Failure analysis of bolts on an end flange of a steam pipe

被引:7
作者
Chen, HS
Tseng, PT
Hwang, SF
机构
[1] Natl Yunlin Univ Sci & Technol, Dept Mech Engn, Touliu, Yunlin, Taiwan
[2] Natl Huwei Univ Sci & Technol, Dept Mat Sci & Engn, Tenri, Nara 632, Japan
关键词
fracture mechanics; fatigue; life prediction; bolt; pipe;
D O I
10.1016/j.engfailanal.2004.10.019
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This paper gives a case study about the failure of steam pipe fitting equipment in a chemical factory. The observation and analysis are done by way of SEM, EDS, tensile tests, and fracture mechanics. The reasons for failure, the fracture mechanisms, and the failure modes are revealed and discussed. A prediction of the fatigue life of a bolt of the fitting flange is made. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:656 / 668
页数:13
相关论文
共 4 条
[1]  
Broek D, 1986, ELEMENTARY ENG FRACT
[2]   Stress intensity factors for elliptical surface cracks in round bars with different stress concentration coefficient [J].
Guo, W ;
Shen, H ;
Li, H .
INTERNATIONAL JOURNAL OF FATIGUE, 2003, 25 (08) :733-741
[3]  
SHIH GC, 1973, HDB STRESS INTENSITY
[4]  
Tada H., 1973, STRESS ANAL CRACKS H