ann Otol Rhinol Laryngol Suppl, V166, P185
  • [2] Blamey P, 1996, Audiol Neurootol, V1, P293
  • [3] BLAMEY P, 1997, AM J OTOL, V18, P11
  • [4] Blamey P J, 1995, Ann Otol Rhinol Laryngol Suppl, V166, P220
  • [5] FACTORS PREDICTING POSTOPERATIVE SENTENCE SCORES IN POSTLINGUISTICALLY DEAF ADULT COCHLEAR IMPLANT PATIENTS
    BLAMEY, PJ
    PYMAN, BC
    CLARK, GM
    DOWELL, RC
    GORDON, M
    BROWN, AM
    HOLLOW, RD
    [J]. ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1992, 101 (04) : 342 - 348
  • [6] Bredberg G, 1995, Ann Otol Rhinol Laryngol Suppl, V166, P256
  • [7] Cohen L T, 1996, Audiol Neurootol, V1, P265
  • [8] Spatial spread of neural excitation in cochlear implant recipients: comparison of improved ECAP method and psychophysical forward masking
    Cohen, LT
    Richardson, LM
    Saunders, E
    Cowan, RSC
    [J]. HEARING RESEARCH, 2003, 179 (1-2) : 72 - 87
  • [9] Cohen LT, 1996, AM J OTOL, V17, P859
  • [10] Simulating the effect of cochlear-implant electrode insertion depth on speech understanding
    Dorman, MF
    Loizou, PC
    Rainey, D
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 102 (05) : 2993 - 2996