Application of time-frequency analysis to somatosensory evoked potential for intraoperative spinal cord monitoring

被引:36
作者
Hu, Y [1 ]
Luk, KDK [1 ]
Lu, WW [1 ]
Leong, JCY [1 ]
机构
[1] Univ Hong Kong, Dept Orthopaed Surg, Hong Kong, Hong Kong, Peoples R China
关键词
D O I
10.1136/jnnp.74.1.82
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To investigate the improvement in the reliability of intraoperative spinal cord monitoring by applying time-frequency analysis to somatosensory evoked potentials (SEP). Methods: 34 patients undergoing scoliosis surgery were studied. SEP were recorded during different stages of scoliosis surgery. Averaged SEP signals were analysed intraoperatively by short time Fourier transform (STFT). The time-frequency characteristics of SEP were observed during surgery. The main peak in the time-frequency interpretation of SEP was measured in peak time, peak frequency, and peak power. The changes in these variables were compared with the changes in latency and amplitude during different surgical stages. Results: During different surgical stages, changes in peak times and peak powers were found to correlate with the changes in latency and amplitude, respectively. Peak time showed more variability than latency (p < 0.01), while peak power showed less variability than amplitude (p < 0.0 1). The peak frequency of SEP appeared to be unchanged during surgery. SEP signals were found to have specific time-frequency characteristics, with the time-frequency distribution of the signals being located in a particular time-frequency space. Conclusions: Time-frequency analysis of SEP waveforms reveals stable and easily identifiable characteristics. Peak power is recommended as a more reliable monitoring parameter than amplitude, while peak time monitoring was not superior to latency measurement. Applying time-frequency analysis to SEP can improve the reliability of intraoperative spinal cord monitoring.
引用
收藏
页码:82 / 87
页数:6
相关论文
共 20 条
[1]   Detection of neurological injury using time-frequency analysis of the somatosensory evoked potential [J].
Braun, JC ;
Hanley, DF ;
Thakor, NV .
EVOKED POTENTIALS-ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1996, 100 (04) :310-318
[2]   SPECTRO-TEMPORAL REPRESENTATIONS AND TIME-VARYING SPECTRA OF EVOKED-POTENTIALS - A METHODOLOGICAL INVESTIGATION [J].
DEWEERD, JPC ;
KAP, JI .
BIOLOGICAL CYBERNETICS, 1981, 41 (02) :101-117
[3]   QUESTIONS REGARDING THE SEQUENTIAL NEURAL GENERATOR THEORY OF THE SOMATOSENSORY EVOKED-POTENTIAL RAISED BY DIGITAL FILTERING [J].
EISEN, A ;
ROBERTS, K ;
LOW, M ;
HOIRCH, M ;
LAWRENCE, P .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1984, 59 (05) :388-395
[4]   Multichannel wavelet-type decomposition of evoked potentials: Model-based recognition of generator activity [J].
Geva, AB ;
Pratt, H ;
Zeevi, YY .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (01) :40-46
[5]   Comparison of time-frequency analysis techniques in intraoperative somatosensory evoked potential (SEP) monitoring [J].
Hu, Y ;
Luk, KD ;
Lu, WWJ ;
Leong, JCY .
COMPUTERS IN BIOLOGY AND MEDICINE, 2002, 32 (01) :13-23
[6]   Prevention of spinal cord injury with time-frequency analysis of evoked potentials: an experimental study [J].
Hu, Y ;
Luk, KDK ;
Lu, WW ;
Holmes, A ;
Leong, JCY .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2001, 71 (06) :732-740
[7]   AUTOMATED SPINAL-CORD MONITORING FOR SPINAL SURGERY [J].
IMAI, M ;
HARADA, Y ;
ATSUTA, Y ;
TAKEMITSU, Y ;
IWAHARA, T .
PARAPLEGIA, 1989, 27 (03) :204-211
[8]  
Kostyunina M B, 1996, Neurosci Behav Physiol, V26, P340, DOI 10.1007/BF02359037
[9]   Variability of somatosensory-evoked potentials in different stages of scoliosis surgery [J].
Luk, KDK ;
Hu, Y ;
Wong, YW ;
Leong, JCY .
SPINE, 1999, 24 (17) :1799-1804
[10]  
Noss RS, 1996, EVOKED POTENTIAL, V100, P453