Fascicular anatomy of human femoral nerve: Implications for neural prostheses using nerve cuff electrodes

被引:65
作者
Gustafson, Kenneth J. [1 ,2 ]
Pinault, Gilles C. J. [2 ,3 ]
Neville, Jennifer J. [4 ]
Syed, Ishaq [4 ]
Davis, John A., Jr. [5 ]
Jean-Claude, Jesse [2 ,3 ]
Triolo, Ronald J. [2 ,5 ]
机构
[1] Case Western Reserve Univ, Dept Biomed Engn, Ctr Neural Engn, Cleveland, OH 44106 USA
[2] Louis Stokes Cleveland Dept Vet Affairs Med Ctr, Cleveland, OH USA
[3] Case Western Reserve Univ, Dept Surg, Cleveland, OH 44106 USA
[4] Case Western Reserve Univ, Sch Med, Cleveland, OH 44106 USA
[5] Case Western Reserve Univ, Dept Orthoped, Cleveland, OH 44106 USA
基金
美国国家卫生研究院;
关键词
fascical map; femoral nerve; functional electrical stimulation; nerve cuff electrode; nerve morphology; neuroanatomy; rehabilitation; spinal cord injury; standing; surgical anatomy; FUNCTIONAL ELECTRICAL-STIMULATION; IMPLANTED NEUROPROSTHESIS; EXTREMITY NEUROPROSTHESIS; RECRUITMENT PROPERTIES; SYSTEM; SELECTIVITY; PARAPLEGIA; QUADRICEPS; ACTIVATION; TRANSFERS;
D O I
10.1682/JRRD.2008.08.0097
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Clinical interventions to restore standing or stepping by using nerve Cuff stimulation require a detailed knowledge of femoral nerve neuroanatomy. We harvested eight femoral nerves with all distal branches and characterized the branching patterns and diameters. The fascicular representation of each distal nerve was identified and traced proximally to create fascicle maps of the compound femoral nerve in four cadaver specimens. Distal nerves were consistently represented as individual fascicles or distinct groups of fascicles in the Compound femoral nerve. Branch-free length of the compound femoral nerve was 1.50 +/- 0.47 cm (mean +/- standard deviation). Compound femoral nerve cross sections were noncircular with major and minor diameters of 10.50 +/- 1.52 mm and 2.30 +/- 0.63 mm, respectively. In vivo intraoperative measurements ill six Subjects were consistent with cadaver results. Selective stimulation of individual Muscles innervated by the femoral nerve may therefore be possible with a single neural prosthesis able to selectively stimulate individual groups of fascicles.
引用
收藏
页码:973 / 984
页数:12
相关论文
共 33 条
[1]  
AIZAWA Y, 1992, Okajimas Folia Anatomica Japonica, V69, P35
[2]  
Akers J M, 1997, IEEE Trans Rehabil Eng, V5, P207, DOI 10.1109/86.593301
[3]   Selectivity of multiple-contact nerve cuff electrodes: A simulation analysis [J].
Choi, AQ ;
Cavanaugh, JK ;
Durand, DM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (02) :165-172
[4]  
Davis JA, 2001, J REHABIL RES DEV, V38, P609
[5]  
Davis JA, 2001, CLIN ORTHOP RELAT R, P237
[6]   Standing After Spinal Cord Injury With Four-Contact Nerve-Cuff Electrodes for Quadriceps Stimulation [J].
Fisher, Lee E. ;
Miller, Michael E. ;
Bailey, Stephanie N. ;
Davis, John A., Jr. ;
Anderson, James S. ;
Rhode, Lori ;
Tyler, Dustin J. ;
Triolo, Ronald J. .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2008, 16 (05) :473-478
[7]   RECRUITMENT PROPERTIES OF MONOPOLAR AND BIPOLAR EPIMYSIAL ELECTRODES [J].
GRANDJEAN, PA ;
MORTIMER, JT .
ANNALS OF BIOMEDICAL ENGINEERING, 1986, 14 (01) :53-66
[8]   Quantification of recruitment properties of multiple contact cuff electrodes [J].
Grill Jr., W.M. ;
Mortimer, J.T. .
IEEE Transactions on Rehabilitation Engineering, 1996, 4 (02) :49-62
[9]  
Grill WM, 2000, J BIOMED MATER RES, V50, P215
[10]   Fascicular Perineurium Thickness, Size, and Position Affect Model Predictions of Neural Excitation [J].
Grinberg, Yanina ;
Schiefer, Matthew A. ;
Tyler, Dustin J. ;
Gustafson, Kenneth J. .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2008, 16 (06) :572-581