Separability of Multiple Deep Crack Defects With an NDE Eddy Current System

被引:7
作者
Hamia, R. [1 ]
Cordier, C.
Dolabdjian, C.
机构
[1] Univ Caen Basse Normandie, GREYC UMR 6072, F-14050 Caen, France
关键词
Eddy current testing (ECT); magnetometer; multiple cracks and spatial resolution; nondestructive testing (NDT); MAGNETOMETER;
D O I
10.1109/TMAG.2012.2218796
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Finite element simulation was carried out to characterize the separability of an eddy current nondestructive testing (EC-NDT) system in the case of the detection of deep cracks located in an aluminum plate. The interaction among multiple cracks was also analyzed. The results show that the separability of the EC system not only depends on the sensitive element dimensions but also on different parameters of the system, such as the sensor lift-off, the excitation frequency and the cracks depth. Furthermore, the simulations show that under some conditions, the magnetic response sensed for multiple cracks can be calculated as the superposition of the signals obtained for each crack. This point essentially simplifies the solution of the inverse problem of crack reconstruction.
引用
收藏
页码:124 / 127
页数:4
相关论文
共 10 条
[1]   GMR-Based ECT Instrument for Detection and Characterization of Crack on a Planar Specimen: A Hand-Held Solution [J].
Betta, Giovanni ;
Ferrigno, Luigi ;
Laracca, Marco .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2012, 61 (02) :505-512
[2]   Improvement in the detection of subsurface fatigue cracks under airframe fasteners using improved rotating giant magneto-resistance magnetometer head [J].
Dolabdjian, C. ;
Wache, G. ;
Perez, L. .
INSIGHT, 2007, 49 (03) :133-136
[3]   Detection of flaws in ferromagnetic samples based on low frequency eddy current imaging [J].
Fujita, Y ;
Sasada, I .
JOURNAL OF APPLIED PHYSICS, 2003, 93 (10) :8277-8279
[4]   Giant Magnetoimpedance Sensor for Non Destructive Evaluation Eddy Current System [J].
Hamia, R. ;
Cordier, C. ;
Saez, S. ;
Dolabdjian, C. .
SENSOR LETTERS, 2009, 7 (03) :437-441
[5]   Eddy-Current Nondestructive Testing Using an Improved GMR Magnetometer and a Single Wire as Inducer: A FEM Performance Analysis [J].
Hamia, Rimond ;
Cordier, Christophe ;
Saez, Sebastien ;
Dolabdjian, Christophe .
IEEE TRANSACTIONS ON MAGNETICS, 2010, 46 (10) :3731-3737
[6]  
Perez L, 2004, J ELECT ENG, V55, P10
[7]  
PEREZ L, 2004, 16 WCNDT 04 C MONTR
[8]   Analytical Model for the Extraction of Flaw-Induced Current Interactions for SQUID NDE [J].
Sarreshtedari, Farrokh ;
Hosseini, Mehdi ;
Razmkhah, Sasan ;
Mehrany, Khashayar ;
Kokabi, Hamid ;
Schubert, Juergen ;
Banzet, Marko ;
Krause, Hans-Joachim ;
Fardmanesh, Mehdi .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (04) :3442-3446
[9]   Pulsed magnetic flux leakage techniques for crack detection and characterisation [J].
Sophian, A ;
Tian, GY ;
Zairi, S .
SENSORS AND ACTUATORS A-PHYSICAL, 2006, 125 (02) :186-191
[10]   Eddy current nondestructive testing with giant magneto-impedance sensor [J].
Vacher, F. ;
Alves, F. ;
Gilles-Pascaud, C. .
NDT & E INTERNATIONAL, 2007, 40 (06) :439-442