The hard X-ray response of the XIS-CCD for Astro-E: qualification of the X-ray CCD detector

被引:11
|
作者
Nishiuchi, M
Koyama, K
Awaki, H
Tsuru, T
Sakano, M
Hamaguchi, K
Murakami, H
Tsunemi, H
Hayashida, K
Kitamoto, S
Miyata, E
Dotani, T
Ozaki, M
Bautz, M
Doty, J
Kissel, S
Foster, R
Ricker, G
机构
[1] Kyoto Univ, Dept Phys, Cosm Ray Grp, Sakyo Ku, Kyoto 6068502, Japan
[2] Osaka Univ, Dept Earth & Space Sci, Osaka 5600043, Japan
[3] Inst Space & Astronaut Sci, Sagamihara, Kanagawa 229, Japan
[4] MIT, Ctr Space Res, Cambridge, MA 02139 USA
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 1999年 / 436卷 / 1-2期
关键词
X-ray; CCD; X-ray response;
D O I
10.1016/S0168-9002(99)00601-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report on the hard X-ray response of the CCD detector for the X-ray imaging spectrometer (XIS), to be launched on the next Japanese X-ray Astronomical Satellite, ASTRO-E, in February 2000. XIS is prepared by an international team, comprised of MIT (USA), ISAS, Osaka University and Kyoto University (JAPAN). We have evaluated the X-ray response of the XIS in its high-energy band (1.5-10 keV). Data from the fluorescent line emission of Al, Cl, Ti, Ni, Fe, Zn, Se were used to construct the response function of the CCD detectors. Details of the response function - including the energy-scale, linearity, energy resolution, quantum efficiency -, are given as a function of incident X-ray energy. We find that the tail component of high-energy photopeaks are produced by events with incomplete charge collection. We also conclude that the size of the charge clouds can be estimated using the shapes of the tail components. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:79 / 84
页数:6
相关论文
共 50 条
  • [1] Hard X-ray response of the XIS-CCD for ASTRO-E: qualification of the X-ray CCD detector
    Nishiuchi, M.
    Koyama, K.
    Awaki, H.
    Tsuru, T.
    Sakano, M.
    Hamaguchi, K.
    Murakami, H.
    Tsunemi, H.
    Hayashida, K.
    Kitamoto, S.
    Miyata, E.
    Dotani, T.
    Ozaki, M.
    Bautz, M.
    Doty, J.
    Kissel, S.
    Foster, R.
    Ricker, G.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999, 436 (1-2): : 79 - 84
  • [2] Calibration of the x-ray CCD camera (XIS) for the ASTRO-E in the soft x-ray band
    Katayama, H
    Shouho, M
    Kohmura, T
    Katayama, K
    Ohta, M
    Tsunemi, H
    Kitamoto, S
    Hayashida, K
    Miyata, E
    Yoshita, K
    Koyama, K
    Ricker, G
    Bautz, MW
    Foster, R
    Kissel, S
    Doty, J
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY X, 1999, 3765 : 721 - 728
  • [3] Ground calibration of X-ray CCD camera XIS onboard ASTRO-E
    Tsuru, T
    Nishiuchi, H
    Awaki, H
    Hamaguchi, K
    Koyama, K
    Tomida, H
    Sakano, M
    BROAD BAND X-RAY SPECTRA OF COSMIC SOURCES, 2000, 25 (3-4): : 885 - 888
  • [4] Soft X-ray response of the proto-type CCD camera (XIS) for Astro-E
    Hayashida, K
    Kitamoto, S
    Miyata, E
    Tsunemi, H
    Hashimotodani, K
    Katayama, K
    Kohmura, T
    Asakura, R
    Yoshita, K
    Katayama, H
    Shouho, M
    Koyoma, K
    Tsuru, TG
    Awaki, H
    Dotani, T
    Ozaki, M
    Ricker, G
    Doty, J
    Bautz, M
    Kissel, S
    Foster, R
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY IX, 1998, 3445 : 278 - 290
  • [5] Astro-E hard X-ray detector
    Kamae, T
    Ezawa, H
    Fukazawa, Y
    Hirayama, M
    Idesawa, E
    Iyomoto, N
    Kaneda, H
    Kawaguti, G
    Kokubun, M
    Kubo, H
    Kubota, A
    Matsushita, K
    Matsuzaki, K
    Matishima, K
    Mizuno, T
    Nakazawa, K
    Osone, S
    Obayashi, H
    Saito, Y
    Tamura, T
    Tanaka, M
    Tashiro, M
    Kataoka, J
    Murakami, T
    Ota, N
    Ozawa, H
    Sugizaki, M
    Takizawa, K
    Takahashi, T
    Yamaoka, K
    Yoshida, A
    Ikeda, H
    Tsukada, K
    Nomachi, M
    GAMMA-RAY AND COSMIC-RAY DETECTORS, TECHNIQUES, AND MISSIONS, 1996, 2806 : 314 - 328
  • [6] Reports of soft X-ray response of the engineering model of the CCD camera (XIS) for the ASTRO-E mission
    Katayama, K
    Kohmura, T
    Katayama, H
    Shouho, M
    Tsunemi, H
    Kitamoto, S
    Hayashida, K
    Miyata, E
    Hashimotodani, K
    Koyama, K
    Ricker, G
    Bautz, M
    Foster, R
    BROAD BAND X-RAY SPECTRA OF COSMIC SOURCES, 2000, 25 (3-4): : 881 - 884
  • [7] Quantum efficiency measurement of the X-ray CCD camera (XIS) for the ASTRO-E mission in the soft X-ray band
    Kohmura, T
    Katayama, K
    Katayama, H
    Shouho, M
    Tsunemi, H
    Kitamoto, S
    Hayashida, K
    Miyata, E
    Ohtani, M
    Ohta, M
    Yoshita, K
    Koyama, K
    Ricker, G
    Bautz, MW
    Foster, R
    Kissel, S
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY X, 1999, 3765 : 588 - 596
  • [8] The trial of new event analysis method with the X-ray CCD camera XIS for Astro-E
    Murakami, H
    Tsuru, T
    Awaki, H
    Sakano, M
    Nishiuchi, M
    Hamaguchi, K
    Koyama, K
    Tsunemi, H
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY X, 1999, 3765 : 160 - 170
  • [9] Fabrication of the ASTRO-E Hard X-ray Detector
    Nakazawa, K
    Kamae, T
    Makishima, K
    Takahashi, T
    Murakami, T
    Tashiro, M
    Fukazawa, Y
    Tamura, T
    Iyomoto, N
    Ebisawa, K
    Ezoe, Y
    Hamaya, M
    Horii, M
    Isobe, N
    Kokubun, M
    Kotoku, J
    Kubota, A
    Matsumoto, Y
    Mizuno, T
    Mizuno, Y
    Mori, K
    Onishi, T
    Ota, N
    Shinoda, S
    Sugiho, M
    Taguchi, K
    Takahasi, I
    Tanaka, M
    Tanihata, C
    Terada, Y
    Uchiyama, Y
    Watanabe, S
    Yamaoka, K
    Yonetoku, D
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY X, 1999, 3765 : 148 - 159
  • [10] Soft X-ray response of X-ray CCD camera XIS onboard Astro-E2
    Hayashida, K
    Torii, K
    Namiki, M
    Shiroshoji, T
    Shoji, M
    Katsuda, S
    Matsuura, D
    Miyauchi, T
    Tsunemi, H
    Kohmura, T
    Katayama, H
    UV AND GAMMA-RAY SPACE TELESCOPE SYSTEMS, PTS 1 AND 2, 2004, 5488 : 73 - 84