Effect of microneedles shape on skin penetration and minimally invasive continuous glucose monitoring in vivo

被引:87
作者
Chua, Beelee [1 ]
Desai, Shashi P. [1 ]
Tierney, Michael J. [1 ]
Tamada, Janet A. [1 ]
Jina, Arvind N. [1 ]
机构
[1] ArKal Med Inc, Fremont, CA 94538 USA
关键词
Microneedle array; Microneedle shape; Interstitial fluid; Skin penetration; Crack propagation; Continuous glucose monitoring; ARRAY; DELIVERY; GANGRENE; SOLIDS; FORCE;
D O I
10.1016/j.sna.2013.09.026
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The effect of microneedle shape on skin penetration and minimally invasive continuous glucose monitoring (CGM) was successfully investigated. Straight silicon microneedle arrays (SSMA) and tapered silicon microneedle arrays (TSMA) were fabricated using standard silicon micromachining techniques. Microneedle heights were similar to 325 mu m and similar to 350 mu m and pitch was 400 mu m and 450 mu m, respectively. Mode-I planar crack and mode-II ring crack propagation were assumed for TSMA and SSMA penetration mechanisms, respectively. Skin penetration was first qualitatively evaluated via methylene blue staining. TSMA and SSMA were also mounted on CGM system prototypes and applied on human subjects with an impact velocity of 10 m/s and worn for 6.5 h. The hollow microneedles allowed the glucose from the interstitial fluid in the epidermis to diffuse into the sensor chamber of the CGM system prototype. Sensor currents from the applied CGM system prototypes ranged from 100 nA to 400 nA and they appeared to follow the trend of the reference blood glucose sensor that ranged from similar to 90 to 220 mg/dL. The CGM system prototype with SSMA yielded lower sensor current than that with TSMA. This may be due to the SSMA preferential penetration of skin via mode-II ring crack propagation, resulting in possible lumen occlusion from displaced skin material. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:373 / 381
页数:9
相关论文
共 45 条
[1]   Formation of polymer microneedle arrays using soft lithography [J].
Ami, Yoshimichi ;
Tachikawa, Hiroto ;
Takano, Naoki ;
Miki, Norihisa .
JOURNAL OF MICRO-NANOLITHOGRAPHY MEMS AND MOEMS, 2011, 10 (01)
[2]  
[Anonymous], DIAB REP CARD 2012
[3]   Treatment issues in type 1 diabetes [J].
Bloomgarden, ZT .
DIABETES CARE, 2002, 25 (01) :230-236
[4]  
Brauker J. H., 2006, US Patent, Patent No. [7,134,999 B2, 7134999]
[5]   Cellular and molecular basis of wound healing in diabetes [J].
Brem, Harold ;
Tomic-Canic, Marjana .
JOURNAL OF CLINICAL INVESTIGATION, 2007, 117 (05) :1219-1222
[6]  
Burmeister JJ, 1999, CLIN CHEM, V45, P1621
[7]   A high aspect ratio SU-8 fabrication technique for hollow microneedles for transdermal drug delivery and blood extraction [J].
Chaudhri, Buddhadev Paul ;
Ceyssens, Frederik ;
De Moor, Piet ;
Van Hoof, Chris ;
Puers, Robert .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2010, 20 (06)
[8]   Hollow metal microneedles for insulin delivery to diabetic rats [J].
Davis, SP ;
Martanto, W ;
Allen, MG ;
Prausnitz, MR .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (05) :909-915
[9]   Insertion of microneedles into skin: measurement and prediction of insertion force and needle fracture force [J].
Davis, SP ;
Landis, BJ ;
Adams, ZH ;
Allen, MG ;
Prausnitz, MR .
JOURNAL OF BIOMECHANICS, 2004, 37 (08) :1155-1163
[10]   Design, Optimization and Characterisation of Polymeric Microneedle Arrays Prepared by a Novel Laser-Based Micromoulding Technique [J].
Donnelly, Ryan F. ;
Majithiya, Rita ;
Singh, Thakur Raghu Raj ;
Morrow, Desmond I. J. ;
Garland, Martin J. ;
Demir, Yusuf K. ;
Migalska, Katarzyna ;
Ryan, Elizabeth ;
Gillen, David ;
Scott, Christopher J. ;
Woolfson, A. David .
PHARMACEUTICAL RESEARCH, 2011, 28 (01) :41-57