Time-resolved imaging of contrast kinetics does not improve performance of follow-up MRA of embolized intracranial aneurysms

被引:3
作者
Serafin, Zbigniew [1 ]
Strzesniewski, Piotr [1 ]
Lasek, Wladyslaw [1 ]
Beuth, Wojciech [2 ]
机构
[1] Nicolaus Copernicus Univ, Dept Radiol & Diagnost Imaging, Coll Med, PL-85094 Bydgoszcz, Poland
[2] Nicolaus Copernicus Univ, Dept Neurosurg & Neurotraumatol, Coll Med, PL-85094 Bydgoszcz, Poland
来源
MEDICAL SCIENCE MONITOR | 2012年 / 18卷 / 07期
关键词
intracranial aneurysms; embolization; follow-up studies; magnetic resonance angiography; MAGNETIC-RESONANCE ANGIOGRAPHY; GUGLIELMI DETACHABLE COILS; CEREBRAL ANEURYSMS; ENDOVASCULAR TREATMENT; ENHANCED MRA; TRIAL ISAT; RETREATMENT; MULTICENTER;
D O I
10.12659/MSM.883199
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Methods: The use of contrast media and the time-resolved imaging of contrast kinetics (TRICKS) technique have some theoretical advantages over time-of-flight magnetic resonance angiography (TOF-MRA) in the follow-up of intracranial aneurysms after endovascular treatment. We prospectively compared the diagnostic performance of TRICKS and TOF-MRA with digital subtracted angiography (DSA) in the assessment of occlusion of embolized aneurysms. Material/Methods: Seventy-two consecutive patients with 72 aneurysms were examined 3 months after embolization. Test characteristics of TOF-MRA and TRICKS were calculated for the detection of residual flow. The results of quantification of flow were compared with weighted kappa. Intraobserver and interobserver reproducibility was determined. Results: The sensitivity of TOF-MRA was 85% (95% CI, 65-96%) and of TRICKS, 89% (95% CI, 70-97%). The specificity of both methods was 91% (95% CI, 79-98%). The accuracy of the flow quantification ranged from 0.76 (TOF-MRA) to 0.83 (TRICKS). There was no significant difference between the methods in the area under the ROC curve regarding both the detection and the quantification of flow. Intraobserver reproducibility was very good with both techniques (kappa, 0.86-0.89). The interobserver reproducibility was moderate for TOF-MRA and very good for TRICKS (kappa, 0.74-0.80). Conclusions: In this study, TOF-MRA and TRICKS presented similar diagnostic performance: therefore, the use of time-resolved contrast-enhanced MRA is not justified in the follow-up of embolized aneurysms.
引用
收藏
页码:MT60 / MT65
页数:6
相关论文
共 24 条
[1]   Evaluation of angiographic computed tomography in the follow-up after endovascular treatment of cerebral aneurysms-a comparative study with DSA and TOF-MRA [J].
Buhk, Jan-Hendrik ;
Kallenberg, Kai ;
Mohr, Alexander ;
Dechent, Peter ;
Knauth, Michael .
EUROPEAN RADIOLOGY, 2009, 19 (02) :430-436
[2]   Retreatment of ruptured cerebral aneurysms in patients randomized by coiling or clipping in the international subarachnoid aneurysm trial (ISAT) [J].
Campi, Adriana ;
Ramzi, Najib ;
Molyneux, Andrew J. ;
Summers, Paul E. ;
Kerr, Richard S. C. ;
Sneade, Mary ;
Yarnold, Julia A. ;
Rischmiller, Joan ;
Byrne, James V. .
STROKE, 2007, 38 (05) :1538-1544
[3]   Coiling of Intracranial Aneurysms A Systematic Review on Initial Occlusion and Reopening and Retreatment Rates [J].
Ferns, Sandra P. ;
Sprengers, Marieke E. S. ;
van Rooij, Willem Jan ;
Rinkel, Gabriel J. E. ;
van Rijn, Jeroen C. ;
Bipat, Shandra ;
Sluzewski, Menno ;
Majoie, Charles B. L. M. .
STROKE, 2009, 40 (08) :E523-E529
[4]   Intracranial aneurysms treated with Guglielmi detachable coils - Imaging follow-up with contrast-enhanced MR Angiography [J].
Gauvrit, JY ;
Leclerc, X ;
Caron, S ;
Taschner, CA ;
Lejeune, JP ;
Pruvo, JP .
STROKE, 2006, 37 (04) :1033-1037
[5]  
Gibbs GF, 2004, AM J NEURORADIOL, V25, P84
[6]   The impact of the international subarachnoid aneurysm trial (ISAT) on the management of aneurysmal subarachnoid haemorrhage in a neurosurgical unit in the UK [J].
Gnanalingham, KK ;
Apostolopoulos, V ;
Barazi, S ;
O'Neill, K .
CLINICAL NEUROLOGY AND NEUROSURGERY, 2006, 108 (02) :117-123
[7]   A Prospective Trial of 3T and 1.5T Time-of-Flight and Contrast-Enhanced MR Angiography in the Follow-Up of Coiled Intracranial Aneurysms [J].
Kaufmann, T. J. ;
Huston, J., III ;
Cloft, H. J. ;
Mandrekar, J. ;
Gray, L. ;
Bernstein, M. A. ;
Atkinson, J. L. ;
Kallmes, D. F. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (05) :912-918
[8]   MR angiography in the follow-up of intracranial aneurysms treated with Guglielmi detachable coils: systematic review and meta-analysis [J].
Kwee, Thomas C. ;
Kwee, Robert M. .
NEURORADIOLOGY, 2007, 49 (09) :703-713
[9]  
Maj E, 2010, POL J RADIOL, V75, P52
[10]   MR angiography of the intracranial vessels:: technical aspects and clinical applications [J].
Özsarlak, Ö ;
Van Goethem, JW ;
Maes, M ;
Parizel, PM .
NEURORADIOLOGY, 2004, 46 (12) :955-972