Determination of volatile organic compounds in exhaled breath of heart failure patients by needle trap micro-extraction coupled with gas chromatography-tandem mass spectrometry

被引:57
作者
Biagini, D. [1 ]
Lomonaco, T. [1 ]
Ghimenti, S. [1 ]
Bellagambi, F. G. [1 ]
Onor, M. [2 ]
Scali, M. C. [3 ]
Barletta, V. [3 ]
Marzilli, M. [3 ]
Salvo, P. [4 ]
Trivella, M. G. [4 ]
Fuoco, R. [1 ]
Di Francesco, F. [1 ]
机构
[1] Univ Pisa, Dept Chem & Ind Chem, Pisa, Italy
[2] CNR, Inst Chem Organometall Cpds, Pisa, Italy
[3] Univ Pisa, Dept Surg Med & Mol Pathol & Crit Care Med, Pisa, Italy
[4] CNR, Inst Clin Physiol, Pisa, Italy
关键词
needle trap micro-extraction; GC-MS/MS; breath analysis; heart failure; VOCs; THERMAL-DESORPTION; KETONE-BODIES; COLLECTION; BIOMARKERS; DIAGNOSIS; ACETONE; SAMPLES; DEVICE; AIR;
D O I
10.1088/1752-7163/aa94e7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The analytical performances of needle trap micro-extraction (NTME) coupled with gas chromatography-tandem mass spectrometry were evaluated by analyzing a mixture of twenty-two representative breath volatile organic compounds (VOCs) belonging to different chemical classes (i.e. hydrocarbons, ketones, aldehydes, aromatics and sulfurs). NTME is an emerging technique that guarantees detection limits in the pptv range by pre-concentrating low volumes of sample, and it is particularly suitable for breath analysis. For most VOCs, detection limits between 20 and 500 pptv were obtained by pre-concentrating 25 ml of a humidified standard gas mixture at a flow rate of 15 ml min(-1). For all compounds, inter- and intra-day precisions were always below 15%, confirming the reliability of the method. The procedure was successfully applied to the analysis of exhaled breath samples collected from forty heart failure (HF) patients during their stay in the University Hospital of Pisa. The majority of patients (about 80%) showed a significant decrease of breath acetone levels (a factor of 3 or higher) at discharge compared to admission (acute phase) in correspondence to the improved clinical conditions during hospitalization, thus making this compound eligible as a biomarker of HF exacerbation.
引用
收藏
页数:13
相关论文
共 51 条
[1]   Headspace needle-trap analysis of priority volatile organic compounds from aqueous samples: Application to the analysis of natural and waste waters [J].
Alonso, Monica ;
Cerdan, Laura ;
Godayol, Anna ;
Antico, Enriqueta ;
Sanchez, Juan M. .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (45) :8131-8139
[2]  
Amann A., 2014, J BREATH RES, V8, P1
[3]   Simply breath-taking? Developing a strategy for consistent breath sampling [J].
Beauchamp, J. D. ;
Pleil, J. D. .
JOURNAL OF BREATH RESEARCH, 2013, 7 (04)
[4]   On the use of Tedlar® bags for breath-gas sampling and analysis [J].
Beauchamp, Jonathan ;
Herbig, Jens ;
Gutmann, Rene ;
Hansel, Armin .
JOURNAL OF BREATH RESEARCH, 2008, 2 (04)
[5]   Breath analysis: Potential for clinical diagnosis and exposure assessment [J].
Cao, WQ ;
Duan, YX .
CLINICAL CHEMISTRY, 2006, 52 (05) :800-811
[6]  
Ceccarini A, 2012, ANAL TECHNIQUES CLIN, P651, DOI [10.1002/9781118271858.ch23, DOI 10.1002/9781118271858.CH23]
[7]   Effects of ventilation on the collection of exhaled breath in humans [J].
Cope, KA ;
Watson, MT ;
Foster, WM ;
Sehnert, SS ;
Risby, TH .
JOURNAL OF APPLIED PHYSIOLOGY, 2004, 96 (04) :1371-1379
[8]   A review of the volatiles from the healthy human body [J].
Costello, B. de Lacy ;
Amann, A. ;
Al-Kateb, H. ;
Flynn, C. ;
Filipiak, W. ;
Khalid, T. ;
Osborne, D. ;
Ratcliffe, N. M. .
JOURNAL OF BREATH RESEARCH, 2014, 8 (01)
[9]   State of the Art: Newer biomarkers in heart failure [J].
de Boer, Rudolf A. ;
Daniels, Lori B. ;
Maisel, Alan S. ;
Januzzi, James L., Jr. .
EUROPEAN JOURNAL OF HEART FAILURE, 2015, 17 (06) :559-569
[10]   Adsorbent materials commonly used in air analysis for adsorptive enrichment and thermal desorption of volatile organic compounds [J].
Dettmer, K ;
Engewald, W .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (06) :490-500