Combined application of single-energy metal artifact reduction and reconstruction techniques in patients with Cochlear implants

被引:8
作者
Wei, Fanqin [1 ,2 ,3 ]
Li, Jiahui [1 ,2 ,3 ,4 ]
Zhou, Chunxiang [1 ,2 ,3 ]
Li, Yun [1 ,2 ,3 ]
Wang, Xianren [1 ,2 ,3 ]
Huang, Bixue [1 ,2 ,3 ]
Sun, Qiyang [1 ,2 ,3 ]
Xiong, Guanxia [1 ,2 ,3 ]
机构
[1] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Otorhinolaryngol Head & Neck Surg, 2nd Zhongshan Rd 58, Guangzhou 510080, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Inst Otorhinolaryngol Head & Neck Surg, Guangzhou 510080, Guangdong, Peoples R China
[3] Guangzhou Key Lab Otorhinolaryngol, Guangzhou 510080, Guangdong, Peoples R China
[4] Guangzhou Women & Childrens Med Ctr, Guangzhou 510623, Guangdong, Peoples R China
关键词
SEMAR; electrode; Image quality; Computed tomography; ELECTRODE ARRAY; TEMPORAL BONE; COMPUTED-TOMOGRAPHY; IMAGE QUALITY; CT; SURGERY; LOCALIZATION; INSERTION; POSITION; HIP;
D O I
10.1186/s40463-020-00462-1
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Background The purpose of this study was to develop an effective method of reducing metal artifacts in cochlear implant (CI) electrodes. Methods The temporal bones of 30 patients (34 ears) after CI were examined with 320-detector row computed tomography, which was evaluated by two senior radiologists using a double-blind method. Noise, artifact index, signal-to-noise ratio, and the subjective image quality score were compared before versus after using single-energy metal artifact reduction (SEMAR). The electrode position, single electrode visibility, and electrode count were evaluated using SEMAR combined with either multi-planar reconstruction (MPR) or maximum intensity projection. Results The two radiologists' measurements had good consistency. SEMAR significantly reduced the image noise and artifacts index and significantly improved the signal-to-noise ratio and subjective image quality score (P < 0.01). The combination of SEMAR with MPR was conducive to accurate assessment of electrode position and single-electrode visibility. The combination of SEMAR with MIP facilitated accurate and intuitive matching of the assessed electrode count with the number of electrodes implanted during the operation (P = 0.062). Conclusion SEMAR significantly reduces metal artifacts generated by CI electrodes and improves the quality of computed tomography images. The combination of SEMAR with MPR and maximum intensity projection is beneficial for evaluating the position and number of CI electrodes.
引用
收藏
页数:9
相关论文
共 24 条
  • [1] Quality control after insertion of the nucleus contour and contour advance electrode in adults
    Aschendorff, Antje
    Kromeier, Jan
    Klenzner, Thomas
    Laszig, Roland
    [J]. EAR AND HEARING, 2007, 28 (02) : 75S - 79S
  • [2] Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation
    Bamberg, Fabian
    Dierks, Alexander
    Nikolaou, Konstantin
    Reiser, Maximilian F.
    Becker, Christoph R.
    Johnson, Thorsten R. C.
    [J]. EUROPEAN RADIOLOGY, 2011, 21 (07) : 1424 - 1429
  • [3] Flat-panel volume computed tomography for cochlear implant electrode array examination in isolated temporal bone specimens
    Bartling, Soenke H.
    Gupta, Rajiv
    Torkos, Attila
    Dullin, Christian
    Eckhardt, Grabbe
    Lenarz, Thomas
    Becker, Hartmut
    Stöver, Timo
    [J]. OTOLOGY & NEUROTOLOGY, 2006, 27 (04) : 491 - 498
  • [4] Image Fusion in Dual Energy Computed Tomography Effect on Contrast Enhancement, Signal-to-Noise Ratio and Image Quality in Computed Tomography Angiography
    Behrendt, Florian F.
    Schmidt, Bernhard
    Plumhans, Cedric
    Keil, Sebastian
    Woodruff, Seth G.
    Ackermann, Diana
    Muehlenbruch, Georg
    Flohr, Thomas
    Guenther, Rolf W.
    Mahnken, Andreas H.
    [J]. INVESTIGATIVE RADIOLOGY, 2009, 44 (01) : 1 - 6
  • [5] Electrode insertion depth in cochlear implantees estimated during surgery, on plain film radiographs and with electrode function testing
    Bettman, RHR
    van Olphen, AF
    Zonneveld, FW
    Huizing, EH
    [J]. EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2003, 260 (10) : 536 - 540
  • [6] CT and MRI of hip arthroplasty
    Cahir, J. G.
    Toms, A. P.
    Marshall, T. J.
    Wimhurst, J.
    Nolan, J.
    [J]. CLINICAL RADIOLOGY, 2007, 62 (12) : 1163 - 1171
  • [7] Revision cochlear implant surgery: Causes and outcome
    Fayad, JN
    Baino, T
    Parisier, SC
    [J]. OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2004, 131 (04) : 429 - 432
  • [8] Role of Electrode Placement as a Contributor to Variability in Cochlear Implant Outcomes
    Finley, Charles C.
    Holden, Timothy A.
    Holden, Laura K.
    Whiting, Bruce R.
    Chole, Richard A.
    Neely, Gail J.
    Hullar, Timothy E.
    Skinner, Margaret W.
    [J]. OTOLOGY & NEUROTOLOGY, 2008, 29 (07) : 920 - 928
  • [9] CT-maximum intensity projection is a clinically useful modality for the detection of gastric varices
    Ishikawa, Toru
    Ushiki, Takashi
    Mizuno, Ken-ichi
    Togashi, Tadayuki
    Watanabe, Kouji
    Seki, Kei-ichi
    Ohta, Hironobu
    Yoshida, Toshiaki
    Takeda, Keiko
    Kamimura, Tomoteru
    [J]. WORLD JOURNAL OF GASTROENTEROLOGY, 2005, 11 (47) : 7515 - 7519
  • [10] CT of the normal temporal bone:: Comparison of multiand single-detector row CT
    Jäger, L
    Bonell, H
    Liebl, M
    Srivastav, S
    Arbusow, V
    Hempel, M
    Reiser, M
    [J]. RADIOLOGY, 2005, 235 (01) : 133 - 141