A sensitive and selective bulk optode for determination of Hg(II) based on hexathiacyclooctadecane and chromoionophore V

被引:40
作者
Ensafi, Ali A. [1 ]
Fouladgar, Masoud [1 ]
机构
[1] Isfahan Univ Technol, Dept Chem, Esfahan 8415683111, Iran
关键词
Bulk optode; Chromoionophore V; Hexathiacyclooctadecane; Mercury(II); OPTICAL SENSOR; SUBNANOMOLAR DETECTION; MERCURY DETERMINATION; MEMBRANE; ELECTRODES; IONOPHORES; PORPHYRIN; SILVER;
D O I
10.1016/j.snb.2008.12.029
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive new bulk optical sensor (optode) for mercury(II) is described. This optode is based on the interaction of hexathiacyclooctadecane with Hg(II) in plasticized polyvinyl chloride (PVC) membrane incorporating chromoionophore V as lipophilic H+-selective indicator. The membranes were cast onto glass substrates and used for the determination of mercury ions in aqueous solutions. The PVC membrane composition plus the other experimental variables were optimized. With the proposed sensor, mercury(H) can be measured in the range of 2.1 x 10(-7) to 1.2 x 10(-4) mol L-1 with a limit ofdetection 2.0 x 10(-7) mol L-1 Hg(H). The influence of potential interfering ions on the determination Hg(H) was studied. The sensor showed excellent selectivity for Hg(H) with respect to several common alkali, alkaline earth and transition metal ions. The results obtained for the determination of mercury ions in water samples using the proposed optode was found to be comparable with the well-established furnace atomic absorption method. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:326 / 331
页数:6
相关论文
共 39 条
[1]   Development of an Hg(II) fibre-optic sensor for aqueous environmental monitoring [J].
Ahmad, M ;
Hamzah, H ;
Marsom, ES .
TALANTA, 1998, 47 (02) :275-283
[2]   Monitoring Pb2+ with optical sensing films [J].
Anticó, E ;
Lerchi, M ;
Rusterholz, B ;
Achermann, N ;
Badertscher, M ;
Valiente, M ;
Pretsch, E .
ANALYTICA CHIMICA ACTA, 1999, 388 (03) :327-338
[3]   SELECTIVITY OF ION-SENSITIVE BULK OPTODES [J].
BAKKER, E ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1805-1812
[4]   DETERMINATION OF COMPLEX-FORMATION CONSTANTS OF NEUTRAL CATION-SELECTIVE IONOPHORES IN SOLVENT POLYMERIC MEMBRANES [J].
BAKKER, E ;
WILLER, M ;
LERCHI, M ;
SEILER, K ;
PRETSCH, E .
ANALYTICAL CHEMISTRY, 1994, 66 (04) :516-521
[5]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[6]   Irreversible optical sensor for mercury determination based on tetraarylborate decomposition [J].
Cano-Raya, C. ;
Fernandez-Ramos, M. D. ;
Gomez-Sanchez, J. ;
Capitan-Vallvey, L. F. .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 117 (01) :135-142
[7]   SILVER-SELECTIVE MEMBRANE ELECTRODES USING ACYCLIC DITHIA BENZENE DERIVATIVE NEUTRAL CARRIERS - COMPARISON WITH RELATED MACROCYCLIC-COMPOUNDS [J].
CASABO, J ;
FLOR, T ;
ROMERO, MI ;
TEIXIDOR, F ;
PEREZJIMENEZ, C .
ANALYTICA CHIMICA ACTA, 1994, 294 (02) :207-213
[8]   Development of a mercury ion-selective optical sensor based on fluorescence quenching of 5,10,15,20-tetraphenylporphyrin [J].
Chan, WH ;
Yang, RH ;
Wang, KM .
ANALYTICA CHIMICA ACTA, 2001, 444 (02) :261-269
[9]   Optode membrane for determination of nicotine via generation of its bromoethane derivative [J].
Choi, MMF ;
Wu, XJ ;
Li, YR .
ANALYTICAL CHEMISTRY, 1999, 71 (07) :1342-1349
[10]   Signaling recognition events with fluorescent sensors and switches [J].
de Silva, AP ;
Gunaratne, HQN ;
Gunnlaugsson, T ;
Huxley, AJM ;
McCoy, CP ;
Rademacher, JT ;
Rice, TE .
CHEMICAL REVIEWS, 1997, 97 (05) :1515-1566