摘要
Purpose: This meta-analysis aims to evaluate the differences in performance of posterior capsular opacification (PCO) between hydrophobic acrylic intraocular lens (IOLs) and hydrophilic acrylic IOLs. Setting: Tianjin Medical University, Tianjin Eye Hospital, Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin, China. Design: Systematic review of randomized controlled trials (RCTs) or meta-analysis. Methods: An electronic literature search was performed using the PubMed, EMBASE and Cochrane Library database before May in 2013 to identify prospective RCTs comparing hydrophobic acrylic IOLs and hydrophilic acrylic IOLs in patients after phacoemulsification with IOL implantation with a follow-up time of at least 1 year. Pertinent studies were selected by meeting predefined criteria and reviewed systematically by meta-analysis. The PCO scores and YAG capsulotomy rate, as indicator of PCO, were measured and discussed in a meta-analysis. Standardized mean differences (SMD), relative risk ratio (RR), and the pooled estimates were computed according to a random effect model or fixed effect model. Results: Nine prospective RCTs involving 861 eyes were included in the current meta-analysis. The hydrophobic acrylic IOLs were favored and the pooled SMD of PCO severity was 1.72 (95% confidence interval (CI), 0.20 to 1.23, P = 0.0002) and 1.79 (95% CI, 0.95 to 2.64, P<0.0001) with 1-year follow-up and 2-year follow-up respectively. The pooled RR of Nd:YAG laser capsulotomy rates at postoperative 2-year follow-up was 6.96 (95% CI, 3.69 to 13.11, P<0.00001) comparing hydrophilic acrylic IOLs with hydrophobic acrylic IOLs. Conclusions: Compared with hydrophilic acrylic IOLs, the hydrophobic acrylic IOLs showed superior reduction in rates of PCO and laser capsulotomy in 2-year follow-up. More RCTs with standard methods for longer follow-up are needed to validate the association.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Hydrophobic versus hydrophilic acrylic intraocular lens on posterior capsule opacification: a Meta-analysis
    Wu, Qiong
    Li, Yan
    Wu, Lian
    Wang, Cong-Yi
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2022, 15 (06) : 997 - 1004
  • [2] Hydrophobic versus double-square-edged hydrophilic foldable acrylic intraocular lens: Effect on posterior capsule opacification
    Iwase, Takeshi
    Nishi, Yutarou
    Oveson, Brian C.
    Jo, Young-Joon
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (06) : 1060 - 1068
  • [3] Comparison of posterior capsule opacification with hydrophobic acrylic and hydrophilic acrylic intraocular lenses
    Vasavada, Abhay R.
    Raj, Shetal M.
    Shah, Alpesh
    Shah, Gauri
    Vasavada, Viraj
    Vasavada, Vaishali
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (06) : 1050 - 1059
  • [4] Comparison of hydrophobic and hydrophilic intraocular lens in preventing posterior capsule opacification after cataract surgery: An updated meta-analysis
    Zhao, Yang
    Yang, Ke
    Li, Jiaxin
    Huang, Yang
    Zhu, Siquan
    MEDICINE, 2017, 96 (44)
  • [5] Posterior Capsule Opacification after Cataract Surgery via Implantation with Hydrophobic Acrylic Lens Compared with Silicone Intraocular Lens: A Systematic Review and Meta-Analysis
    Kwon, Ye Rin
    Hwang, Yoo Na
    Kim, Sung Min
    JOURNAL OF OPHTHALMOLOGY, 2022, 2022
  • [6] Hydrophilic acrylic intraocular lens optic opacification in a diabetic patient
    Park, Dae Il
    Ha, Sung Woo
    Park, Seong Bae
    Lew, Helen
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2011, 55 (06) : 595 - 599
  • [7] Comparison of posterior capsular opacification in heparin-surface-modified hydrophilic acrylic and hydrophobic acrylic intraocular lenses
    Kang, Seungbum
    Choi, Jin A.
    Joo, Choun-Ki
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2009, 53 (03) : 204 - 208
  • [8] Misdiagnosed opacification of a hydrophobic acrylic intraocular lens
    Ahmed, Syed Naqib
    Shahid, Syed Mohammed
    Nanavaty, Mayank A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (10) : 1512 - 1514
  • [9] The Effect of Single-Piece Hydrophobic Acrylic Intraocular Lenses on the Development of Posterior Capsule Opacification
    Praveen, Mamidipudi R.
    Shah, Gauri D.
    Vasavada, Abhay R.
    Dave, Khyati H.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 160 (03) : 470 - 478
  • [10] Postoperative diffuse opacification of a hydrophilic acrylic intraocular lens: analysis of an explant
    Cavallini, Gian Maria
    Volante, Veronica
    Campi, Luca
    De Maria, Michele
    Fornasari, Elisa
    Urso, Giancarlo
    INTERNATIONAL OPHTHALMOLOGY, 2018, 38 (04) : 1733 - 1739