Results of reconstructed and fused NDT-data measured in the laboratory and on-site at bridges

被引:42
作者
Kohl, Christoph [1 ]
Streicher, Doreen [1 ]
机构
[1] BAM Fed Inst Mat Res & Testing, D-12205 Berlin, Germany
关键词
non-destructive testing; prestressed concrete bridges; radar; ultrasonic pulse echo technique; data fusion; scanning system;
D O I
10.1016/j.cemconcomp.2006.02.005
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Non-destructive testing (NDT) of concrete structures plays an increasing role in civil engineering. This paper presents the results of measurements carried out in the laboratory at BAM and on-site at several bridges using reconstructed and fused radar and ultrasonic echo data sets. In this context different scanning systems, developed for the on-site application of NDT-methods (e.g. reinforced concrete bridges) are introduced. The main object was the demonstration of the improved effectiveness of radar and ultrasonic pulse echo technique due to the automated measurements and the application of new software for the data processing and data visualisation. The results of these measurements show the high potential of reconstruction and data fusion for the improvement and simplification of the interpretability of large data sets measured with impulse-echo methods. (C) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:402 / 413
页数:12
相关论文
共 21 条
[1]  
AFSHARI A, 1996, STRUCT MAT TECHN NDT
[2]   Investigation of historic masonry via radar reflection and tomography [J].
Colla, C ;
Maierhofer, C .
GPR 2000: PROCEEDINGS OF THE EIGHTH INTERNATIONAL CONFERENCE ON GROUND PENETRATING RADAR, 2000, 4084 :893-898
[3]  
Daniels D. J., 2004, GROUND PENETRATING R
[4]  
HAARDT P, 2003, INT S NOND TEST CIV
[5]   Characterisation of surface cracks with Rayleigh waves: a numerical model [J].
Hevin, G ;
Abraham, O ;
Pedersen, HA ;
Campillo, M .
NDT & E INTERNATIONAL, 1998, 31 (04) :289-297
[6]  
Krause M, 1997, NDT&E INT, V30, P195, DOI 10.1016/S0963-8695(96)00056-4
[7]  
KRAUSE M, 2004, P 27 INT AC IM S 24, P129
[8]  
KRAUSE M, 1995, 6 INT C STRUCT FAULT, V1, P17
[9]  
KRAUSE M, 2003, INT S NOND TEST CIV
[10]  
KRIEGER J, 2001, 860101000B4 FE BUND