Patient dose in interventional radiology:: A European survey

被引:62
作者
Vano, E. [2 ]
Jarvinen, H. [1 ]
Kosunen, A. [1 ]
Bly, R. [1 ]
Malone, J. [3 ]
Dowling, A. [3 ]
Larkin, A. [3 ]
Padovani, R. [4 ]
Bosmans, H. [5 ]
Dragusin, O. [5 ]
Jaschke, W. [6 ]
Torbica, P. [6 ]
Back, C. [7 ]
Schreiner, A. [7 ]
Bokou, C. [7 ]
Kottou, S. [8 ]
Tsapaki, V. [9 ]
Jankowski, J. [10 ]
Papierz, S. [10 ]
Domienik, J. [10 ]
Werduch, A. [10 ]
Nikodemova, D. [11 ]
Salat, D. [12 ]
Kepler, K. [13 ]
Bor, M. D. [14 ]
Vassileva, J. [15 ]
Borisova, R. [15 ]
Pellet, S. [16 ]
Corbett, R. H. [17 ]
机构
[1] Radiat & Nucl Safety Author STUK, Helsinki, Finland
[2] Univ Complutense, Dept Radiol, E-28040 Madrid, Spain
[3] St James Hosp, Dublin 8, Ireland
[4] UO Fis Sanitaria, Udine, Italy
[5] Univ Hosp Gasthuisberg, Louvain, Belgium
[6] Univ Innsbruck Hosp, A-6020 Innsbruck, Austria
[7] Minist Hlth, Div Radiat Protect, Luxembourg, Luxembourg
[8] Univ Athens, Med Phys Sch, Athens, Greece
[9] Athens Gen Hosp, Athens, Greece
[10] Nofer Inst Occupat Med, Lodz, Poland
[11] Slovak Med Univ, Res Base, Bratislava, Slovakia
[12] Medicontrol, Trencin, Slovakia
[13] Univ Tartu, EE-50090 Tartu, Estonia
[14] Ankara Univ, Fac Engn, TR-06100 Ankara, Turkey
[15] Natl Ctr Radiobiol & Radiat Protect, Sofia, Bulgaria
[16] Natl Res Inst Radiobiol & Radiohyg, Budapest, Hungary
[17] Hairmyres Hosp, E Kilbride, Lanark, Scotland
关键词
D O I
10.1093/rpd/ncn024
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Patient doses for a few common fluoroscopy-guided procedures in interventional radiology (IR) ( excluding cardiology) were collected from a few radiological departments in 13 European countries. The major aim was to evaluate patient doses for the basis of the reference levels. In total, data for 20 procedures for about 1300 patients were collected. There were many-fold variations in the number of IR equipment and procedures per population, in the entrance dose rates, and in the patient dose data ( total dose area product or DAP, fluoroscopy time and number of frames). There was no clear correlation between the total DAP and entrance dose rate, or between the total DAP and fluoroscopy time, indicating that a number of parameters affect the differences. Because of the limited number of patients, preliminary reference levels were proposed only for a few procedures. There is a need to improve the optimisation of IR procedures and their definitions and grouping, in order to account for their different complexities.
引用
收藏
页码:39 / 45
页数:7
相关论文
共 9 条
[1]   How to set up and apply reference levels in fluoroscopy at a national level [J].
Aroua, A. ;
Rickli, H. ;
Stauffer, J.-C. ;
Schnyder, P. ;
Trueb, P. R. ;
Valley, J.-F. ;
Vock, P. ;
Verdun, F. R. .
EUROPEAN RADIOLOGY, 2007, 17 (06) :1621-1633
[2]  
Brambilla Marco, 2004, Radiol Med, V107, P408
[3]   Estimation of effective dose in some digital angiographic and interventional procedures [J].
Cruces, RR ;
García-Granados, J ;
Romero, FJD ;
Armas, JH .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (841) :42-47
[4]  
HART D, 2001, NRPBW4
[5]  
HART D, 2002, NRPBW14
[6]   A study of patient radiation doses in interventional radiological procedures [J].
McParland, BJ .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (842) :175-185
[7]   Radiation doses in interventional radiology procedures: The RAD-IR Study - Part I: Overall measures of dose [J].
Miller, DL ;
Balter, S ;
Cole, PE ;
Lu, HT ;
Schueler, BA ;
Geisinger, M ;
Berenstein, A ;
Albert, R ;
Georgia, JD ;
Noonan, PT ;
Cardella, JF ;
George, JS ;
Russell, EJ ;
Malisch, TW ;
Vogelzang, RL ;
Miller, GL ;
Anderson, J .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 14 (06) :711-727
[8]   PATIENT DOSE VALUES IN INTERVENTIONAL RADIOLOGY [J].
VANO, E ;
GONZALEZ, L ;
FERNANDEZ, JM ;
GUIBELALDE, E .
BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (815) :1215-1220
[9]  
VEIT R, 2003, INTRO DIAGNOSTIC REF