Magnitude and Direction of Pulsatile Displacement Forces Acting on Thoracic Aortic Endografts

被引:74
|
作者
Figueroa, C. Alberto [2 ]
Taylor, Charles A. [1 ,2 ]
Chiou, Allen J. [2 ]
Yeh, Victoria [2 ]
Zarins, Christopher K. [1 ]
机构
[1] Stanford Univ, Med Ctr, Dept Surg, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
关键词
displacement forces; aortic endografts; endograft migration; thoracic aortic aneurysm; angulation and curvature; computational fluid dynamics; ENDOVASCULAR STENT-GRAFTS; BLOOD-FLOW; ANEURYSM SAC; ARTERIES; REPAIR; MOVEMENT; PRESSURE; FIXATION; TRIAL;
D O I
10.1583/09-2738.1
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To assess 3-dimensional (3D) pulsatile displacement forces (DF) acting on thoracic endografts using 3D computational techniques. Methods: A novel computational method to quantitate the pulsatile 3D flow and pressure fields and aortic wall dynamics in patient-specific anatomical models based on cardiac-gated computed tomography (CT) scans was used to construct simulations of the proximal and mid-descending thoracic aorta. Endografts of varying lengths and diameters were implanted in these patient-specific models. The magnitude and direction of the DF vector were calculated and expressed in Newtons (N). This DF included the effects of both the pressure and shearing stresses of blood. Results: The magnitude of DF increased with endografts of increasing diameter and length. A 36-mm endograft in the mid-descending aorta had a mean DF of 21.7 N with a peak systolic DF of 27.8 N and an end-diastolic DF of 16.7 N. Conversely, a 30-mm endograft in the proximal descending aorta had a mean DF of 14.9 N, with peak systolic and end-diastolic DFs of 18.9 and 11.5, respectively. The orientation of the DF acting on the endograft varied depending on aortic angulation and tortuosity; in general, the vector was perpendicular to the greater curvature of the endograft rather than along the downstream longitudinal centerline axis of the aorta as is commonly believed. The DF vector pointed primarily in the cranial direction for the proximal descending endograft and in the sideways direction for the mid-descending endograft simulation. Furthermore, it was shown that elevated pressure plays an important role in the magnitude and direction of DF; an increase in mean blood pressure resulted in an approximately linearly proportional increase in DF. Conclusion: The orientation of the DF varies depending on curvature and location of the endograft, but in all instances, it is in the cranial rather than caudal direction on axial imaging. This is counter to the intuitive notion that displacement forces act in the downward direction of blood flow. Therefore, we postulate that migration of thoracic endografts may be different from abdominal endografts since it may involve upward rather than downward movement of the graft. Computational methods can enhance the understanding of the magnitude and orientation of the loads experienced in vivo by thoracic aortic endografts and therefore improve their design and performance. J Endovasc Ther. 2009;16:350-358
引用
收藏
页码:350 / 358
页数:9
相关论文
共 50 条
  • [41] Endovascular treatment of thoracic aortic aneurysms with a short proximal landing zone using scalloped endografts
    Alsafi, Ali
    Bicknell, Colin D.
    Rudarakanchana, Nung
    Kashef, Elika
    Gibbs, Richard G.
    Cheshire, Nicholas J.
    Jenkins, Michael P.
    Hamady, Mohamad
    JOURNAL OF VASCULAR SURGERY, 2014, 60 (06) : 1499 - 1506
  • [42] Advanced Techniques in Thoracic Endovascular Aortic Repair: Chimneys/Periscopes, Fenestrated Endografts, and Branched Devices
    Al-Hakim, Ramsey
    Schenning, Ryan
    TECHNIQUES IN VASCULAR AND INTERVENTIONAL RADIOLOGY, 2018, 21 (03) : 146 - 155
  • [43] Official report of the French Health Authority on thoracic aortic endografts:: Will the rest of the world be influenced by the French?
    Bergeron, P.
    Corbillon, E.
    Amor, M.
    Becquemin, J. P.
    Boyer, L.
    Cardon, J. M.
    Dupont, M.
    Fabiani, J. N.
    Glock, Y.
    Heautot, J. F.
    Kretz, J. G.
    Laskar, M.
    Long, A.
    Marty, M.
    Rieu, R.
    Rousseau, H.
    Vialard, V.
    Pouille, A. I.
    Pages, F.
    Dancoisne, A.
    Lefevre, M.
    Gay, J.
    JOURNAL OF ENDOVASCULAR THERAPY, 2007, 14 : I3 - I4
  • [44] Attachment Site Curvature of Thoracic Endografts is Correlated to Adjacent Aortic Wall Stress and Stress Distribution
    Couper, Nathan
    Richards, Michael
    Chandra, Ankur
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2014, 34
  • [45] Use of Combined Thoracic and Abdominal Endografts for Proximal Severe Neck Angulation in Abdominal Aortic Aneurysms
    Silingardi, Roberto
    Lauricella, Antonio
    Tasselli, Sebastiano
    Borsari, Giulia Trevisi
    Sasha, Njila Mistral Klend
    Coppi, Gioacchino
    JOURNAL OF ENDOVASCULAR THERAPY, 2012, 19 (04) : 517 - 524
  • [46] A mathematical model to predict the in vivo pulsatile drag forces acting on bifurcated stent grafts used in endovascular treatment of abdominal aortic aneurysms (AAA)
    Morris, L
    Delassus, P
    Walsh, M
    McGloughlin, T
    JOURNAL OF BIOMECHANICS, 2004, 37 (07) : 1087 - 1095
  • [47] The magnitude of lift forces acting on drops and bubbles in liquids flowing inside microchannels
    Stan, Claudiu A.
    Ellerbee, Audrey K.
    Guglielmini, Laura
    Stone, Howard A.
    Whitesides, George M.
    LAB ON A CHIP, 2013, 13 (03) : 365 - 376
  • [48] The Biomechanical Analysis of Magnitude and Direction of Force by Different Techniques of Thoracic Spinal Manipulation
    Joo, Sunghee
    Kim, Junghyun
    Lee, Yongwoo
    Song, Changho
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [49] Differences in the magnitude and direction of forces during a submaximal matching task in hemiparetic subjects
    Mercier, C
    Bertrand, AM
    Bourbonnais, D
    EXPERIMENTAL BRAIN RESEARCH, 2004, 157 (01) : 32 - 42
  • [50] Differences in the magnitude and direction of forces during a submaximal matching task in hemiparetic subjects
    Catherine Mercier
    Anne Martine Bertrand
    Daniel Bourbonnais
    Experimental Brain Research, 2004, 157 : 32 - 42