An Integrated Optoacoustic Transducer Combining Etalon And Black PDMS Structures

被引:36
作者
Hou, Yang [1 ,2 ]
Ashkenazi, Sahi [1 ,2 ]
Huang, Sheng-Wen [1 ,2 ]
O'Donnell, Matthew [3 ]
机构
[1] Univ Michigan, Dept Elect Engn & Comp Sci, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[3] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
关键词
D O I
10.1109/TUFFC.2008.988
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
An integrated optoacoustic transducer combining etalon and black polydimethylsiloxane (PDMS) structures has been designed and developed. The device consists of in 11-mu m-thick black PDMS film confined to a 2-mm-diameter circular region acting as an optoacoustic transmitter, surrounded by a 5.9-mu m Fabry-Perot polymer etalon structure serving as an optoacoustic detector array. A pulsed laser is focused onto a 30-mu m spot on the black PDMS film, defining the transmit element, while a CW laser probes it 20-mu m spot on the etalon for ultrasound detection. Pulse-echo signals display center frequencies of above 30 MHz with bandwidths of at least 40 MHz. A theta-array is formed for 3-D ultrasound imaging by mechanically scanning the generation laser along a 1-D array and the detection laser around an annular array. Preliminary images with 3 metal wires as imaging targets are presented. Characterization of the device's acoustical properties, as well as preliminary imaging results, suggest that all-optical ultrasound transducers are potential alternatives to piezoelectric techniques for high-frequency 2-D arrays enabling 3-D high-resolution ultrasound imaging.
引用
收藏
页码:2719 / 2725
页数:7
相关论文
共 32 条
[21]   Synthetic aperture imaging with arrays of arbitrary shape - Part I: General case [J].
Norton, SJ .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (04) :399-403
[22]   A PROPOSED ANNULAR ARRAY IMAGING-SYSTEM FOR CONTACT B-SCAN APPLICATIONS [J].
ODONNELL, M .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1982, 29 (06) :331-338
[23]   Capacitive micromachined ultrasonic transducers:: Next-generation arrays for acoustic imaging? [J].
Oralkan, Ö ;
Ergun, AS ;
Johnson, JA ;
Karaman, M ;
Demirci, U ;
Kaviani, K ;
Lee, TH ;
Khuri-Yakub, BT .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (11) :1596-1610
[24]  
ORALKAN O, P 2004 IEEE ULTR S, P339
[25]   A 100-MHz ultrasound imaging system for dermatologic and ophthalmologic diagnostics [J].
Passmann, C ;
Ermert, H .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1996, 43 (04) :545-552
[26]   40-100-MHZ B-SCAN ULTRASOUND BACKSCATTER MICROSCOPE FOR SKIN IMAGING [J].
TURNBULL, DH ;
STARKOSKI, BG ;
HARASIEWICZ, KA ;
SEMPLE, JL ;
FROM, L ;
GUPTA, AK ;
SAUDER, DN ;
FOSTER, FS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (01) :79-88
[27]   Beam steering with segmented annular arrays [J].
Ullate, Luis G. ;
Godoy, Gregorio ;
Martinez, Oscar ;
Sanchez, Teresa .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (10) :1944-1954
[28]   Notes on synthetic phased-array with 2-D sparse arrays [J].
Wang, Y ;
O'Donnell, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2003, 50 (01) :103-105
[29]   Vascular imaging before, during, and after endovascular repair [J].
White, RA ;
Donayre, CE ;
Kopchok, GE ;
Walot, I ;
Mehinger, CM ;
Wilson, EP ;
deVirgilio, C .
WORLD JOURNAL OF SURGERY, 1996, 20 (06) :622-629
[30]   Optical generation of high frequency ultrasound using two-dimensional gold nanostructure [J].
Yang Hou ;
Kim, Jin-Sung ;
Ashkenazi, Shai ;
O'Donnell, Matthew ;
Guo, L. Jay .
APPLIED PHYSICS LETTERS, 2006, 89 (09)