Characteristics of Tin Oxide Chromatographic Detector for Dissolved Gases Analysis of Transformer Oil

被引:21
作者
Fan, Jingmin [1 ]
Liu, Zhe [1 ]
Meng, Anbo [1 ]
Yin, Hao [1 ]
Sun, Qiuqin [2 ]
Bin, Feng [2 ]
Jiang, Qinji [3 ]
机构
[1] Guangdong Univ Technol, Sch Automat, Guangzhou 510012, Guangdong, Peoples R China
[2] Hunan Univ, Coll Elect & Informat Engn, Changsha 410082, Hunan, Peoples R China
[3] State Grid Hunan Maintenance Co, Changsha 41007, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Power transformer; chromatography; dissolved gas analysis; nano-tin oxide detector; FAULT-DIAGNOSIS; HYDROGEN; SENSOR; DECOMPOSITION; METHANE; SYSTEM; NI;
D O I
10.1109/ACCESS.2019.2928869
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The analysis of dissolved gases in insulation oil is of great significance to transformer status evaluation. In this paper, a chromatographic detector based on the nano-tin oxide fiber as well as a chromatography system is developed. The mechanism of the sensor for detecting six component feature gases (i.e., H-2, CO, CH4, C2H4, C2H6, and C2H2) in transformer oil is expounded, on basis of which the exponent-logarithmic model between conductance and gas concentrations is proposed. Then, the repeatability and accuracy of the nano-tin oxide detectors are tested. The experimental results show that the gases mixture can be separated well by the designed gas chromatography system, and six component gases mixture detection can be realized by the developed detector. Meanwhile, by using the proposed model, high precision of dissolved gas measurement can be achieved, thus the validity of the presented model is verified. Moreover, compared with other chromatographic detectors, i.e., flame ionization detector, the only carrier gas needed for the nano-tin oxide chromatographic detector is the synthetic air, the hardware cost and complexity of system are reduced largely, showing promising applicable value in the engineering practice.
引用
收藏
页码:94012 / 94020
页数:9
相关论文
共 50 条
[31]   A Study on the Generation Characteristics of Decomposition Gases for Insulating Oil of Transformer Bushing [J].
Jun, Tae-Hyun ;
Kwak, Byeong-Sub ;
Kim, Ah-Reum ;
Lim, Byung-Hun ;
Park, Hyun-Joo .
Transactions of the Korean Institute of Electrical Engineers, 2025, 74 (02) :326-331
[32]   A GA-fuzzy modeling approach for pattern recognition of dissolved gases in power transformer oil [J].
Guo, HJ ;
Liu, JH ;
Lin, SF .
ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, :5022-5025
[33]   A New Method to Detect Dissolved Gases in Transformer Oil using NIR-IR Spectroscopy [J].
Abu Bakar, Norazhar ;
Abu-Siada, A. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (01) :409-419
[34]   Competitive adsorption of gases dissolved in transformer oil on Co-doped ZnO (0001) surface [J].
Xiao, Gongwei ;
Chen, Weigen ;
Peng, Shangyi ;
Yu, Chutian ;
Jiang, Zikai .
COMPUTATIONAL MATERIALS SCIENCE, 2018, 142 :72-81
[35]   Effectiveness assessment of selected graphical techniques for the interpretation of measured concentrations of gases dissolved in transformer oil [J].
Piotrowski, Tomasz .
PRZEGLAD ELEKTROTECHNICZNY, 2019, 95 (08) :57-60
[36]   Transformer Familial Defect Detection Method Based on SVM Improved by Apriori Algorithm-Based on Analysis of Dissolved Gases in Oil [J].
Li Shiyong ;
Zhang Lijuan ;
Shi Yan ;
Yang Junqiu ;
Zhang Hongru ;
Yao Yang ;
Wang Kai ;
Li Qingquan .
2019 2ND INTERNATIONAL CONFERENCE ON ELECTRICAL MATERIALS AND POWER EQUIPMENT (ICEMPE 2019), 2019, :544-548
[37]   Application of Raman Spectroscopy for the Analysis of Methyl Acetate Dissolved in Transformer Oil [J].
Gu, Zhaoliang ;
Zhu, Wenbing ;
Zhu, Mengzhao ;
Wu, Di ;
Zhou, Jiabin ;
Wang, Jian ;
Zhu, Qingdong ;
Chen, Weigen .
2018 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2018,
[38]   Dissolved Gas Analysis of Transformer Oil Based on Deep Belief Networks [J].
Liang, Yu ;
Xu, Yao-Yu ;
Wan, Xin-Shu ;
Li, Yuan ;
Liu, Ning ;
Zhang, Guan-Jun .
2018 12TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS (ICPADM 2018), 2018, :825-828
[39]   Interpretable Transformer Fault Diagnosis Based on SHAP Value and Dissolved Gas Analysis of Transformer Oil [J].
Liao C. ;
Yang J. ;
Qiu Z. ;
Hu X. ;
Zeng Q. ;
Huang Z. .
Dianwang Jishu/Power System Technology, 2024, 48 (04) :1752-1761
[40]   Gas Sensing Performances of ZnO Hierarchical Structures for Detecting Dissolved Gases in Transformer Oil: A Mini Review [J].
Zhang, He ;
Chen, Wei-Gen ;
Li, Yan-Qiong ;
Song, Zi-Hao .
FRONTIERS IN CHEMISTRY, 2018, 6