Corrosion resistance and biocompatibility of Ni-free Zr-based bulk metallic glass for biomedical applications

被引:34
作者
Huang, Her-Hsiung [1 ,2 ,3 ]
Sun, Ying-Sui [4 ]
Wu, Chia-Ping [4 ]
Liu, Chia-Fei [4 ]
Liaw, Peter K. [5 ]
Kai, Wu [6 ]
机构
[1] Natl Yang Ming Univ, Dept Dent, Taipei 112, Taiwan
[2] Taipei City Hosp, Dept Dent, Taipei, Taiwan
[3] Taipei Vet Gen Hosp, Dept Stomatol, Taipei, Taiwan
[4] Natl Yang Ming Univ, Inst Oral Biol, Taipei 112, Taiwan
[5] Univ Tennessee, Dept Mat Sci & Engn, Knoxville, TN 37996 USA
[6] Natl Taiwan Ocean Univ, Inst Mat Engn, Keelung, Taiwan
关键词
Biocompatibility; Corrosion; Biomedical applications; ALLOY; AL; PROLIFERATION; ACCUMULATION; TI-6AL-4V; ROUGHNESS; ALUMINUM; BEHAVIOR; DISEASE; COPPER;
D O I
10.1016/j.intermet.2012.03.015
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Aim: Currently, the potential applications of Ni-free bulk metallic glasses (BMGs) in biomedical fields that have been reported in the literature are still limited. In this study, the corrosion resistance and biocompatibility of Ni-free, Zr-based Zr50Cu43Al7 BMGs in biological environments were investigated. Methods: The corrosion resistance was evaluated using potentiodynamic polarization curve measurements in simulated biological environments. The cytotoxicity was evaluated according to specification 10993-5 from the International Organization for Standardization (ISO). The protein (albumin) adsorption was evaluated using the bicinchoninic acid (BCA) assay. The adhesion and in situ migration of human bone marrow mesenchymal stem cells (hMSCs) were also evaluated. Results: The main component on the outermost surface of Zr50Cu43Al7 BMG was ZrO2, with trace amounts of Cu and Al oxides. The corrosion rates of Zr50Cu43Al7 in artificial saliva and in simulated body fluid were comparable with those of biomedical Ti metal in the same environments; however, pitting corrosion was observed on Zr50Cu43Al7 in both environments. The cytotoxicity analysis results showed that Zr50Cu43Al7 was nontoxic. Compared with Ti metal, Zr50Cu43Al7 had a higher level of protein adsorption and better cell adhesion and cell migration. Conclusion: Zr50Cu43Al7 BMG has the potential to be used in biomedical applications because of its corrosion resistance and cellular responses. However, further improvements to the pitting corrosion resistance of Zr50Cu43Al7 in biological environments should be made before proceeding to in vivo animal studies. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:139 / 143
页数:5
相关论文
共 28 条
[1]   Effects of roughness, fibronectin and vitronectin on attachment, spreading, and proliferation of human osteoblast-like cells (Saos-2) on titanium surfaces [J].
Degasne, I ;
Baslé, MF ;
Demais, V ;
Huré, G ;
Lesourd, M ;
Grolleau, B ;
Mercier, L ;
Chappard, D .
CALCIFIED TISSUE INTERNATIONAL, 1999, 64 (06) :499-507
[2]   Effect of surface roughness of the titanium alloy Ti-6Al-4V on human bone marrow cell response and on protein adsorption [J].
Deligianni, DD ;
Katsala, N ;
Ladas, S ;
Sotiropoulou, D ;
Amedee, J ;
Missirlis, YF .
BIOMATERIALS, 2001, 22 (11) :1241-1251
[3]   DEFECTIVE GALLIUM-TRANSFERRIN BINDING IN ALZHEIMER-DISEASE AND DOWN SYNDROME - POSSIBLE MECHANISM FOR ACCUMULATION OF ALUMINUM IN BRAIN [J].
FARRAR, G ;
ALTMANN, P ;
WELCH, S ;
WYCHRIJ, O ;
GHOSE, B ;
LEJEUNE, J ;
CORBETT, J ;
PRASHER, V ;
BLAIR, JA .
LANCET, 1990, 335 (8692) :747-750
[4]   Stress-Shielding Effect of Nitinol Swan-Like Memory Compressive Connector on Fracture Healing of Upper Limb [J].
Fu, Q. G. ;
Liu, X. W. ;
Xu, S. G. ;
Li, M. ;
Zhang, C. C. .
JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2009, 18 (5-6) :797-804
[5]   Biocompatibility Study of Zirconium-Based Bulk Metallic Glasses for Orthopedic Applications [J].
He, Wei ;
Chuang, Andrew ;
Cao, Zheng ;
Liaw, Peter K. .
METALLURGICAL AND MATERIALS TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 2010, 41A (07) :1726-1734
[6]   Re-passivation current of amorphous Zr65Al7.5Ni10Cu17.5 alloy in a Hanks' balanced solution [J].
Hiromoto, S ;
Hanawa, T .
ELECTROCHIMICA ACTA, 2002, 47 (09) :1343-1349
[7]   Effect of fluoride and albumin concentration on the corrosion behavior of Ti-6Al-4V alloy [J].
Huang, HH .
BIOMATERIALS, 2003, 24 (02) :275-282
[8]   Bio-corrosion study on zirconium-based bulk-metallic glasses [J].
Huang, Lu ;
Qiao, Dongchun ;
Green, Brandice A. ;
Liaw, Peter K. ;
Wang, Jianfeng ;
Pang, Shujie ;
Zhang, Tao .
INTERMETALLICS, 2009, 17 (04) :195-199
[9]  
IARC, 1999, IARC MON EV CARC RIS, V74
[10]   Electrochemical corrosion behavior of a Zr-based bulk-metallic glass [J].
Jiang, W. H. ;
Jiang, F. ;
Green, B. A. ;
Liu, F. X. ;
Liaw, P. K. ;
Choo, H. ;
Qiu, K. Q. .
APPLIED PHYSICS LETTERS, 2007, 91 (04)