Analysis of lead and zinc by mercury-free potentiometric stripping analysis

被引:0
|
作者
Andersen, JET
机构
关键词
potentiometric stripping analysis; electrochemistry; trace-metal analysis;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method is presented for trace-element analysis of lead and zinc by potentiometric stripping analysis (PSA) where both the glassy-carbon working electrode and the electrolyte are free of mercury. Analysis of zinc requires an activation of the glassy-carbon electrode. The activation is performed by preconcentrating zinc on glassy carbon at -1400 mV(SCE) in a mercury-free electrolyte containing 0.1 M HCl and 2 ppm Zn2+, followed by stripping at approx. -1050 mV. A linear relationship between stripping peak areas, recorded in the derivative mode, and concentration was found in the range 0-2000 ppb.
引用
收藏
页码:1001 / 1012
页数:12
相关论文
共 50 条
  • [1] Method for blood lead determination by potentiometric stripping analysis
    Mathieu, H
    Le Moigne, F
    Panteix, G
    Derache, P
    Jouzier, E
    ANNALES DE BIOLOGIE CLINIQUE, 2003, 61 (06) : 667 - 672
  • [2] Adsorptive potentiometric stripping analysis of nucleic acids at mercury electrodes
    Wang, J
    Grant, DH
    Ozsoz, M
    Cai, XH
    Tian, BM
    Fernandes, JR
    ANALYTICA CHIMICA ACTA, 1997, 349 (1-3) : 77 - 83
  • [3] Potentiometric Stripping Analysis of Zinc, Cadmium and Lead in Tobacco Leaves (Nicotiana Tabacum L.) and Soil Samples
    Kalicanin, Biljana
    Velimirovic, Dragan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (01): : 313 - 323
  • [4] The potentiometric stripping analysis of proteins
    Honeychurch, MJ
    Ridd, MJ
    ELECTROANALYSIS, 1996, 8 (07) : 654 - 660
  • [5] Potentiometric stripping analysis of copper using cysteine modified mercury film electrode
    Bai, Y
    Ruan, XY
    Mo, JY
    Xie, YQ
    ANALYTICA CHIMICA ACTA, 1998, 373 (01) : 39 - 46
  • [6] Determination of copper, zinc, and selenium in human plasma and urine samples by potentiometric stripping analysis and constant current stripping analysis
    Gozzo, ML
    Colacicco, L
    Callà, C
    Barbaresi, G
    Parroni, R
    Giardina, B
    Lippa, S
    CLINICA CHIMICA ACTA, 1999, 285 (1-2) : 53 - 68
  • [7] ELIMINATION OF ZINC COPPER INTERMETALLIC INTERFERENCE IN THE DETERMINATION OF ZINC IN WASTEWATERS AND SEAWATER BY POTENTIOMETRIC STRIPPING ANALYSIS
    SCOLLARY, GR
    CARDWELL, TJ
    CATTRALL, RW
    NAN, CG
    VICENTEBECKETT, VA
    HAMILTON, IC
    RODEN, S
    ELECTROANALYSIS, 1993, 5 (08) : 685 - 689
  • [8] Resolution of differential potentiometric stripping analysis
    Garai, T
    Nagy, Z
    Meszaros, L
    Bartalits, L
    Locatelli, C
    Fagioli, F
    ELECTROANALYSIS, 1996, 8 (04) : 381 - 386
  • [9] Disposable screen-printed electrodes (SPE) mercury-free for lead detection
    Palchetti, I
    Upjohn, C
    Turner, APF
    Mascini, M
    ANALYTICAL LETTERS, 2000, 33 (07) : 1231 - 1246
  • [10] THEORY OF DERIVATIVE AND DIFFERENTIAL POTENTIOMETRIC STRIPPING ANALYSIS AND STRIPPING CHRONOPOTENTIOMETRY
    GARAI, T
    NAGY, Z
    MESZAROS, L
    BARTALITS, L
    LOCATELLI, C
    FAGIOLI, F
    ELECTROANALYSIS, 1992, 4 (09) : 899 - 904