Numerical parametric study of a waveguide-based ultrasonic sensor for telemetry in a sodium-cooled fast reactor

被引:0
作者
Le Bourdais, Florian [1 ]
Recoquillay, Arnaud [1 ]
Imperiale, Alexandre [1 ]
Kim, Hoe-Woong [2 ]
Joo, Young-Sang [2 ,3 ]
Park, Sang-Jin [2 ,3 ]
Eoh, Jaehyuk [2 ]
机构
[1] French Alternat Energies & Nucl Energy Commission, Lab Integrat Syst & Technol CM List, F-91191 Gif Sur Yvette, France
[2] Korea Atom Energy Res Inst, Versatile Syst Technol Dev Div, 989-111 Daedeok Daero, Daejeon 34057, South Korea
[3] Univ Sci & Technol, Dept Adv Nucl Syst Engn, 217 Gajeong Ro, Daejeon 34113, South Korea
关键词
Sodium fast reactor; Liquid sodium; Telemetry; Acoustics; Guided waves; Piezoelectric transducer; Numerical simulation; Finite elements; Semi-analytical modeling; Parametric study; INSPECTION;
D O I
10.1016/j.nucengdes.2020.110688
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This paper presents a collaborative work that started out under the framework of the Generation IV International Forum regarding ultrasound telemetry in sodium-cooled fast reactors. The liquid sodium environment imposes harsh constraints on immersed transducers for telemetry. An alternative approach consists in locating a transducer outside of the reactor core and exciting guided waves that are conducted by a waveguide inside the liquid sodium from where they radiate inside the reactor and can be used for telemetry and associated inspections. This work presents a numerical method coupling the propagation of elastic guided waves in long waveguides with a liquid environment and applies it to conduct a parametric study on several waveguide designs. The simulated results are compared to data from real waveguides obtained in a water tank, carried out with 9 sensors, in order to cover a large design space and ensure the validity of the modeling approach. Good agreement is observed with respect to the main measured quantities. The limits of the developed model are discussed with the help of these results. In particular, variations linked to untracked experimental parameters are shown to have an impact on results.
引用
收藏
页数:10
相关论文
共 22 条
  • [1] [Абдеррахим Хамид Аит Abderrahim Hamid Ait], 2019, [Известия высших учебных заведений. Ядерная энергетика, Izvestiya vysshikh uchebnykh zavedenii. Yadernaya energetika], P29, DOI 10.26583/npe.2019.2.03
  • [2] A summary of sodium-cooled fast reactor development
    Aoto, Kazumi
    Dufour, Philippe
    Yang Hongyi
    Glatz, Jean Paul
    Kim, Yeong-il
    Ashurko, Yury
    Hill, Robert
    Uto, Nariaki
    [J]. PROGRESS IN NUCLEAR ENERGY, 2014, 77 : 247 - 265
  • [3] Review of in-service inspection and repair technique developments for French liquid metal fast reactors
    Baque, F
    [J]. NUCLEAR TECHNOLOGY, 2005, 150 (01) : 67 - 78
  • [4] Transparent boundary conditions for the harmonic diffraction problem in an elastic waveguide
    Baronian, V.
    Bonnet-Ben Dhia, A. S.
    Luneville, E.
    [J]. JOURNAL OF COMPUTATIONAL AND APPLIED MATHEMATICS, 2010, 234 (06) : 1945 - 1952
  • [5] ULTRASONIC VIEWING IN FAST-REACTORS
    BARRETT, LM
    MCKNIGHT, JA
    FOTHERGILL, JR
    [J]. PHYSICS IN TECHNOLOGY, 1984, 15 (06): : 308 - 314
  • [6] COMSOL AB Stockholm Sweden, 2019, COMSOL MULT V 5 4
  • [7] MODE CONVERSION OF RAYLEIGH AND LAMB WAVES TO COMPRESSION WAVES AT A METAL-LIQUID INTERFACE
    DEIGHTON, MO
    GILLESPIE, AB
    PIKE, RB
    WATKINS, RD
    [J]. ULTRASONICS, 1981, 19 (06) : 249 - 258
  • [8] Griffin J.W., 2009, Under-Sodium viewing: a review of ultrasonic imaging technology for liquid metal fast reactors
  • [9] Development of ultrasonic waveguide sensor for under-sodium inspection in a sodium-cooled fast reactor
    Joo, Young-Sang
    Park, Chang-Gyu
    Lee, Jae-Han
    Kim, Jong-Bum
    Lim, Sa-Hoe
    [J]. NDT & E INTERNATIONAL, 2011, 44 (02) : 239 - 246
  • [10] Karasawa H, 2000, J NUCL SCI TECHNOL, V37, P769, DOI [10.3327/jnst.37.769, 10.1080/18811248.2000.9714955]