Hydride generation-point discharge microplasma-optical emission spectrometry for the determination of trace As, Bi, Sb and Sn

被引:55
作者
Li, Mengtian [1 ]
Deng, Yujia [2 ]
Zheng, Chengbin [1 ]
Jiang, Xiaoming [2 ]
Hou, Xiandeng [1 ,2 ]
机构
[1] Sichuan Univ, Coll Chem, Chengdu 610064, Sichuan, Peoples R China
[2] Sichuan Univ, Analyt & Testing Ctr, Chengdu 610064, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
DIELECTRIC-BARRIER DISCHARGE; ATOMIC FLUORESCENCE SPECTROMETRY; PHOTOCHEMICAL VAPOR GENERATION; CAPACITIVELY COUPLED PLASMA; CATHODE GLOW-DISCHARGE; ON-A-CHIP; ELEMENTAL ANALYSIS; ATMOSPHERIC-PRESSURE; AQUEOUS SAMPLES; GC DETECTOR;
D O I
10.1039/c6ja00341a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A miniaturized optical emission spectrometer (OES) with point discharge (PD) helium-hydrogen microplasma as an excitation source and hydride generation (HG) for sample introduction was constructed for the determination of trace As, Bi, Sb and Sn. Hydrogen generated from the HG process usually consumes part of the excitation capability of a microplasma, but here it was used to effectively minimize the background spectral emission of the microplasma, thus enabling more spectral emission lines with less background spectral interferences for analysis of more elements. In addition, separation of analyte-containing hydride from the sample solvent and matrix prior to excitation in the microplasma was achieved with better sensitivity, selectivity and stability. The compact PD was constructed using two tapered tungsten electrodes powered by alternating current (ac) high voltage, and emission spectra were recorded with a hand-held charge coupled device (CCD) spectrometer. Limits of detection (LODs) of 7, 1, 5 and 2 mu g L-1 and relative standard deviation (RSD) of less than 5% were obtained for As, Bi, Sb and Sn, using 234.984 nm, 306.770 nm, 259.805 nm and 317.504 nm as the analytical lines, respectively. The potential application of this miniaturized instrumentation was also demonstrated by successfully analyzing several Certified Reference Materials (CRMs) with satisfactory results.
引用
收藏
页码:2427 / 2433
页数:7
相关论文
共 36 条
[1]   Spatial Emission Profiles for Flagging Matrix Interferences in Axial-Viewing Inductively Coupled Plasma-Atomic Emission Spectrometry: 2. Statistical Protocol [J].
Chan, George C. -Y. ;
Hieftje, Gary M. .
ANALYTICAL CHEMISTRY, 2013, 85 (01) :58-65
[2]   Direct determination of sodium, potassium, chromium and vanadium in biodiesel fuel by tungsten coil atomic emission spectrometry [J].
Dancsak, Stacia E. ;
Silva, Sidnei G. ;
Nobrega, Joaquim A. ;
Jones, Bradley T. ;
Donati, George L. .
ANALYTICA CHIMICA ACTA, 2014, 806 :85-90
[3]   A microwave-induced plasma based on microstrip technology and its use for the atomic emission spectrometric determination of mercury with the aid of the cold-vapor technique [J].
Engel, U ;
Bilgiç, AM ;
Haase, O ;
Voges, E ;
Broekaert, JAC .
ANALYTICAL CHEMISTRY, 2000, 72 (01) :193-197
[4]   Microplasmas for analytical spectrometry [J].
Franzke, J ;
Kunze, K ;
Miclea, M ;
Niemax, K .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (07) :802-807
[5]   Simultaneous determination of As and Sb in soil using hydride generation capacitively coupled plasma microtorch optical emission spectrometry - comparison with inductively coupled plasma optical emission spectrometry [J].
Frentiu, Tiberiu ;
Butaciu, Sinziana ;
Ponta, Michaela ;
Darvasi, Eugen ;
Senila, Marin ;
Petreus, Dorin ;
Frentiu, Maria .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (10) :1880-1888
[6]   Miniaturized Dielectric Barrier Discharge Carbon Atomic Emission Spectrometry with Online Microwave-Assisted Oxidation for Determination of Total Organic Carbon [J].
Han, Bingjun ;
Jiang, Xiaoming ;
Hou, Xiandeng ;
Zheng, Chengbin .
ANALYTICAL CHEMISTRY, 2014, 86 (13) :6214-6219
[7]   Dielectric Barrier Discharge Carbon Atomic Emission Spectrometer: Universal GC Detector for Volatile Carbon-Containing Compounds [J].
Han, Bingjun ;
Jiang, Xiaoming ;
Hou, Xiandeng ;
Zheng, Chengbin .
ANALYTICAL CHEMISTRY, 2014, 86 (01) :936-942
[8]   Flowing and Nonflowing Liquid Electrode Discharge Microplasma for Metal Ion Detection by Optical Emission Spectrometry [J].
He, Qian ;
Zhu, Zhenli ;
Hu, Shenghong .
APPLIED SPECTROSCOPY REVIEWS, 2014, 49 (03) :249-269
[9]   Critical evaluation of the application of photochemical vapor generation in analytical atomic spectrometry [J].
He, Yihua ;
Hou, Xiandeng ;
Zheng, Chengbin ;
Sturgeon, Ralph E. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 388 (04) :769-774
[10]   Dielectric Barrier Discharge in Analytical Spectrometry [J].
Hu, Jing ;
Li, Wei ;
Zheng, Chengbin ;
Hou, Xiandeng .
APPLIED SPECTROSCOPY REVIEWS, 2011, 46 (05) :368-387