Analysis of exocytotic events recorded by amperometry

被引:263
作者
Mosharov, EV
Sulzer, D
机构
[1] Columbia Univ, Dept Neurol, New York, NY 10032 USA
[2] Columbia Univ, Dept Psychiat, New York, NY 10032 USA
[3] New York State Psychiat Inst & Hosp, Dept Neurosci, New York, NY 10032 USA
关键词
D O I
10.1038/nmeth782
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Amperometry is widely used to study exocytosis of neurotransmitters and hormones in various cell types. Analysis of the shape of the amperometric spikes that originate from the oxidation of monoamine molecules released during the fusion of individual secretory vesicles provides information about molecular steps involved in stimulation-dependent transmitter release. Here we present an overview of the methodology of amperometric signal processing, including (i) amperometric signal acquisition and filtering, (ii) detection of exocytotic events and determining spike shape characteristics, and (iii) data manipulation and statistical analysis. The purpose of this review is to provide practical guidelines for performing amperometric recordings of exocytotic activity and interpreting the results based on shape characteristics of individual release events.
引用
收藏
页码:651 / 658
页数:8
相关论文
共 59 条
[1]   The exocytotic event in chromaffin cells revealed by patch amperometry [J].
Albillos, A ;
Dernick, G ;
Horstmann, H ;
Almers, W ;
deToledo, GA ;
Lindau, M .
NATURE, 1997, 389 (6650) :509-512
[2]   High calcium concentrations shift the mode of exocytosis to the kiss-and-run mechanism [J].
Alés, E ;
Tabares, L ;
Poyato, JM ;
Valero, V ;
Lindau, M ;
de Toledo, GA .
NATURE CELL BIOLOGY, 1999, 1 (01) :40-44
[3]  
ALVAREZ DT, 1990, J GEN PHYSIOL, V95, P397, DOI DOI 10.1085/JGP.95.3.397
[4]   Correlation between vesicle quantal size and fusion pore release in chromaffin cell exocytosis [J].
Amatore, C ;
Arbault, S ;
Bonifas, I ;
Bouret, Y ;
Erard, M ;
Ewing, AG ;
Sombers, LA .
BIOPHYSICAL JOURNAL, 2005, 88 (06) :4411-4420
[5]   Interplay between membrane dynamics, diffusion and swelling pressure governs individual vesicular exocytotic events during release of adrenaline by chromaffin cells [J].
Amatore, C ;
Bouret, Y ;
Travis, ER ;
Wightman, RM .
BIOCHIMIE, 2000, 82 (05) :481-496
[6]   FAST-SCAN VOLTAMMETRY OF BIOGENIC-AMINES [J].
BAUR, JE ;
KRISTENSEN, EW ;
MAY, LJ ;
WIEDEMANN, DJ ;
WIGHTMAN, RM .
ANALYTICAL CHEMISTRY, 1988, 60 (13) :1268-1272
[7]  
BERG HC, 1983, RANDOM WALKS BIOL, P17
[8]   Effects of external osmotic pressure on vesicular secretion from bovine adrenal medullary cells [J].
Borges, R ;
Travis, ER ;
Hochstetler, SE ;
Wightman, RM .
JOURNAL OF BIOLOGICAL CHEMISTRY, 1997, 272 (13) :8325-8331
[9]   Detection of transmitter release with carbon fiber electrodes [J].
Bruns, D .
METHODS, 2004, 33 (04) :312-321
[10]   REAL-TIME MEASUREMENT OF TRANSMITTER RELEASE FROM SINGLE SYNAPTIC VESICLES [J].
BRUNS, D ;
JAHN, R .
NATURE, 1995, 377 (6544) :62-65