An Integrated Optoacoustic Transducer Combining Etalon And Black PDMS Structures

被引:36
作者
Hou, Yang [1 ,2 ]
Ashkenazi, Sahi [1 ,2 ]
Huang, Sheng-Wen [1 ,2 ]
O'Donnell, Matthew [3 ]
机构
[1] Univ Michigan, Dept Elect Engn & Comp Sci, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[3] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
关键词
D O I
10.1109/TUFFC.2008.988
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
An integrated optoacoustic transducer combining etalon and black polydimethylsiloxane (PDMS) structures has been designed and developed. The device consists of in 11-mu m-thick black PDMS film confined to a 2-mm-diameter circular region acting as an optoacoustic transmitter, surrounded by a 5.9-mu m Fabry-Perot polymer etalon structure serving as an optoacoustic detector array. A pulsed laser is focused onto a 30-mu m spot on the black PDMS film, defining the transmit element, while a CW laser probes it 20-mu m spot on the etalon for ultrasound detection. Pulse-echo signals display center frequencies of above 30 MHz with bandwidths of at least 40 MHz. A theta-array is formed for 3-D ultrasound imaging by mechanically scanning the generation laser along a 1-D array and the detection laser around an annular array. Preliminary images with 3 metal wires as imaging targets are presented. Characterization of the device's acoustical properties, as well as preliminary imaging results, suggest that all-optical ultrasound transducers are potential alternatives to piezoelectric techniques for high-frequency 2-D arrays enabling 3-D high-resolution ultrasound imaging.
引用
收藏
页码:2719 / 2725
页数:7
相关论文
共 32 条
[1]   Optoacoustic imaging using thin polymer etalon [J].
Ashkenazi, S ;
Hou, Y ;
Buma, T ;
O'Donnell, M .
APPLIED PHYSICS LETTERS, 2005, 86 (13) :1-3
[2]   Two-dimensional ultrasound receive army using an angle-tuned Fabry-Perot polymer film sensor for transducer field characterization and transmission ultrasound imaging [J].
Beard, PC .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (06) :1002-1012
[3]   Transduction mechanisms of the Fabry-Perot polymer film sensing concept for wideband ultrasound detection [J].
Beard, PC ;
Pérennès, F ;
Mills, TN .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (06) :1575-1582
[4]   High-frequency ultrasound array element using thermoelastic expansion in an elastomeric film [J].
Buma, T ;
Spisar, M ;
O'Donnell, M .
APPLIED PHYSICS LETTERS, 2001, 79 (04) :548-550
[5]   Development of a 35-MHz piezo-composite ultrasound array for medical imaging [J].
Cannata, JM ;
Williams, JA ;
Zhou, QF ;
Ritter, TA ;
Shung, KK .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (01) :224-236
[6]   High-resolution ultrasonic imaging of the posterior segment [J].
Coleman, DJ ;
Silverman, RH ;
Chabi, A ;
Rondeau, MJ ;
Shung, KK ;
Cannata, J ;
Lincoff, H .
OPHTHALMOLOGY, 2004, 111 (07) :1344-1351
[7]   Forward-viewing CMUT arrays for medical Imaging [J].
Demirci, U ;
Ergun, AS ;
Oralkan, Ö ;
Karaman, M ;
Khuri-Yakub, BT .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (07) :887-895
[8]   High-density flexible interconnect for two-dimensional ultrasound arrays [J].
Fiering, JO ;
Hultman, P ;
Lee, W ;
Light, ED ;
Smith, SW .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (03) :764-770
[9]   PRINCIPLES AND APPLICATIONS OF ULTRASOUND BACKSCATTER MICROSCOPY [J].
FOSTER, FS ;
PAVLIN, CJ ;
LOCKWOOD, GR ;
RYAN, LK ;
HARASIEWICZ, KA ;
BERUBE, L ;
RAUTH, AM .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1993, 40 (05) :608-617
[10]   A new ultrasound instrument for in vivo microimaging of mice [J].
Foster, FS ;
Zhang, MY ;
Zhou, YQ ;
Liu, G ;
Mehi, J ;
Cherin, E ;
Harasiewicz, KA ;
Starkoski, BG ;
Zan, L ;
Knapik, DA ;
Adamson, SL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (09) :1165-1172