Monitoring of Indoor Radon Levels Around an Oil Refinery Using CR-39-Based Radon Detectors

被引:5
|
作者
Rahman, S. U. [1 ,2 ]
Malik, F. [3 ]
Matiullah [3 ]
Nasir, T. [4 ]
Anwar, J. [2 ]
机构
[1] Nucl Med Oncol & Radiotherapy Inst NORI, Dept Med Phys, Islamabad, Pakistan
[2] COMSATS Inst Informat Technol CIIT, Dept Phys, Islamabad, Pakistan
[3] PINSTECH, Div Phys, Islamabad, Pakistan
[4] Gomal Univ, Dept Phys, D I Khan, Pakistan
关键词
Internal dose; Natural radiation sources; Effective dose; CR-39-based radon detector; PUNJAB PROVINCE; LUNG-CANCER; PAKISTAN; DISTRICTS;
D O I
10.1177/1420326X11410583
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Contribution of radon and its decay products towards the total effective dose has been reported to be more than 50% and is a second leading cause of the lung cancer after cigarette smoking. It is an established fact that besides soil and rocks, naturally occurring radio nuclides are also associated with the petroleum extracted from the sedimentary deposits. Therefore, radon measurement around oil refineries is desirable. In this regard, an indoor radon measurement study was carried out in 40 dwellings which were situated in the vicinity of an oil refinery in the Rawalpindi district using CR-39-based radon detectors. For comparison, indoor radon levels were also measured in 40 dwellings situated at a greater distance (>2 km) from the refinery. The maximum measured indoor radon concentration was found to be 190 +/- 6 Bq.m(-3) whilst the minimum recorded concentration was 12 +/- 7 Bq.m(-3). The mean radon concentration in the dwellings surveyed was 57 +/- 29 Bq.m(-3). No significant difference was observed in the average indoor radon levels in the dwellings situated near the oil refinery premises when compared with those further away. From the measured radon concentrations, an annual effective dose was calculated to be 0.9 +/- 0.1 mSv which is below the ICRP recommended value.
引用
收藏
页码:452 / 457
页数:6
相关论文
共 15 条
  • [1] Determination of the calibration factor for CR-39 based indoor radon detector
    Matiullah
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 298 (01) : 369 - 373
  • [2] Assessment of radon levels in some cosmetics using CR-39 nuclear detector
    Shabaan, Doaa H.
    EL-Araby, EntesarH.
    Al-Nagaar, Tayseer I.
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2024, 17 (02)
  • [3] Measurement of indoor radon levels in Erbil capital by using solid state nuclear track detectors
    Mansour, HH
    Khdar, SP
    Abdulla, HY
    Muhamad, NQ
    Othman, MM
    Qader, S
    RADIATION MEASUREMENTS, 2005, 40 (2-6) : 544 - 547
  • [4] The study of indoor radon in the urban dwellings using plastic track detectors
    M. Shakir Khan
    M. Zubair
    Deepak Verma
    A. H. Naqvi
    Ameer Azam
    M. K. Bhardwaj
    Environmental Earth Sciences, 2011, 63 : 279 - 282
  • [5] The study of indoor radon in the urban dwellings using plastic track detectors
    Khan, M. Shakir
    Zubair, M.
    Verma, Deepak
    Naqvi, A. H.
    Azam, Ameer
    Bhardwaj, M. K.
    ENVIRONMENTAL EARTH SCIENCES, 2011, 63 (02) : 279 - 282
  • [6] Indoor Radon concentration and its Health Risks in Selected Locations in Iraqi Kurdistan using CR-39 NTDs
    Ismail, Asaad. H.
    Jaafar, Mohamad S.
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [7] Estimation of concentration and exposure doses due to radon by using CR-39 plastic track detectors in the residences of Sudhnuti, Azad Kashmir, Pakistan
    Rafique, Muhammad
    Rahman, Saeed Ur
    Akram, Muhammad
    Matiullah
    ENVIRONMENTAL EARTH SCIENCES, 2012, 66 (04) : 1225 - 1232
  • [8] Radiological risk estimation from indoor radon, thoron, and their progeny concentrations using nuclear track detectors
    Gogoi, Pranjal Protim
    Barooah, Debajyoti
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2022, 194 (12)
  • [9] Measurement of indoor radon and thoron in the dwellings of Faizabad city using plastic track detectors
    Verma, Deepak
    Khan, M. Shakir
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2013, 51 (04) : 219 - 222
  • [10] Factors affecting use of CR-39 surface monitor technology to estimate past exposure to indoor radon
    Mahaffey, JA
    Parkhurst, MA
    Hui, TE
    Brownson, RC
    Alavanja, MCR
    JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 1996, 6 (04): : 425 - 437