A simple and sensitive HPLC-FL method for simultaneous determination of angiotensin II receptor antagonists in human plasma

被引:3
作者
Castro e Souza, Mateus Araujo [1 ]
Araujo Reis, Naialy Fernandes [1 ]
da Silva Leite, Isabella Marques [1 ]
Gloria, Maria Beatriz A. [1 ]
Pianetti, Gerson Antonio [1 ]
Parreiras Martins, Maria Auxiliadora [1 ]
Placido de Oliveira Pacheco, Isabella Cristina [1 ]
Fernandes, Christian [1 ]
机构
[1] Univ Fed Minas Gerais, Fac Farm, Dept Prod Farmaceut, Av Pres Antonio Carlos 6627, BR-31270901 Belo Horizonte, MG, Brazil
关键词
Angiotensin receptor blockers; Liquid chromatography; Fluorescence; Protein precipitation; Microextraction by packed sorbent; Liquid-liquid extraction; ANTIHYPERTENSIVE DRUGS; LIQUID-CHROMATOGRAPHY; SIMULTANEOUS QUANTIFICATION; METABOLITES; MS/MS;
D O I
10.1016/j.jpba.2020.113403
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Angiotensin II receptor antagonists are one of the most widely used classes of antihypertensive drugs. In this study, an HPLC fluorescence method after protein precipitation (PPT) extraction was developed and validated for determination of olmesartan, losartan, irbesartan, and valsartan in human plasma. The separation was carried out on a Luna cyano (250 x 4.6 mm i.d.; 5 mu m particle size) column and the mobile phase was composed of acetonitrile and 0.1 % phosphoric acid in gradient elution, at a flow rate of 1.2 mL min(-1). A PPT method was optimized by a two-level factorial design with triplicate at the central point. The parameters that could affect the extraction (sample volume and acetonitrile/plasma volume ratio) were evaluated and the method was compared to microextraction by packed sorbent (MEPS) and liquid-liquid extraction (LLE). The developed method allowed the simultaneous quantification of the analytes employing a simple and cheap sample preparation method and a short chromatographic run (13 min). This method was fully validated showing selectivity, precision, accuracy, and linearity over the range of 25.0-1500.0 ng mL(-1) for olmesartan and valsartan, 25.0-2500.0 ng mL(-1) for irbesartan, and 35.0-2500.0 ng mL(-1) for losartan. Finally, the method was successfully applied in the analysis of human plasma from volunteers. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:8
相关论文
共 18 条
[1]  
[Anonymous], 2013, GLOBAL BRIEF HYPERTE
[2]   Characteristics of contemporary patients with hypertension and coronary artery disease [J].
Cooper-DeHoff, RM ;
Handberg, EM ;
Cohen, J ;
Kowey, P ;
Messerli, FH ;
Manci, G ;
Cangiano, JL ;
Gaxiola, E ;
Garcia-Barreto, D ;
Hewkin, AC ;
Pepine, CJ .
CLINICAL CARDIOLOGY, 2004, 27 (10) :571-576
[3]   UHPLC-MS/MS method with protein precipitation extraction for the simultaneous quantification of ten antihypertensive drugs in human plasma from resistant hypertensive patients [J].
De Nicolo, Amedeo ;
Avataneo, Valeria ;
Rabbia, Franco ;
Bonifacio, Gabriele ;
Cusato, Jessica ;
Tomasello, Cristina ;
Perlo, Elisa ;
Mulatero, Paolo ;
Veglio, Franco ;
Di Perri, Giovanni ;
D'Avolio, Antonio .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 129 :535-541
[4]   An LC-MS assay for the screening of cardiovascular medications in human samples [J].
Dias, Eduardo ;
Hachey, Brian ;
McNaughton, Candace ;
Nian, Hui ;
Yu, Chang ;
Straka, Brittany ;
Brown, Nancy J. ;
Caprioli, Richard M. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 937 :44-53
[5]   Spectrofluorimetric method for determination of some angiotensin II receptor antagonists [J].
El-Shaboury, Salwa R. ;
Hussein, Samiha A. ;
Mohamed, Niveen A. ;
El-Sutohy, Mohamed M. .
JOURNAL OF PHARMACEUTICAL ANALYSIS, 2012, 2 (01) :12-18
[6]   Validated quantitation of angiotensin II receptor antagonists (ARA-II) in human plasma by liquid-chromatography-tandem mass Spectrometry using minimum sample clean-up and lnvestigation of lon suppression [J].
Ferreirs, Nerea ;
Dresen, Sebastian ;
Alonso, Rosa Maria ;
Weinmann, Wolfgang .
THERAPEUTIC DRUG MONITORING, 2007, 29 (06) :824-834
[7]  
Food and Drug Administration, 2018, BIOAN METH VAL GUID, P1
[8]   Fast screening method for the determination of angiotensin II receptor antagonists in human plasma by high-performance liquid chromatography with fluorimetric detection [J].
González, L ;
López, JA ;
Alonso, RM ;
Jiménez, RM .
JOURNAL OF CHROMATOGRAPHY A, 2002, 949 (1-2) :49-60
[9]   Development of an LC-MS/MS method for the quantitation of 55 compounds prescribed in combined cardiovascular therapy [J].
Gonzalez, Oskar ;
Maria Alonso, Rosa ;
Ferreiros, Nerea ;
Weinmann, Wolfgang ;
Zimmermann, Ralf ;
Dresen, Sebastian .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (3-4) :243-252
[10]   Method Validation for Simultaneous Quantification of Olmesartan and Hydrochlorothiazide in Human Plasma Using LC-MS/MS and Its Application Through Bioequivalence Study in Healthy Volunteers [J].
Kumar, Arvind ;
Dwivedi, Surya Prakash ;
Prasad, Tulika .
FRONTIERS IN PHARMACOLOGY, 2019, 10