Comparison of different focusing fiber tips for improved oral diode laser surgery

被引:23
作者
Stock, Karl [1 ]
Stegmayer, Thomas [1 ]
Graser, Rainer [1 ]
Foerster, Wolfram [1 ]
Hibst, Raimund [1 ]
机构
[1] Univ Ulm, Inst Lasertechnol Med & Messtech, D-89081 Ulm, Germany
关键词
diode laser; dentistry; oral surgery; fiber tips; soft tissue; cutting efficacy; 980; NM; SOFT-TISSUE;
D O I
10.1002/lsm.22091
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background and Objectives State of the art for use of the fiber guided diode laser in dental therapy is the application of bare fibers. A novel concept with delivery fiber and exchangeable fiber tips enables the use of tips with special and optimized geometries for various applications. The aim of this study is the comparison of different focusing fiber tips for enhanced cutting efficacy in oral surgery. Material and Methods For this purpose various designs of tip geometry were investigated and optimized by ray tracing simulations. Two applicators, one with a sphere, and another one with a taper, were realized and tested on porcine gingiva (diode laser, 940?nm, 5?W/cw; 7?W/modulated). The cutting depth and quality were determined by light microscope. Histological sections of the cuts were prepared by a cryo-microtome and microscopically analyzed to determine the cut depths and thermal damage zones. Results The simulations show that, using a sphere as fiber tip, an intensity increase of up to a factor of 16.2 in air, and 13.2 in water compared to a bare 200?mu m fiber can be achieved. Although offering high focusing factor in water, the cutting quality of the sphere was rather poor. This is probably caused by a derogation of the focusing quality due to contamination during cutting and light scattering. Much better results were achieved with conically shaped fiber tips. Compared to bare fibers they exhibit improved handling properties with no hooking, more regular and deeper cuts (5?W/cw: 2,393?+/-?468?mu m, compared to the cleaved bare fiber 5?W/cw: 711?+/-?268?mu m). The thermal damage zones of the cuts are comparable for the various tips and fibers. Conclusions In conclusion the results of our study show that cutting quality and efficiency of diode laser on soft tissue can be significantly improved using conically shaped fiber tips. Lasers Surg. Med. 44: 815823, 2012. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:815 / 823
页数:9
相关论文
共 17 条
  • [1] Avwioro G., 2011, Journal of Pharmacy and Clinical Sciences, V1, P24
  • [2] Reduction of collateral thermal impact of diode laser irradiation on soft tissue due to modified application parameters
    Beer, F.
    Koerpert, W.
    Passow, H.
    Steidler, A.
    Meinl, A.
    Buchmair, A. G.
    Moritz, A.
    [J]. LASERS IN MEDICAL SCIENCE, 2012, 27 (05) : 917 - 921
  • [3] Diode laser (980 nm) as adjunct to scaling and root planing
    Borrajo, JLL
    Varela, LG
    Castro, GL
    Rodríguez-Nuñez, I
    Torreira, MG
    [J]. PHOTOMEDICINE AND LASER SURGERY, 2004, 22 (06) : 509 - 512
  • [4] Capodiferro S, 2008, Minerva Stomatol, V57, P1
  • [5] Capodiferro S, 2008, MINERVA STOMATOL, V57, P6
  • [6] Caruso U, 2008, NEW MICROBIOL, V31, P513
  • [7] Lasers in dentistry - Separating science from hype
    Dederick, DN
    Bushick, RD
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2004, 135 (02) : 204 - 212
  • [8] Desiate A, 2009, INT J MED SCI, V6, P358
  • [9] Goharkhay K, 1999, LASER SURG MED, V25, P401, DOI 10.1002/(SICI)1096-9101(1999)25:5<401::AID-LSM6>3.0.CO
  • [10] 2-U