Acidified pressurized hot water for the continuous extraction of cadmium and lead from plant materials prior to ETAAS

被引:21
作者
Morales-Muñoz, S [1 ]
Luque-García, JL [1 ]
de Castro, MDL [1 ]
机构
[1] Univ Cordoba, Dept Analyt Chem, E-14071 Cordoba, Spain
关键词
plant materials; ETAAS; hot water extraction;
D O I
10.1016/S0584-8547(02)00216-1
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Acidified and pressurized hot water is proposed for the continuous leaching of Cd and Pb from plants prior to determination by electrothermal atomic absorption spectrometry. Beech leaves (a certified reference material-CRM 100-where the analytes were not certified) were used for optimizing the method by a multivariate approach. The samples (0.5 g) were subjected to dynamic extraction with water modified with 1% v/v HNO, at 250 degreesC as leachant. A kinetics study was performed in order to know the pattern of the extraction process. The method was validated with a CRM (olive leaves, 062 from the BCR) where the analytes had been certified. The agreement between the certified values and those found using the proposed method demonstrates its usefulness. The repeatability and within-laboratory reproducibility were 3.7 and 2.3% for Cd and 1.04% and 6.3% for Pb, respectively. The precision of the method, together with its efficiency, rapidity, and environmental acceptability, makes it a good alternative for the determination of trace metals in plant material. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:159 / 165
页数:7
相关论文
共 21 条
[1]  
Adriano D.C., 1980, TRACE ELEMENTS AQUAT
[2]   Microwave assisted extraction for trace element analysis of plant materials by ICP-AES [J].
Borkowska-Burnecka, J .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (06) :633-637
[3]  
Carlosena A., 1994, QUIM ANAL, V13, P214
[4]  
de Castro MDL, 1999, TRAC-TREND ANAL CHEM, V18, P708
[5]   Micelle formation for improvement of continuous subcritical water extraction of polycyclic aromatic hydrocarbons in soil prior to high-performance liquid chromatography-fluorescence detection [J].
Fernández-Pérez, V ;
de Castro, MDL .
JOURNAL OF CHROMATOGRAPHY A, 2000, 902 (02) :357-367
[6]   Continuous liquid-liquid extraction using modified subcritical water for the demetalisation of used industrial oils [J].
Fernández-Pérez, V ;
Jiménez-Carmona, MM ;
de Castro, MDL .
ANALYTICA CHIMICA ACTA, 2001, 433 (01) :47-52
[7]   Continuous extraction with acidified subcritical water of arsenic, selenium and mercury from coal prior to on-line derivatisation-atomic fluorescence detection [J].
Fernández-Pérez, V ;
Jiménez-Carmona, MM ;
de Castro, MDL .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (11) :1761-1765
[8]  
FERNANDEZPEREZ V, 2000, ANALYST, V125, P185
[9]   Static-dynamic pressurized hot water extraction coupled to on-line filtration-solid-phase extraction-high-performance liquid chromatography-post-column derivatization-fluorescence detection for the analysis of N-methylcarbamates in foods [J].
Herrera, MC ;
Prados-Rosales, RC ;
Luque-García, JL ;
de Castro, MDL .
ANALYTICA CHIMICA ACTA, 2002, 463 (02) :189-197
[10]   Acidified subcritical water extraction of major ash-forming elements from coal [J].
Jiménez-Carmona, MM ;
Fernández-Pérez, V ;
Gualda-Bueno, MJ ;
Cabanás-Espejo, JM ;
de Castro, MDL .
ANALYTICA CHIMICA ACTA, 1999, 395 (1-2) :113-118