Post-mortem computed tomography compared to forensic autopsy findings: a French experience

被引:77
作者
Le Blanc-Louvry, Isabelle [1 ]
Thureau, Sophie [1 ]
Duval, Cathia [2 ]
Papin-Lefebvre, Frederique [3 ]
Thiebot, Jacques [2 ]
Dacher, Jean Nicolas [2 ]
Gricourt, Cyril [1 ]
Toure, Emmanuel [1 ]
Proust, Bernard [1 ]
机构
[1] Rouen Univ Hosp, Dept Forens Med, F-76031 Rouen, France
[2] Rouen Univ Hosp, Dept Radiol, F-76031 Rouen, France
[3] Caen Univ Hosp, Dept Forens Med, F-14000 Caen, France
关键词
Post-mortem CT; Autopsy; Cause of death; Prospective studies; Diagnostic tool; MINIMALLY INVASIVE AUTOPSY; VIRTUAL AUTOPSY; MSCT; VIRTOPSY; VICTIMS; BODY; MRI; CT;
D O I
10.1007/s00330-013-2779-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The principal aim of our study was to establish concordance between post-mortem CT (PMCT) and forensic standard autopsy (SA) in detecting lesions according to different anatomical regions. A secondary aim was to determine the efficacy of PMCT in showing lethal lesions. PMCTs were compared with autopsies in 236 cadavers in different contexts of death. PMCT findings were assessed by two independent radiologists. Concordance between PMCT and autopsy was almost perfect in showing skull, basal skull and hyoid bone fractures as well as in detecting facial, vertebral or pelvic fractures. Both examinations were discordant in demonstrating some intracranial injuries, vascular or organ wounds (more findings showed by autopsy), as well in showing free air in anatomical cavities (more findings detected by PMCT). Moreover, PMCT was effective in determining lethal lesions in the context of craniofacial trauma or after a gunshot wound. Concordance between the findings of the two radiologists was almost perfect for each type of lesion. PMCT could be considered as effective as SA in determining the cause of death in certain traumatic events. It was also effective in showing lethal lesions and could be a useful tool in reducing the number of SA. aEuro cent Post-mortem CT is increasingly performed as an alternative/adjunct to formal autopsy. aEuro cent More modern CT systems provide greater anatomical scope. aEuro cent PMCT can usually determine the cause of most deaths following trauma. aEuro cent Prospective studies are still required to establish an algorithm for forensic CT.
引用
收藏
页码:1829 / 1835
页数:7
相关论文
共 25 条
  • [1] Postmortem Imaging-Guided Biopsy as an Adjuvant to Minimally Invasive Autopsy With CT and Postmortem Angiography: A Feasibility Study
    Bolliger, Stephan A.
    Filograna, Laura
    Spendlove, Danny
    Thali, Michael J.
    Dirnhofer, Stephan
    Ross, Steffen
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (05) : 1051 - 1056
  • [2] DiMaio VJ, 2001, FORENSIC PATHOLOGY, P416
  • [3] Multi-phase post-mortem CT angiography: development of a standardized protocol
    Grabherr, Silke
    Doenz, Francesco
    Steger, Beat
    Dirnhofer, Richard
    Dominguez, Alejandro
    Sollberger, Barbara
    Gygax, Erich
    Rizzo, Elena
    Chevallier, Christine
    Meuli, Reto
    Mangin, Patrice
    [J]. INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2011, 125 (06) : 791 - 802
  • [4] Value of postmortem thoracic CT over radiography in imaging of pediatric rib fractures
    Hong, Terence S.
    Reyes, Jeanette A.
    Moineddin, Rahim
    Chiasson, David A.
    Berdon, Walter E.
    Babyn, Paul S.
    [J]. PEDIATRIC RADIOLOGY, 2011, 41 (06) : 736 - 748
  • [5] Virtopsy: postmortem imaging of the human heart in situ using MSCT and MRI
    Jackowski, C
    Schweitzer, W
    Thali, M
    Yen, K
    Aghayev, E
    Sonnenschein, M
    Vock, P
    Dirnhofer, R
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2005, 149 (01) : 11 - 23
  • [6] Jeffery AJ., 2010, DIAGN HISTOPATHOL, V16, P546, DOI [10.1016/j.mpdhp.2010.08.017, DOI 10.1016/J.MPDHP.2010.08.017]
  • [7] MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA
    LANDIS, JR
    KOCH, GG
    [J]. BIOMETRICS, 1977, 33 (01) : 159 - 174
  • [8] Virtual autopsy: Two- and three-dimensional multidetector CT findings in drowning with autopsy comparison
    Levy, Angela D.
    Harcke, H. Theodore
    Getz, John M.
    Mallak, Craig T.
    Caruso, James L.
    Pearse, Lisa
    Frazier, Aletta A.
    Galvin, Jeffrey R.
    [J]. RADIOLOGY, 2007, 243 (03) : 862 - 868
  • [9] Virtual autopsy: Preliminary experience in high-velocity gunshot wound victims
    Levy, Angela D.
    Abbott, Robert M.
    Mallak, Craig T.
    Getz, John M.
    Harcke, H. Theodore
    Champion, Howard R.
    Pearse, Lisa A.
    [J]. RADIOLOGY, 2006, 240 (02) : 522 - 528
  • [10] Postmortem Imaging MDCT Features of Postmortem Change and Decomposition
    Levy, Angela D.
    Harcke, Howard Theodore
    Mallak, Craig T.
    [J]. AMERICAN JOURNAL OF FORENSIC MEDICINE AND PATHOLOGY, 2010, 31 (01) : 12 - 17