Correction of PMT position effect for a lead-scintillating fiber electromagnetic calorimeter

被引:34
作者
Li Zu-Hao [1 ,2 ]
Wang Ling-Yu [1 ]
Xu Wei-Wei [1 ,2 ]
Chen Guo-Ming [1 ]
Lu Yu-Sheng [1 ]
Chen He-Sheng [1 ]
机构
[1] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
[2] Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
electromagnetic calorimeter; photo multiplier tube; position effect; energy resolution;
D O I
10.1088/1674-1137/37/2/026201
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
The position effect of the photoelectron multiplier tube (PMT) of the electromagnetic calorimeter (ECAL) of Alpha Magnetic Spectrometer-02 (AMS-02) has been studied with beam-test data. The reconstructed deposited energy in a layer versus incidence position in the cell can be described by Gaussian distribution, maximum and minimum value can be obtained when the particle passes across the center and the edge of a cell respectively. The distribution can be used to correct the effect of incidence position on energy reconstruction. Much better energy resolution was acquired be got with the correction, for 100 GeV electrons, energy resolution improved from 3% to 2%.
引用
收藏
页数:4
相关论文
共 8 条
[1]  
Antonelli M, 1977, NUCL PHYS B, V54, P14
[2]   The gamma-ray detection capabilities of the Alpha Magnetic Spectrometer [J].
Battiston, R ;
Biasini, M ;
Fiandrini, E ;
Petrakis, J ;
Salamon, MH .
ASTROPARTICLE PHYSICS, 2000, 13 (01) :51-74
[3]   The AMS-02 electromagnetic calorimeter [J].
Cadoux, F ;
Cervelli, F ;
Chambert-Hermel, V ;
Chen, G ;
Chen, H ;
Coignet, G ;
Di Falco, S ;
Dubois, JM ;
Falchini, E ;
Franzoso, A ;
Fougeron, D ;
Fouque, N ;
Galeotti, S ;
Girard, L ;
Goy, C ;
Hermel, R ;
Incagli, M ;
Kossakowski, R ;
Lieunard, B ;
Liu, Y ;
Liu, Z ;
Lomtadze, T ;
Maestro, P ;
Marrocchesi, PS ;
Paoletti, R ;
Pilo, F ;
Rosier-Lees, S ;
Spinella, F ;
Turini, N ;
Valle, G ;
Venanzoni, G ;
Vialle, JP ;
Yu, Z ;
Zhuang, H .
NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2002, 113 :159-165
[4]   Results of 2007 test beam of AMS-02 Electromagnetic Calorimeter [J].
Di Falco, Stefano .
ADVANCES IN SPACE RESEARCH, 2010, 45 (01) :112-122
[5]  
Kossakowski R, 20020103 AMS
[6]  
Li ZH, 2004, HIGH ENERG PHYS NUC, V28, P521
[7]  
LI Zu-Hao, 2004, HEP NP, V28, P1182
[8]   MONTE-CARLO CALCULATION OF PHOTON-INITIATED ELECTROMAGNETIC SHOWERS IN LEAD GLASS [J].
LONGO, E ;
SESTILI, I .
NUCLEAR INSTRUMENTS & METHODS, 1975, 128 (02) :283-307