Direct electron transfer and electrocatalytic properties of immobilized hemoglobin onto glassy carbon electrode modified with ionic-liquid/titanium-nitride nanoparticles: Application to nitrite detection

被引:32
作者
Saadati, Shaghayegh [1 ]
Salimi, Abdollah [1 ,2 ]
Hallaj, Rahman [1 ,2 ]
Rostami, Amin [1 ]
机构
[1] Univ Kurdistan, Dept Chem, Sanandaj 6617715175, Iran
[2] Univ Kurdistan, Res Ctr Nanotechnol, Sanandaj 6617715175, Iran
关键词
Amine-terminated/ionic liquid; Titanium nitride/nanoparticles; Hemoglobin; Direct electron transfer; Nitrite; Sensor; DIRECT ELECTROCHEMISTRY; DIRECT VOLTAMMETRY; COMPOSITE FILM; AMPEROMETRIC BIOSENSOR; SURFACTANT FILMS; LIQUID; NANOTUBES; MYOGLOBIN; REDUCTION; OXIDE;
D O I
10.1016/j.snb.2013.10.062
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Glassy carbon (GC) electrode modified with covalently attached amine-terminated ionic liquid (NH2-IL) and titanium nitrite nanoparticles (TiNnp) was used as support for immobilization of hemoglobin (Hb) protein. The presence of well-defined and nearly reversible CV peaks with E-o' of -0.03 V (vs. Ag/AgCl) indicated the successful immobilization of Hb on GC/TiNnp/NH2-IL surface. The surface coverage of Hb immobilized on nanocomposite film (F), and heterogeneous electron transfer rate constant (k(s)) were 5.12 (+/-0.05) x 10(-11) mol cm(-2) and 5.10 +/- 0.10 s(-1) respectively, indicating high loading capacity of nanocomposite for direct electron transfer of Hb on the electrode surface. Moreover, the GC/TiNnp/NH2-IL/Hb electrode revealed excellent electrocatalytic activity toward nitrite reduction. This sensor exhibited fast amperometric response with sensitivity of 0.027 +/- 0.009 mu A/mu M and limit of detection of 0.10 +/- 0.010 mu M at the concentration range up to 2 mM. The calculated Michaelis-Menten constant (K-M) of 0.065 (+/-0.030)mM indicated that Hb immobilized onto the nanocomposite film retained its native activity. The sensor also showed good stability, reproducibility and long lifetime and it was successfully applied for nitrite detection in real samples with obtained satisfactory results. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:625 / 633
页数:9
相关论文
共 51 条
[1]   Dual Templating Synthesis of Mesoporous Titanium Nitride Microspheres [J].
Bang, Jin Ho ;
Suslick, Kenneth S. .
ADVANCED MATERIALS, 2009, 21 (31) :3186-+
[2]   Renewable Ceramic (TiN) Ring Electrode in Stripping Voltammetry. Determination of Pb(II) Without Removal of Oxygen [J].
Bas, B. ;
Piech, R. ;
Ziemnicka, M. ;
Reczynski, W. ;
Robotka, M. .
ELECTROANALYSIS, 2009, 21 (16) :1773-1780
[3]   Novel amperometric biosensor based on composite film assembled by polyelectrolyte-surfactant polymer, carbon nanotubes and hemoglobin [J].
Chen, Liang ;
Lu, Gongxuan .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 121 (02) :423-429
[4]   Direct electrochemistry of myoglobin based on ionic liquid-clay composite films [J].
Dai, Zong ;
Xiao, Yun ;
Yu, Xiaozhi ;
Mai, Zhibin ;
Zhao, Xiaojuan ;
Zou, Xiaoyong .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (06) :1629-1634
[5]   Electrospun hemoglobin microbelts based biosensor for sensitive detection of hydrogen peroxide and nitrite [J].
Ding, Yu ;
Wang, Ying ;
Li, Baikun ;
Lei, Yu .
BIOSENSORS & BIOELECTRONICS, 2010, 25 (09) :2009-2015
[6]   Direct electrochemistry and electrocatalysis of hemoglobin in composite film based on ionic liquid and NiO microspheres with different morphologies [J].
Dong, Sheying ;
Zhang, Penghui ;
Liu, Hui ;
Li, Nan ;
Huang, Tinglin .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (10) :4082-4087
[7]   Electron-transfer reactivity and enzymatic activity of hemoglobin in a SP sephadex membrane [J].
Fan, CH ;
Wang, HY ;
Sun, S ;
Zhu, DX ;
Wagner, G ;
Li, GX .
ANALYTICAL CHEMISTRY, 2001, 73 (13) :2850-2854
[8]   Direct electrochemistry of myoglobin in a layer-by-layer film on an ionic liquid modified electrode containing CeO2 nanoparticles and hyaluronic acid [J].
Gao, Ruifang ;
Zheng, Jianbin ;
Zheng, Xiaohui .
MICROCHIMICA ACTA, 2011, 174 (3-4) :273-280
[9]   Electrochemical oxidation of primary amine in ionic liquid media: Formation of organic layer attached to electrode surface [J].
Ghilane, Jalal ;
Martin, Pascal ;
Randriamahazaka, Hyacinthe ;
Lacroix, Jean-Christophe .
ELECTROCHEMISTRY COMMUNICATIONS, 2010, 12 (02) :246-249
[10]   Direct electron transfer of haemoglobin and myoglobin in methanol and ethanol at didodecyldimethylammonium bromide modified pyrolytic graphite electrodes [J].
Ivanova, EV ;
Magner, E .
ELECTROCHEMISTRY COMMUNICATIONS, 2005, 7 (04) :323-327