Endoscopic Ultrasound Fine-Needle Aspiration versus Fine-Needle Biopsy for Lymph Node Diagnosis: A Large Multicenter Comparative Analysis

被引:26
作者
Hourneaux de Moura, Diogo Turiani [1 ,2 ,3 ]
McCarty, Thomas R. [1 ,2 ]
Jirapinyo, Pichamol [1 ,2 ]
Ribeiro, Igor Braga [3 ]
Ayala Farias, Galileu Ferreira [3 ]
Ryou, Marvin [1 ,2 ]
Lee, Linda S. [1 ,2 ]
Thompson, Christopher C. [1 ,2 ]
机构
[1] Brigham & Womens Hosp, Div Gastroenterol Hepatol & Endoscopy, 75 Francis St, Boston, MA 02115 USA
[2] Harvard Med Sch, Boston, MA 02115 USA
[3] Univ Sao Paulo, Dept Gastroenterol, Hosp Clin Fac Med, Sao Paulo, SP, Brazil
关键词
Endoscopic ultrasound; Endoscopic ultrasound-guided tissue acquisition; Fine-needle aspiration; Fine-needle biopsy; Lymph nodes; EUS-GUIDED FNA; ON-SITE; CYTOLOGY; IMPACT; ACCURACY; LESIONS; CANCER; TISSUE; YIELD;
D O I
10.5946/ce.2019.170
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background/Aims: Endoscopic ultrasound fine-needle aspiration (EUS-FNA) is preferred for sampling of lymph nodes (LNs) adjacent to the gastrointestinal wall; however, fine-needle biopsy (FNB) may provide improved diagnostic outcomes. This study aimed to evaluate the comparative efficacy and safety of FNA versus FNB for LN sampling. Methods: This was a multicenter retrospective study of prospectively collected data to evaluate outcomes of EUS-FNA and EUS-FNB for LN sampling. Characteristics analyzed included sensitivity, specificity, accuracy, the number of needle passes, diagnostic adequacy of rapid on-site evaluation (ROSE), cell-block analysis, and adverse events. Results: A total of 209 patients underwent EUS-guided LN sampling. The mean lesion size was 16.22 +/- 8.03 mm, with similar sensitivity and accuracy between FNA and FNB ([67.21% vs. 75.00%, respectively, p=0.216] and [78.80% vs. 83.17%, respectively, p=0.423]). The specificity of FNB was better than that of FNA (100.00% vs. 93.62%, p=0.01). The number of passes required for diagnosis was not different. Abdominal and peri-hepatic LN location demonstrated FNB to have a higher sensitivity (81.08% vs. 64.71%, p=0.031 and 80.95% vs. 58.33%, p=0.023) and accuracy (88.14% vs. 75.29%, p=0.053 and 88.89% vs. 70.49%, p=0.038), respectively. ROSE was a significant predictor for accuracy (odds ratio, 5.16; 95% confidence interval, 1.15-23.08; p=0.032). No adverse events were reported in either cohort. Conclusions: Both EUS-FNA and EUS-FNB are safe for the diagnosis of LNs. EUS-FNB is preferred for abdominal LN sampling. EUS-FNA+ROSE was similar to EUS-FNB alone, showing better diagnosis for EUS-FNB than traditional FNA. While ROSE remained a significant predictor for accuracy, due to its poor availability in most centers, its use may be limited to cases with previous inconclusive diagnoses.
引用
收藏
页码:600 / 610
页数:11
相关论文
共 32 条
  • [1] In memoriam: Fine-needle aspiration, birth: Fine-needle biopsy: The changing trend in endoscopic ultrasound-guided tissue acquisition
    Bang, Ji Young
    Kirtane, Sachin
    Krall, Konrad
    Navaneethan, Udayakumar
    Hasan, Muhammad
    Hawes, Robert
    Varadarajulu, Shyam
    [J]. DIGESTIVE ENDOSCOPY, 2019, 31 (02) : 197 - 202
  • [2] Campbell I, 2007, STAT MED, V26, P3661, DOI 10.1002/sim.2832
  • [3] Endoscopic ultrasound-guided fine needle aspiration is superior to lymph node echofeatures: A prospective evaluation of mediastinal and peri-intestinal lymphadenopathy
    Chen, VK
    Eloubeidi, MA
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2004, 99 (04) : 628 - 633
  • [4] An evaluation of risk factors for inadequate cytology in EUS-guided FNA of pancreatic tumors and lymph nodes
    Cleveland, Patrick
    Gill, Kanwar Rupinder S.
    Coe, Susan G.
    Woodward, Timothy A.
    Raimondo, Massimo
    Jamil, Laith
    Gross, Seth A.
    Heckman, Michael G.
    Crook, Julia E.
    Wallace, Michael B.
    [J]. GASTROINTESTINAL ENDOSCOPY, 2010, 71 (07) : 1194 - 1199
  • [5] New ultrasound techniques for lymph node evaluation
    Cui, Xin-Wu
    Jenssen, Christian
    Saftoiu, Adrian
    Ignee, Andre
    Dietrich, Christoph F.
    [J]. WORLD JOURNAL OF GASTROENTEROLOGY, 2013, 19 (30) : 4850 - 4860
  • [6] The importance of endoscopic ultrasound fine-needle aspiration in the diagnosis of solid pseudopapillary tumor of the pancreas: two case reports
    De Moura D.T.H.
    Coronel M.
    Ribeiro I.B.
    Farias G.F.A.
    Choez M.A.
    Rocha R.
    Toscano M.P.
    De Moura E.G.H.
    [J]. Journal of Medical Case Reports, 12 (1) : 107
  • [7] Hourneaux De Moura Diogo Turiani, 2017, Rev. gastroenterol. Perú, V37, P370
  • [8] De Moura Diogo Turiani Hourneaux, 2016, J Med Case Rep, V10, P332
  • [9] Endoscopic ultrasound: Elastographic lymph node evaluation
    Dietrich, Christoph F.
    Jenssen, Christian
    Arcidiacono, Paolo G.
    Cui, Xin-Wu
    Giovannini, Marc
    Hocke, Michael
    Iglesias-Garcia, Julio
    Saftoiu, Adrian
    Sun, Siyu
    Chiorean, Liliana
    [J]. ENDOSCOPIC ULTRASOUND, 2015, 4 (03) : 176 - 190
  • [10] Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline - Updated January 2017
    Dumonceau, Jean-Marc
    Deprez, Pierre H.
    Jenssen, Christian
    Iglesias-Garcia, Julio
    Larghi, Alberto
    Vanbiervliet, Geoffroy
    Aithal, Guruprasad P.
    Arcidiacono, Paolo G.
    Bastos, Pedro
    Carrara, Silvia
    Czako, Laszlo
    Fernandez-Esparrach, Gloria
    Fockens, Paul
    Gines, Angels
    Havre, Roald F.
    Hassan, Cesare
    Vilmann, Peter
    van Hooft, Jeanin E.
    Polkowski, Marcin
    [J]. ENDOSCOPY, 2017, 49 (07) : 695 - 714