DREAM - a novel approach for robust, ultrafast, multislice B1 mapping

被引:242
作者
Nehrke, Kay [1 ]
Boernert, Peter [1 ]
机构
[1] Philips Res Labs, Hamburg, Germany
关键词
B1; mapping; radiofrequency shimming; high-field MRI; parallel transmission; BLOCH-SIEGERT SHIFT; RADIOFREQUENCY FIELD; IN-VIVO; PHASED-ARRAY; MRI; EXCITATION; COIL; CALIBRATION;
D O I
10.1002/mrm.24158
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A novel multislice B1-mapping method dubbed dual refocusing echo acquisition mode is proposed, able to cover the whole transmit coil volume in only one second, which is more than an order of magnitude faster than established approaches. The dual refocusing echo acquisition mode technique employs a stimulated echo acquisition mode (STEAM) preparation sequence followed by a tailored single-shot gradient echo sequence, measuring simultaneously the stimulated echo and the free induction decay as gradient-recalled echoes, and determining the actual flip angle of the STEAM preparation radiofrequency pulses from the ratio of the two measured signals. Due to an elaborated timing scheme, the method is insensitive against susceptibility/chemical shift effects and can deliver a B0 phase map and a transceive phase map for free. The approach has only a weak T1 and T2 dependence and moreover, causes only a low specific absorption rate (SAR) burden. The accuracy of the method with respect to systematic and statistical errors is investigated both, theoretically and in experiments on phantoms. In addition, the performance of the approach is demonstrated in vivo in B1-mapping and radiofrequency shimming experiments on the abdomen, the legs, and the head on an eight-channel parallel transmit 3 T MRI system. Magn Reson Med, 2012. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:1517 / 1526
页数:10
相关论文
共 38 条
[1]   RADIOFREQUENCY MAP OF AN NMR COIL BY IMAGING [J].
AKOKA, S ;
FRANCONI, F ;
SEGUIN, F ;
LEPAPE, A .
MAGNETIC RESONANCE IMAGING, 1993, 11 (03) :437-441
[2]   RAPID RADIOFREQUENCY CALIBRATION IN MRI [J].
CARLSON, JW ;
KRAMER, DM .
MAGNETIC RESONANCE IN MEDICINE, 1990, 15 (03) :438-445
[3]   Rapid B1+ Mapping Using a Preconditioning RF Pulse with TurboFLASH Readout [J].
Chung, Sohae ;
Kim, Daniel ;
Breton, Elodie ;
Axel, Leon .
MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (02) :439-446
[4]   Saturated double-angle method for rapid B1 plus mapping [J].
Cunningham, Charles H. ;
Pauly, John M. ;
Nayak, Krishna S. .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (06) :1326-1333
[5]   Trabecular bone volume fraction mapping by low-resolution MRI [J].
Fernández-Seara, MA ;
Song, HK ;
Wehrli, FW .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (01) :103-113
[6]   RAPID NMR IMAGING USING STIMULATED ECHOES [J].
FRAHM, J ;
HAASE, A ;
MATTHAEI, D ;
MERBOLDT, KD ;
HANICKE, W .
JOURNAL OF MAGNETIC RESONANCE, 1985, 65 (01) :130-135
[7]   STIMULATED ECHO IMAGING [J].
FRAHM, J ;
MERBOLDT, KD ;
HANICKE, W ;
HAASE, A .
JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (01) :81-93
[8]  
Graesslin I, 2006, P INT SOC MAG RESON, V14
[9]   SNAPSHOT FLASH MRI - APPLICATIONS TO T1, T2, AND CHEMICAL-SHIFT IMAGING [J].
HAASE, A .
MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (01) :77-89
[10]   Rapid radiofrequency field mapping in vivo using single-shot STEAM MRI [J].
Helms, Gunther ;
Finsterbusch, Jurgen ;
Weiskopf, Nikolaus ;
Dechent, Peter .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (03) :739-743