Time-resolved imaging of contrast kinetics does not improve performance of follow-up MRA of embolized intracranial aneurysms

被引:3
作者
Serafin, Zbigniew [1 ]
Strzesniewski, Piotr [1 ]
Lasek, Wladyslaw [1 ]
Beuth, Wojciech [2 ]
机构
[1] Nicolaus Copernicus Univ, Dept Radiol & Diagnost Imaging, Coll Med, PL-85094 Bydgoszcz, Poland
[2] Nicolaus Copernicus Univ, Dept Neurosurg & Neurotraumatol, Coll Med, PL-85094 Bydgoszcz, Poland
来源
MEDICAL SCIENCE MONITOR | 2012年 / 18卷 / 07期
关键词
intracranial aneurysms; embolization; follow-up studies; magnetic resonance angiography; MAGNETIC-RESONANCE ANGIOGRAPHY; GUGLIELMI DETACHABLE COILS; CEREBRAL ANEURYSMS; ENDOVASCULAR TREATMENT; ENHANCED MRA; TRIAL ISAT; RETREATMENT; MULTICENTER;
D O I
10.12659/MSM.883199
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Methods: The use of contrast media and the time-resolved imaging of contrast kinetics (TRICKS) technique have some theoretical advantages over time-of-flight magnetic resonance angiography (TOF-MRA) in the follow-up of intracranial aneurysms after endovascular treatment. We prospectively compared the diagnostic performance of TRICKS and TOF-MRA with digital subtracted angiography (DSA) in the assessment of occlusion of embolized aneurysms. Material/Methods: Seventy-two consecutive patients with 72 aneurysms were examined 3 months after embolization. Test characteristics of TOF-MRA and TRICKS were calculated for the detection of residual flow. The results of quantification of flow were compared with weighted kappa. Intraobserver and interobserver reproducibility was determined. Results: The sensitivity of TOF-MRA was 85% (95% CI, 65-96%) and of TRICKS, 89% (95% CI, 70-97%). The specificity of both methods was 91% (95% CI, 79-98%). The accuracy of the flow quantification ranged from 0.76 (TOF-MRA) to 0.83 (TRICKS). There was no significant difference between the methods in the area under the ROC curve regarding both the detection and the quantification of flow. Intraobserver reproducibility was very good with both techniques (kappa, 0.86-0.89). The interobserver reproducibility was moderate for TOF-MRA and very good for TRICKS (kappa, 0.74-0.80). Conclusions: In this study, TOF-MRA and TRICKS presented similar diagnostic performance: therefore, the use of time-resolved contrast-enhanced MRA is not justified in the follow-up of embolized aneurysms.
引用
收藏
页码:MT60 / MT65
页数:6
相关论文
共 24 条
[11]   Three-Dimensional Dynamic Time-Resolved Contrast-Enhanced MRA Using Parallel Imaging and a Variable Rate k-Space Sampling Strategy in Intracranial Arteriovenous Malformations [J].
Petkova, Mina ;
Gauvrit, Jean-Yves ;
Trystram, Denis ;
Nataf, Francois ;
Godon-Hardy, Sylvie ;
Munier, Thierry ;
Oppenheim, Catherine ;
Meder, Jean-Francois .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (01) :7-12
[12]   Impact of International Subarachnoid Aneurysm Trial results on treatment of ruptured intracranial aneurysms in the United States Clinical article [J].
Qureshi, Adnan I. ;
Vazquez, Gabriela ;
Tariq, Nauman ;
Suri, M. Fareed K. ;
Lakshminarayan, Kamakshi ;
Lanzino, Giuseppe .
JOURNAL OF NEUROSURGERY, 2011, 114 (03) :834-841
[13]   Long-term follow-up of cerebral aneurysms after endovascular therapy-prediction and outcome of retreatment [J].
Ries, T. ;
Siemonsen, S. ;
Thomalla, G. ;
Grzyska, U. ;
Zeumer, H. ;
Fiehler, J. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2007, 28 (09) :1755-1761
[14]   DEFINING THE RISK OF RETREATMENT FOR ANEURYSM RECURRENCE OR RESIDUAL AFTER INITIAL TREATMENT BY ENDOVASCULAR COILING: A MULTICENTER STUDY [J].
Ringer, Andrew J. ;
Rodriguez-Mercado, Rafael ;
Veznedaroglu, Erol ;
Levy, Elad I. ;
Hanel, Ricardo A. ;
Mericle, Robert A. ;
Lopes, Demetrius K. ;
Lanzino, Giuseppe ;
Boulos, Alan S. .
NEUROSURGERY, 2009, 65 (02) :311-315
[15]   Endovascular treatment of unruptured aneurysms [J].
Roy, D ;
Milot, GV ;
Raymond, J .
STROKE, 2001, 32 (09) :1998-2004
[16]   Intracranial Aneurysms Treated with Coil Placement: Test Characteristics of Follow-up MR Angiography-Multicenter Study [J].
Schaafsma, Joanna D. ;
Velthuis, Birgitta K. ;
Majoie, Charles B. L. M. ;
van den Berg, Rene ;
Brouwer, Patrick A. ;
Barkhof, Frederik ;
Eshghi, Omid ;
de Kort, Gerard A. P. ;
Lo, Rob T. H. ;
Witkamp, Theo D. ;
Sprengers, Marieke E. S. ;
van Walderveen, Marianne A. ;
Bot, Joseph C. ;
Sanchez, Esther ;
Vandertop, W. Peter ;
van Gijn, Jan ;
Buskens, Erik ;
van der Graaf, Yolanda ;
Rinkel, Gabriel J. E. .
RADIOLOGY, 2010, 256 (01) :209-218
[17]   Time-resolved contrast-enhanced magnetic resonance angiography in the investigation of suspected intracranial dural arteriovenous fistula [J].
Schanker, Benjamin D. ;
Walcott, Brian P. ;
Nahed, Brian V. ;
Ogilvy, Christopher S. ;
Kiruluta, Andrew J. M. ;
Rabinov, James D. ;
Copen, William A. .
JOURNAL OF CLINICAL NEUROSCIENCE, 2011, 18 (06) :837-839
[18]   Evaluation of the Occlusion Status of Coiled Intracranial Aneurysms with MR Angiography at 3T: Is Contrast Enhancement Necessary? [J].
Sprengers, M. E. S. ;
Schaafsma, J. D. ;
van Rooij, W. J. ;
van den Berg, R. ;
Rinkel, G. J. E. ;
Akkerman, E. M. ;
Ferns, S. P. ;
Majoie, C. B. L. M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (09) :1665-1671
[19]   Endovascular treatment of experimental canine aneurysms: Feasibility with MR imaging guidance [J].
Strother, CM ;
Unal, O ;
Frayne, R ;
Turk, A ;
Omary, R ;
Korosec, FR ;
Mistretta, CA .
RADIOLOGY, 2000, 215 (02) :516-519
[20]   Usefulness of Contrast-Enhanced Magnetic Resonance Angiography for Follow-Up of Coil Embolization With the Enterprise Stent for Cerebral Aneurysms [J].
Takayama, Katsutoshi ;
Taoka, Toshiaki ;
Nakagawa, Hiroyuki ;
Myouchin, Kaoru ;
Wada, Takeshi ;
Sakamoto, Masahiko ;
Fukusumi, Akio ;
Iwasaki, Satoru ;
Kurokawa, Shinichiro ;
Kichikawa, Kimihiko .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (05) :568-572