Changes in optically stimulated luminescent dosimeter (OSLD) dosimetric characteristics with accumulated dose

被引:95
作者
Jursinic, Paul A. [1 ]
机构
[1] W Michigan Canc Ctr, Kalamazoo, MI 49007 USA
关键词
optically stimulated luminescent dosimeters; in vivo dosimetry; thermoluminescent dosimeters; diodes; HIGH-ENERGY PHOTON; RADIATION ONCOLOGY; AL2O3-C DOSIMETERS; ELECTRON-BEAMS; RADIOTHERAPY; THERMOLUMINESCENCE; ALPHA-AL2O3-C; DEPENDENCE; IRRADIATION;
D O I
10.1118/1.3267489
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A new type of in vivo dosimeter, an optically stimulated luminescent dosimeter (OSLD), has now become commercially available for clinical use. The OSLD is a plastic disk infused with aluminum oxide doped with carbon (Al(2)O(3):C). Crystals of Al(2)O(3):C, when exposed to ionizing radiation, store energy that is released as luminescence (420 nm) when the OSLD is illuminated with stimulation light (540 nm). The intensity of the luminescence depends on the dose absorbed by the OSLD and the intensity of the stimulation light. The effects of accumulated dose on OSLD response were investigated. Methods: The OSLDs used in this work were nanodot dosimeters, which were read with a MicroStar reader (Landauer, Inc., Glenwood, IL). Dose to the OSLDs was delivered by 6 MV x rays and gamma rays from Co-60 and Ir-192. The signal on the OSLDs after irradiation is removed by optical annealing with a 150 W tungsten-halogen lamp or a 14 W compact fluorescent lamp was investigated. Results: It was found that OSLD response to dose was supralinear and this response was altered with the amount of accumulated dose to the OSLD. The OSLD response can be modeled by a quadratic and an exponential equation. For accumulated doses up to 60 Gy, the OSLD sensitivity (counts/dose) decreases and the extent of supralinear increases. Above 60 Gy of accumulated dose the sensitivity increases and the extent of supralinearity decreases or reaches a plateau, depending on how the OSLDs were optically annealed. With preirradiation of OSLDs with greater than 1 kGy, it is found that the sensitivity reaches a plateau 2.5 folds greater than that of an OSLD with no accumulated dose and the supralinearity disappears. A regeneration of the luminescence signal in the dark after full optical annealing occurs with a half time of about two days. The extent of this regeneration signal depends on the amount of accumulated dose. Conclusions: For in vivo dosimetric measurements, a precision of (0.5% can be achieved if the sensitivity and extent of supralinearity is established for each OSLD and use. Methods are presented for accomplishing this task. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3267489]
引用
收藏
页码:132 / 140
页数:9
相关论文
共 44 条
[1]   Optically stimulated luminescence and its use in medical dosimetry [J].
Akselrod, M. S. ;
Botter-Jensen, L. ;
McKeever, S. W. S. .
RADIATION MEASUREMENTS, 2006, 41 :S78-S99
[2]  
AKSELROD MS, 1990, RADIAT PROT DOSIM, V32, P15
[3]  
AKSELROD MS, 1993, RADIAT PROT DOSIM, V47, P159
[4]   A radiation dosimetry method using pulsed optically stimulated luminescence [J].
Akselrod, MS ;
McKeever, SWS .
RADIATION PROTECTION DOSIMETRY, 1999, 81 (03) :167-176
[5]   DEEP TRAPS IN HIGHLY SENSITIVE ALPHA-AL2O3C TLD CRYSTALS [J].
AKSELROD, MS ;
GORELOVA, EA .
NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 21 (01) :143-146
[6]   Thermal quenching of F-center luminescence in Al2O3:C [J].
Akselrod, MS ;
Larsen, NA ;
Whitley, V ;
McKeever, SWS .
JOURNAL OF APPLIED PHYSICS, 1998, 84 (06) :3364-3373
[7]  
ALLEN P, 1990, RADIAT PROT DOSIM, V33, P19
[8]   AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams [J].
Almond, PR ;
Biggs, PJ ;
Coursey, BM ;
Hanson, WF ;
Huq, MS ;
Nath, R ;
Rogers, DWO .
MEDICAL PHYSICS, 1999, 26 (09) :1847-1870
[9]  
ANDERSEN CE, 2002, INT S STAND CO UNPUB
[10]  
Attix F.H., 1986, Introduction to Radiological Physics and Radiation Dosimetry, P395