Silver nanowire array sensor for sensitive and rapid detection of H2O2

被引:163
作者
Kurowska, E. [1 ]
Brzozka, A. [2 ]
Jarosz, M. [1 ]
Sulka, G. D. [1 ]
Jaskula, M. [1 ]
机构
[1] Jagiellonian Univ, Dept Phys Chem & Electrochem, PL-30060 Krakow, Poland
[2] AGH Univ Sci & Technol, Fac Nonferrous Met, PL-30059 Krakow, Poland
关键词
Silver; Nanowires; Hydrogen peroxide; Sensor; HYDROGEN-PEROXIDE; ELECTRODE; NANOPARTICLES; BIOSENSOR; REDUCTION; GLUCOSE; ACID; ANODIZATION; ALUMINUM; CANCER;
D O I
10.1016/j.electacta.2013.01.077
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A novel amperometric sensor based on silver nanowire (Ag NW) array was fabricated and used for a rapid and sensitive detection of hydrogen peroxide (H2O2). The 50-nm in diameter nanowires were synthesized by electrodeposition of silver in the nanopores of anodic aluminum oxide (AAO) template. At an applied potential of -0.2V vs. SCE, the developed Ag NW array electrode exhibited electrocatalytic response toward the reduction of H2O2 at a very wide range of H2O2 concentrations and three significantly linear sections in a calibration plot were observed. The determination of H2O2 with the highest sensitivity of about 0.0266 mu A cm(-2) mu M-1 is possible in the concentration range from 0.1 mM to 3.1 mM with a detection limit of 29.2 mu M. Moreover, the proposed sensor exhibited relatively high sensibility, good reproducibility, and satisfying long-term stability. The developed Ag NW array sensor excluded the interference from substances typically present in the biological samples such as ascorbic acid (AA), uric acid (UA), ethanol (EtOH), glucose (G) and oxalate ions. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:439 / 447
页数:9
相关论文
共 51 条
[1]   Hydrogen peroxide determination in pharmaceutical formulations and cosmetics using a new catalase biosensor [J].
Campanella, L ;
Roversi, R ;
Sammartino, MP ;
Tomassetti, M .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 18 (1-2) :105-116
[2]   Photochemical elimination of phenols and cod in industrial wastewaters [J].
Chen, J ;
Rulkens, WH ;
Bruning, H .
WATER SCIENCE AND TECHNOLOGY, 1997, 35 (04) :231-238
[3]   Electrochemical sensor based on Prussian blue nanorods and gold nanochains for the determination of H2O2 [J].
Chen, Shihong ;
Ma, Liping ;
Yuan, Ruo ;
Chai, Yaqin ;
Xiang, Yun ;
Wang, Chengyan .
EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2011, 232 (01) :87-95
[4]  
Galus Z., 1976, FUNDAMENTALS ELECTRO, P313
[5]  
Giorgio M, 2007, NAT REV MOL CELL BIO, V8, p722A
[6]   A new amperometric nanostructured sensor for the analytical determination of hydrogen peroxide [J].
Guascito, M. R. ;
Filippo, E. ;
Malitesta, C. ;
Manno, D. ;
Serra, A. ;
Turco, A. .
BIOSENSORS & BIOELECTRONICS, 2008, 24 (04) :1057-1063
[7]   Effect of Nanoporous Structure on Enhanced Electrochemical Reaction [J].
Han, Ji-Hyung ;
Lee, Eonji ;
Park, Sejin ;
Chang, Rakwoo ;
Chung, Taek Dong .
JOURNAL OF PHYSICAL CHEMISTRY C, 2010, 114 (21) :9546-9553
[8]   ELECTROCHEMICAL-BEHAVIOR OF H2O2 AT AG IN HCLO4 AQUEOUS-SOLUTION [J].
HONDA, M ;
KODERA, T ;
KITA, H .
ELECTROCHIMICA ACTA, 1986, 31 (03) :377-383
[9]   The Aβ peptide of Alzheimer's disease directly produces hydrogen peroxide through metal ion reduction [J].
Huang, XD ;
Atwood, CS ;
Hartshorn, MA ;
Multhaup, G ;
Goldstein, LE ;
Scarpa, RC ;
Cuajungco, MP ;
Gray, DN ;
Lim, J ;
Moir, RD ;
Tanzi, RE ;
Bush, AI .
BIOCHEMISTRY, 1999, 38 (24) :7609-7616
[10]   CYTOTOXICITY OF MEDICAL MATERIALS STERILIZED WITH VAPOR-PHASE HYDROGEN-PEROXIDE [J].
IKARASHI, Y ;
TSUCHIYA, T ;
NAKAMURA, A .
BIOMATERIALS, 1995, 16 (03) :177-183