Design and Calibration of a Large Open-Ended Coaxial Probe for the Measurement of the Dielectric Properties of Concrete

被引:57
作者
Filali, Bilal [1 ]
Boone, Francois [2 ]
Rhazi, Jamal [1 ]
Ballivy, Gerard [1 ]
机构
[1] Univ Sherbrooke, Dept Civil Engn, Sherbrooke, PQ J1K 2R1, Canada
[2] Univ Sherbrooke, Dept Elect & Comp Engn, Sherbrooke, PQ J1K 2R1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Complex permittivity; concrete heterogeneity; probe admittance; reflection coefficient; scattering parameters;
D O I
10.1109/TMTT.2008.2003520
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The subject of this paper is the design and calibration of an open-ended coaxial probe for the nondestructive measurement of the dielectric properties of concrete. Measurements are made between 100-900 MHz, frequencies which are often used in geophysics and civil engineering for ground penetrating radar inspection. The probe is calibrated using measurements on saline solutions in conjunction with three different mathematical techniques for comparative study. Measurements of mortar and concrete specimens having different water/cement ratios were made in order to observe the standard deviations due to their heterogeneous nature. Similar to the case of relatively homogeneous rock specimens (limestone and granite), the standard deviation for heterogeneous concrete samples do not exceed 5%. In addition, the effect of the concrete's porosity on its dielectric properties was clearly observed: measured permittivity between 4-4.5 at 900 MHz for porous concrete, and between 6.5-7.5 at 900 MHz for dense concrete.
引用
收藏
页码:2322 / 2328
页数:7
相关论文
共 23 条
[1]  
Annan, 2003, SENSORS SOFTWARE
[2]  
*ASTM, 1998, 474898 ASTMD
[3]  
*ASTM, 1997, 608797 ASTMD
[4]   MEASUREMENT OF RADIO-FREQUENCY PERMITTIVITY OF BIOLOGICAL TISSUES WITH AN OPEN-ENDED COAXIAL LINE .1. [J].
ATHEY, TW ;
STUCHLY, MA ;
STUCHLY, SS .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1982, 30 (01) :82-86
[5]   ANALYSIS OF AN OPEN-ENDED COAXIAL PROBE WITH LIFT-OFF FOR NONDESTRUCTIVE TESTING [J].
BAKERJARVIS, J ;
JANEZIC, MD ;
DOMICH, PD ;
GEYER, RG .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1994, 43 (05) :711-718
[6]   Analysis of a two-port flanged coaxial holder for shielding effectiveness and dielectric measurements of thin films and thin materials [J].
BakerJarvis, J ;
Janezic, MD .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1996, 38 (01) :67-70
[7]   A comparative study of four open-ended coaxial probe models for permittivity measurements of lossy dielectric biological materials at microwave frequencies [J].
Berube, D ;
Ghannouchi, FM ;
Savard, P .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1996, 44 (10) :1928-1934
[8]  
BLAKHAM DV, 1997, IEEE T INSTRUM MEAS, V46, P1093
[9]   Measuring dielectric properties of concrete by a wide coaxial probe with an open end [J].
Filali, Bilal ;
Rhazi, Jamal-Eddine ;
Ballivy, Gerard .
CANADIAN JOURNAL OF PHYSICS, 2006, 84 (05) :365-379
[10]  
KARMEL PR, 1997, INTRO ELECTROMAGNETI