Modelling and comparison analysis of grid-connected DFIG-based wind farm in weak grid

被引:9
作者
Yan, Cai [1 ]
Yao, Wei [1 ]
Wen, Jianfeng [1 ]
Fang, Jiakun [1 ]
Ai, Xiaomeng [1 ]
Wen, Jinyu [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Peoples R China
关键词
stators; power generation control; wind power plants; rotors; asynchronous generators; shafts; eigenvalues and eigenfunctions; phase locked loops; grid-connected DFIG-based wind farm; weak grid; modelling comparison analysis; grid-connected double-fed induction generator; linear system analysis; PLL dynamics; eigenvalue analysis; FED INDUCTION GENERATOR; STABILITY ANALYSIS; IMPEDANCE-MODEL; DAMPING CONTROL; CONVERTERS; TURBINES;
D O I
10.1049/iet-rpg.2019.1382
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study proposes a generic method for modelling and comparison analysis of grid-connected double-fed induction generator (DFIG)-based wind farms in a weak grid. A detailed model of DFIG in a weak grid is established and used as a benchmark. Specifically, the detailed model consists of the mechanical part, generator part, rotor side converter, and phase-locked loop (PLL). Two simplified models of grid-connected DFIG-based wind farms in a weak grid are compared with the detailed model to investigate the mechanism of sub-synchronous oscillation (SSO) as well as the influential factors through linear system analysis. The first simplified model ignores shafting dynamics, stator flux dynamics, and PLL dynamics. The same assumptions are used in the latter, except that PLL dynamics are considered. Time-domain simulation and eigenvalue analysis are used to verify the accuracy of the simplified models. The block diagrams of the linearised system are derived based on the proposed model, and the oscillation mechanism is explained by linear system analysis. Through eigenvalue analysis and the root locus method, the influences of the parameters of the DFIG and its controllers on the system stability are identified and analysed.
引用
收藏
页码:2406 / 2415
页数:10
相关论文
共 50 条
  • [31] Stability Analysis of Grid-connected Inverter in Weak Grid Systems
    Chen, Xin
    Gong, Chun Yin
    Cheng, Lin
    ADVANCES IN POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 614-615 : 1514 - 1518
  • [32] Transient Control of DFIG-Based Wind Power Plants in Compliance With the Australian Grid Code
    Mohseni, Mansour
    Islam, Syed M.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (06) : 2813 - 2824
  • [33] Enhancement of Fault Ride Through Capabilities for Grid-Connected DFIG-Based Wind Farms using Nonlinear Adaptive Backstepping Controllers
    Roy, T. K.
    Mahmud, M. A.
    Islam, S. N.
    Oo, Amanullah M. T.
    Muttaqi, K. M.
    2018 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, DRIVES AND ENERGY SYSTEMS (PEDES), 2018,
  • [34] A Novel Protection Method to Enhance the Grid-Connected Capability of DFIG based on Wind Turbines
    Dai, Le Van
    IETE JOURNAL OF RESEARCH, 2024, 70 (02) : 2047 - 2063
  • [35] Operation of Grid-Connected PV-Battery-Wind Driven DFIG Based System
    Bhattacharyya, Sudip
    Puchalapalli, Sambasivaiah
    Singh, Bhhn
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2022, 58 (05) : 6448 - 6458
  • [36] Torsional vibration characteristic study of the grid-connected DFIG wind turbine
    Yu, Songtao
    Xie, Da
    Wu, Wangping
    Gu, Chenghong
    Lie, Furong
    INTERNATIONAL CONFERENCE ON ENERGY ENGINEERING AND ENVIRONMENTAL PROTECTION (EEEP2016), 2017, 52
  • [37] Adaptive Neural PLL for Grid-connected DFIG Synchronization
    Bechouche, Ali
    Abdeslam, Djaffar Ould
    Otmane-Cherif, Tahar
    Seddiki, Hamid
    JOURNAL OF POWER ELECTRONICS, 2014, 14 (03) : 608 - 620
  • [38] Stability analysis of CHB photovoltaic grid-connected inverter in weak grid
    Yang S.
    Zhang X.
    Mao W.
    Hu Y.
    Wang M.
    Wang F.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2022, 43 (01): : 398 - 405
  • [39] Transient Behavior Analysis for a 2 MW Grid-Connected DFIG-based WECS under Partial Symmetrical Voltage Dips
    Cheikh, Ridha
    Menacer, Arezki
    Belmili, Hocine
    2017 9TH IEEE-GCC CONFERENCE AND EXHIBITION (GCCCE), 2018, : 749 - 754
  • [40] Emergency power balance control based on proactive motor operation of DFIG-based wind turbines for sending grid stability
    Zheng, Di
    Ouyang, Jinxin
    Xiong, Xiaofu
    Wang, Ying
    IET RENEWABLE POWER GENERATION, 2020, 14 (19) : 4063 - 4070