Diffusion-weighted MR imaging with single-shot echo-planar imaging in the upper abdomen: preliminary clinical experience in 61 patients

被引:141
作者
Ichikawa, T
Haradome, H
Hachiya, J
Nitatori, T
Araki, T
机构
[1] Yamanashi Med Univ, Dept Radiol, 1110 Shimokato, Yamanashi 40938, Japan
[2] Kyorin Univ, Sch Med, Dept Radiol, Tokyo 181, Japan
来源
ABDOMINAL IMAGING | 1999年 / 24卷 / 05期
关键词
abdomen; magnetic resonance; liver; rapid imaging; diffusion study; echo planar;
D O I
10.1007/s002619900539
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: To determine the potential ability of diffusion-weighted magnetic resonance (MR) imaging with single-shot echo-planar imaging (DW imaging) in the upper abdomen by apparent diffusion coefficient (ADC) and signal:intensity ratio (SIR) measurements. Methods: DW imaging was performed in 61 clinical patients. ADCs in the liver, pancreas, spleen, kidney, and different pathological conditions were calculated. Spleen-to-liver SIR and segmental intensity difference of the liver (SID) were also calculated. Results: The mean ADCs (mm(2)/s) were 2.28 x 10(-3) +/- 0.07 in the liver, 1.44 x 10(-3) +/- 0.05 in the spleen, 1.94 x 10(-3) +/- 0.19 in the pancreas, and 5.76 x 10(-3) +/- 0.06 in the kidney. The mean ADC of cirrhotic liver was 1.96 x 10(-3) +/- 0.62, which was lower than that of normal liver. Other pathologic conditions also showed ADCs different from those of normal tissues. All DW images showed significantly higher spleen-to-liver SIRs and SIDs than did T2-weighted images (p < 0.05). Conclusion: The mean ADCs obtained with DW imaging were different in each upper abdominal organ and with each pathologic condition. DW images showed: better soft tissue contrast than did T2-weighted images with regard to SIR and CNR in depicting and characterizing upper abdominal disorders.
引用
收藏
页码:456 / 461
页数:6
相关论文
共 18 条
[1]   REAL-TIME MOVIE IMAGING FROM A SINGLE CARDIAC CYCLE BY NMR [J].
CHAPMAN, B ;
TURNER, R ;
ORDIDGE, RJ ;
DOYLE, M ;
CAWLEY, M ;
COXON, R ;
GLOVER, P ;
MANSFIELD, P .
MAGNETIC RESONANCE IN MEDICINE, 1987, 5 (03) :246-254
[2]   IN-VIVO MEASUREMENT OF WATER DIFFUSION IN THE HUMAN HEART [J].
EDELMAN, RR ;
GAA, JC ;
WEDEEN, VJ ;
LOH, E ;
HARE, JM ;
PRASAD, P ;
LI, W .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) :423-428
[3]   IMPROVEMENTS IN SNAP-SHOT NUCLEAR MAGNETIC-RESONANCE IMAGING [J].
HOWSEMAN, AM ;
STEHLING, MK ;
CHAPMAN, B ;
COXON, R ;
TURNER, R ;
ORDIDGE, RJ ;
CAWLEY, MG ;
GLOVER, P ;
MANSFIELD, P ;
COUPLAND, RE .
BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (729) :822-828
[4]   SEGMENTAL INTENSITY DIFFERENCES IN THE LIVER ON MR IMAGES - A SIGN OF INTRAHEPATIC PORTAL FLOW STOPPAGE [J].
ITAI, Y ;
OHTOMO, K ;
KOKUBO, T ;
OKADA, Y ;
YAMAUCHI, T ;
YOSHIDA, H .
RADIOLOGY, 1988, 167 (01) :17-19
[5]  
Le Bihan D, 1991, Magn Reson Q, V7, P1
[6]   IMAGING OF DIFFUSION AND MICROCIRCULATION WITH GRADIENT SENSITIZATION - DESIGN, STRATEGY, AND SIGNIFICANCE [J].
LEBIHAN, D ;
TURNER, R ;
MOONEN, CTW ;
PEKAR, J .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (01) :7-28
[7]   DIFFUSION-WEIGHTED MR IMAGING OF ANISOTROPIC WATER DIFFUSION IN CAT CENTRAL-NERVOUS-SYSTEM [J].
MOSELEY, ME ;
COHEN, Y ;
KUCHARCZYK, J ;
MINTOROVITCH, J ;
ASGARI, HS ;
WENDLAND, MF ;
TSURUDA, J ;
NORMAN, D .
RADIOLOGY, 1990, 176 (02) :439-445
[8]  
MOSELEY ME, 1990, AM J NEURORADIOL, V11, P423
[9]  
MULLER MF, 1994, RADIOLOGY, V190, P475
[10]  