Balloon-augmented Onyx embolization of cerebral arteriovenous malformations using a dual-lumen balloon: a multicenter experience

被引:47
作者
Spiotta, Alejandro M. [1 ]
James, Robert F. [2 ,3 ]
Lowe, Stephen R. [1 ]
Vargas, Jan [1 ]
Turk, Aquilla S. [4 ]
Chaudry, M. Imran [4 ]
Bhalla, Tarun [5 ]
Janjua, Rashid M. [6 ]
Delaney, John J. [7 ]
Quintero-Wolfe, Stacey [6 ]
Turner, Raymond D. [1 ]
机构
[1] Med Univ S Carolina, Dept Neurosci, Div Neurosurg, Charleston, SC 29425 USA
[2] Univ Louisville, Sch Med, Dept Neurol Surg, Louisville, KY 40292 USA
[3] E Carolina Univ, Dept Surg, Brody Sch Med, Div Neurosurg, Greenville, NC USA
[4] Med Univ S Carolina, Dept Radiol, Charleston, SC 29425 USA
[5] Geisinger Med Ctr, Dept Neurosurg, Danville, PA 17822 USA
[6] Wake Forest Univ, Sch Med, Dept Neurosurg, Winston Salem, NC 27109 USA
[7] E Carolina Univ, Brody Sch Med, Greenville, NC USA
关键词
Arteriovenous Malformation; BRAIN; HEMORRHAGE;
D O I
10.1136/neurintsurg-2014-011285
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Introduction Conventional Onyx embolization of cerebral arteriovenous malformations (AVMs) requires lengthy procedure and fluoroscopy times to form an adequate proximal plug' which allows forward nidal penetration while preventing reflux and non-targeted embolization. We review our experience with balloon-augmented Onyx embolization of cerebral AVMs using a dual-lumen balloon catheter technique designed to minimize these challenges. Methods Retrospectively acquired data for all balloon-augmented cerebral AVM embolizations performed between 2011 and 2014 were obtained from four tertiary care centers. For each procedure, at least one Scepter C balloon catheter was advanced into the AVM arterial pedicle of interest and Onyx embolization was performed through the inner lumen after balloon inflation via the outer lumen. Results Twenty patients underwent embolization with the balloon-augmented technique over 24 discreet treatment episodes. There were 37 total arterial pedicles embolized with the balloon-augmented technique, a mean of 1.9 per patient (range 1-5). The treated AVMs were heterogeneous in their location and size (mean 3.31.6cm). Mean fluoroscopy time for each procedure was 48 +/- 26min (28min per embolized pedicle). Two Scepter C balloon catheter-related complications (8.3% of embolization sessions, 5.4% of pedicles embolized) were observed: an intraprocedural rupture of a feeding pedicle and fracture and retention of a catheter fragment. Conclusions This multicenter experience represents the largest reported series of balloon-augmented Onyx embolization of cerebral AVMs. The technique appears safe and effective in the treatment of AVMs, allowing more efficient and controlled injection of Onyx with a decreased risk of reflux and decreased fluoroscopy times.
引用
收藏
页码:721 / 727
页数:7
相关论文
共 17 条
[1]   Incidence and prevalence of intracranial vascular malformations in Olmsted County, Minnesota, 1965 to 1992 [J].
Brown, RD ;
Wiebers, DO ;
Torner, JC ;
OFallon, WN .
NEUROLOGY, 1996, 46 (04) :949-952
[2]   Endovascular Advances for Brain Arteriovenous Malformations [J].
Crowley, R. Webster ;
Ducruet, Andrew F. ;
McDougall, Cameron G. ;
Albuquerque, Felipe C. .
NEUROSURGERY, 2014, 74 :S74-S82
[3]   Treatment of arteriovenous malformations of the brain [J].
Hartmann, Andreas ;
Mast, Henning ;
Choi, Jae H. ;
Stapf, Christian ;
Mohr, Jay P. .
CURRENT NEUROLOGY AND NEUROSCIENCE REPORTS, 2007, 7 (01) :28-34
[4]   Complications of embolization of arteriovenous malformations of the brain [J].
Haw, CS ;
terBrugge, K ;
Willinsky, R ;
Tomlinson, G .
JOURNAL OF NEUROSURGERY, 2006, 104 (02) :226-232
[5]   Endovascular Balloon-Assisted Embolization of Intracranial and Cervical Arteriovenous Malformations Using Dual-Lumen Coaxial Balloon Microcatheters and Onyx: Initial Experience [J].
Jagadeesan, Bharathi D. ;
Grigoryan, Mikayel ;
Hassan, Ameer E. ;
Grande, Andrew W. ;
Tummala, Ramachandra P. .
NEUROSURGERY, 2013, 73 :238-243
[6]  
Michelson WJ., 1978, CLIN NEUROSURG, V26, P307
[7]   AN ANALYSIS OF THE VENOUS DRAINAGE SYSTEM AS A FACTOR IN HEMORRHAGE FROM ARTERIOVENOUS-MALFORMATIONS [J].
MIYASAKA, Y ;
YADA, K ;
OHWADA, T ;
KITAHARA, T ;
KURATA, A ;
IRIKURA, K .
JOURNAL OF NEUROSURGERY, 1992, 76 (02) :239-243
[8]   Onyx embolization using dual-lumen balloon catheter: Initial experience and technical note [J].
Paramasivam, Srinivasan ;
Niimi, Yasunari ;
Fifi, Johanna ;
Berenstein, Alejandro .
JOURNAL OF NEURORADIOLOGY, 2013, 40 (04) :294-302
[9]   Factors that predict the bleeding risk of cerebral arteriovenous malformations [J].
Pollock, BE ;
Flickinger, JC ;
Lunsford, LD ;
Bissonette, DJ ;
Kondziolka, D .
STROKE, 1996, 27 (01) :1-6
[10]   Balloon augmented Onyx embolization utilizing a dual lumen balloon catheter: utility in the treatment of a variety of head and neck lesions [J].
Spiotta, Alejandro M. ;
Miranpuri, Amrendra S. ;
Vargas, Jan ;
Magarick, Jordan ;
Turner, Raymond D. ;
Turk, Aquilla S. ;
Chaudry, M. Imran .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2014, 6 (07) :547-555