Nano-rheology of hydrogels using direct drive force modulation atomic force microscopy

被引:72
|
作者
Nalam, Prathima C. [1 ]
Gosvami, Nitya N. [1 ]
Caporizzo, Matthew A. [2 ]
Composto, Russell J. [2 ]
Carpick, Robert W. [1 ,2 ]
机构
[1] Univ Penn, Dept Mech Engn & Appl Mech, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Mat Sci & Engn, Philadelphia, PA 19104 USA
基金
瑞士国家科学基金会; 美国国家科学基金会;
关键词
MECHANICAL-PROPERTIES; EXTRACELLULAR-MATRIX; POLYMER GELS; CELLS; VISCOELASTICITY; MICRORHEOLOGY; CARTILAGE; TISSUE; ELASTICITY; ADHESION;
D O I
10.1039/c5sm01143d
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
We present a magnetic force-based direct drive modulation method to measure local nano-rheological properties of soft materials across a broad frequency range (10 Hz to 2 kHz) using colloid-attached atomic force microscope (AFM) probes in liquid. The direct drive method enables artefact-free measurements over several decades of excitation frequency, and avoids the need to evaluate medium-induced hydrodynamic drag effects. The method was applied to measure the local mechanical properties of polyacrylamide hydrogels. The frequency-dependent storage stiffness, loss stiffness, and loss tangent (tan d) were quantified for hydrogels having high and low crosslinking densities by measuring the amplitude and the phase response of the cantilever while the colloid was in contact with the hydrogel. The frequency bandwidth was further expanded to lower effective frequencies (0.1 Hz to 10 Hz) by obtaining force-displacement (FD) curves. Slow FD measurements showed a recoverable but highly hysteretic response, with the contact mechanical behaviour dependent on the loading direction: approach curves showed Hertzian behaviour while retraction curves fit the JKR contact mechanics model well into the adhesive regime, after which multiple detachment instabilities occurred. Using small amplitude dynamic modulation to explore faster rates, the load dependence of the storage stiffness transitioned from Hertzian to a dynamic punch-type (constant contact area) model, indicating significant influence of material dissipation coupled with adhesion. Using the appropriate contact model across the full frequency range measured, the storage moduli were found to remain nearly constant until an increase began near similar to 100 Hz. The softer gels' storage modulus increased from 7.9 +/- 0.4 to 14.5 +/- 2.1 kPa (similar to 85%), and the stiffer gels' storage modulus increased from 16.3 +/- 1.1 to 31.7 +/- 5.0 kPa (similar to 95%). This increase at high frequencies may be attributed to a contribution from solvent confinement in the hydrogel (poroelasticity). The storage moduli measured by both macrorheometry and AFM FD curves were comparable to those measured using the modulation method at their overlapping frequencies (10-25 Hz). In all cases, care was taken to ensure the contact mechanics models were applied within the important limit of small relative deformations. This study thus highlights possible transitions in the probe-material contact mechanical behaviour for soft matter, especially when the applied strain rates and the material relaxation rates become comparable. In particular, at low frequencies, the modulus follows Hertzian contact mechanics, while at high frequencies adhesive contact is well represented by punch-like behaviour. More generally, use of the Hertz model on hydrogels at high loading rates, at high strains, or during the retraction portion of FD curves, leads to significant errors in the calculated moduli.
引用
收藏
页码:8165 / 8178
页数:14
相关论文
共 50 条
  • [21] Micromechanical property analyses of decellularized vessels by atomic force microscopy
    Peng, Xiaobo
    Kristi, Natalia
    Gafur, Alidha
    Wang, Jintao
    Wang, Guixue
    Ye, Zhiyi
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2019, 52 (42)
  • [22] Nano tribological characterization of human hair and skin using atomic force microscopy
    LaTorre, C
    Bhushan, B
    ULTRAMICROSCOPY, 2005, 105 (1-4) : 155 - 175
  • [23] Mechanically tunable multiphoton fabricated protein hydrogels investigated using atomic force microscopy
    Khripin, Constantine Y.
    Brinker, C. Jeffrey
    Kaehr, Bryan
    SOFT MATTER, 2010, 6 (12) : 2842 - 2848
  • [24] High Acyl Galan Networks Probed by Rheology and Atomic Force Microscopy
    Ikeda, Shinya
    Gohtani, Shoichi
    Nishinari, Katsuyoshi
    Zhong, Qixin
    FOOD SCIENCE AND TECHNOLOGY RESEARCH, 2013, 19 (02) : 201 - 210
  • [25] Elastic properties of hydrogels and decellularized tissue sections used in mechanobiology studies probed by atomic force microscopy
    Gimenez, Alicia
    Jose Uriarte, Juan
    Vieyra, Joan
    Navajas, Daniel
    Alcaraz, Jordi
    MICROSCOPY RESEARCH AND TECHNIQUE, 2017, 80 (01) : 85 - 96
  • [26] Atomic force microscopy force-distance curves with small amplitude ultrasonic modulation
    Ma, Chengfu
    Chen, Yuhang
    Wang, Tian
    Chu, Jiaru
    SCANNING, 2015, 37 (04) : 284 - 293
  • [27] Direct force measurements between carboxylate-modified latex microspheres and glass using atomic force microscopy
    Assemi, Shoeleh
    Nalaskowski, Jakub
    Johnson, William Paul
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2006, 286 (1-3) : 70 - 77
  • [28] High resolution imaging of soft alginate hydrogels by atomic force microscopy
    Solbu, Anita Akbarzadeh
    Koernig, Andre
    Kjesbu, Joachim S.
    Zaytseva-Zotova, Daria
    Sletmoen, Marit
    Strand, Berit L.
    CARBOHYDRATE POLYMERS, 2022, 276
  • [29] Measuring the Stiffness of Ex Vivo Mouse Aortas Using Atomic Force Microscopy
    Bae, Yong Ho
    Liu, Shu-lin
    Byfield, Fitzroy J.
    Janmey, Paul A.
    Assoian, Richard K.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2016, (116):
  • [30] Atomic force microscopy-based force spectroscopy u biological and biomedical applications
    Carvalho, Filomena A.
    Santos, Nuno C.
    IUBMB LIFE, 2012, 64 (06) : 465 - 472